switch surf pvc 1g interm 10a

Surface Switch, 1 Gang, 250VAC, 10A, Intermediate

Catalogue Number: 56SW110/I
switch surf pvc 1g interm 10a
Colour: Grey
Colour: Per UOM Std.
  • Chemical Grey 1 PCE
  • Grey 1 PCE
  • Resistant Orange 1 PCE
  • Resistant White Electric 1 PCE

Specifications

hide show
Range of product
Series 56
Range
Clipsal - 56 Series
Product brand
Clipsal
Product or component type
switch
Device presentation
basic element with full cover plate
Device application
control
Colour
cover: grey
Handle colour
grey
Suitability for isolation
no
Switch function
1-pole
Poles description
1P
Control type
rotary knob
Number of poles
1
Device mounting
surface
Fixing mode
by screws
Material
PC (polycarbonate)
Tightening torque
0.8 N.m
Local signalling
without
[Ue] rated operational voltage
250 V AC 50 Hz
Rated current
10 A
Breaking capacity
10 kA
Motor M-rating AS3133
M80 at 250 V
Rotary handle padlocking
2 padlocks 8-8 mm
Marking
ON-OFF
Marking location
marking on surface
Height
107 mm
Width
101 mm
Depth
83 mm
Net weight
0.48 kg
Targeted country
Australia
Market segment
  • utility
  • industry
  • small commercial
    • Ambient air temperature for operation
      -25-75 °C
      IP degree of protection
      IP66 conforming to AS 60529
      Standards
      AS/NZS 3133
      Sustainable offer status
      Green Premium product
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120809EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Technical Data Catalogues

      • Product Environmental

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the replacement for 56SW110N?

      We need to build this up, use 56SW110 + 56LEDK1.
       

      What is the part number for an indication LED for the 56SW110?

      The part number for an indication LED for the 56SW110 is - 56LEDK1

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56LEDK1
      User-added image

      Is there a replacement mechanism for the 56SW110 switch?

      No, we do not offer replacement mechanisms for 56 series switches because it may affect the IP rating.

      For further information please visit  https://www.clipsal.com/Trade

      How do I get a 56 Series Double outlet?

      56E4 (4 Gang Base) + 56SO310LE (socket outlet) X2 + 56SW110LE (Switch) X2

      Is the switch mec available as a spare part for the 56SW110?

      Yes, the code is PDL581/58YL.

      Is there a lockable version or key lock version for the PDL 56SW120GY

      Yes, you can use 56SWK120GY or a 56SW2K120GY (Key Removable in both position)

      What is the part number for a 2-way industrial switch?

      There are 2 options.
      1. The Wilco Metal Clad Series WMS110-TW, 10A, 2-WAY, single pole
      2. The 56 Series 56SW110/2, 10A, 2-WAY, single pole

      Are there a choice of labels with the PDL 56SW120CO range

      Yes the units come with stickers

      Is there a 3 position 56 series switch (On - Off - On)?

      We have the 56 series change over switches:
      56SW120CO - S.P. 20A Changeover
      56SW320CO - T.P. 20A Changeover
      56SW332CO - T.P. 32A Changeover
      Also the Forward/Reverse switch:
      56SW320FR - S.P. or T.P. 20A forward/reverse

      What is the neon to fit the PDL 56SW110?


      The 56LEDK1 is the neon kit to use. It includes the drill bit and any other parts needed to fit the LED. Visit pdl.co.nz for the datasheet, installation sheet and further information.
       

      What is the part number for a PDL 56 Series switch with a 10amp changeover

      It is not available in 10amp version, you can use PDL 56SW120CO which is a 20 amp version.

      Is the PDL 56SWK110 lockable in the on position

      No - it is only lockable in the off

      Can I get a 56C310 with key lock switch?

      Does the PDL 56SWK110 have key removable in both positions?

      No the Key is only removable in the Off Position.
      For key removable in both on and off positions you need PDL56SW2K110

      What is a 32A inductive isolator for an induction cook top

      Part number PDL 56SW150

      What is the part number for a 56SW320CX in orange?

      The part number for a 56SW320CX in orange is 56SW320CX-RO.

      Is there a 56 series 10amp switch for 2 way switching?

      Yes, refer to the following part name: 56SW110/2-GY

      What size cable/ conductor can a 56SW120 take?

      The 56SW120 isolator switch accepts a cable/ conductor size of a minimum of 2.5mm² and a maximum 16mm².

      Is the PDL 56SW120 available change over with spring return

      Not available in the 56 series range

      What is a 56 Series forward / reverse switch?

      A PDL 56SW320FR

      What is the AC3 rating of a PDL 56SW363/2

      The AC3 rating is 18.5kw, 35A

      Does EY56SW110 come with enclosure ?

      yes it does 

      What is the neon to fit the PDL 56SW120

      Use the 56LEDK1 which includes the drill bit and everything needed to fit the LED

      What is the 56 Series intermediate switch with on/on indication

      Part number 56SW1102I

      PDL56SW1102ILEGY
      PDL56SW1102ILERO
      PDL56SW1102ILERW
       

      Is the PDL56SW110I available in 16amp

      Not available but you can use a PDL56MO500/1 with PDL 600 series mechs

      What is the part number for a 56 switch 1ph 10amp, key removable both positions

      PDL56SW2K110LEGY     56SW2K110 GREY (LE) PDL
      PDL56SW2K1102LEGY   56SW2K110/2 GY (LE) PDL
      PDL56SW2K120LEGY     56SW2K120 GREY (LE) PDL
      PDL56SW2K132LEGY     56SW2K132 GREY (LE) PDL
      PDL56SW2K320LEGY     56SW2K320 GREY (LE) PDL
      PDL56SW2K332LEGY     56SW2K332 GREY (LE) PDL
      PDL56SW2KC1102LEGY 56SW2KC110/2 GY COMM-KEY PDLM
      PDL56SW2KC132LEGY   56SW2KC132 GY COMM-KEY LE PDL
      PDL56SW2KC220LEGY   56SW2KC220 (LE) COMM-KEY PDLM
      PDL56SW2KC320LEGY   56SW2KC320 GY COMM-KEY LE PDL
      PDL56SW2KC332LEGY   56SW2KC332 GY COMM-KEY LE PDL




       

      What is the IP rating for a PDL 56SO310GY

      The IP rating is IP66

      Does the 96VH110/2 have a sensitivity adjustment

      No it does not only the 100SA360, 750WP and 750WPR do

      What is the 56C310 with an RCD attached?

      Part No.: 56SC310RC

      Is there an IP66 Change over switch 20A?

      Yes 56SW220CO is IP66.

      Is the 56SW420CO able to be locked in both positions ?

      There is a hole to lock in one position , if there is a need to lock in both positions the switch can be drilled to have a hole to lock in both positions..

      Is the PDL 56SW320CO a 2 or 3 position

      It is a double throw with centre off

      Can you get a PDL 56 series switch with a common key?

      YES :
      56SWKC110, 56SWKC120, 56SWKC320, 56SWKC332
      56SW2KC1102, 56SW2KC132, 56SW2KC220, 56SW2KC320, 56SW2KC332

       

      Do you have a 56SO310 that is auto switched?

      Yes, we do  have a 56SO310 that is auto switched. The part number is 56SO310A.

      Is there a replacement for a PS110 Protected die-cast switch?

      The closest alternative is is RPSW110M.

      Is there an intermediate mech in the 56 Series?

      There are two intermediate mechs in the 56 Series - 56SSW10/I-GY and the 56SW110/I-GY.

      What is the part number for a 56 series 15amp 240V 1 pole isolator with neon?

      The part number for a 56 series 15amp 240V 1 pole isolator with neon is - 56SW115 & 56LEDK1

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56SW115
      https://www.clipsal.com/Trade/search-results?q=56LEDK1
      User-added image

      Is there a PDL 56SW120 with a neon indicator?

      Not built as a standard product but you can use a PDL56LEDK1 to add an LED indicator to any 56 series switch.



       

      Does Clipsal sell just the flap only of the RCD part of the 56SC510RC?

      No, we dont sell just the flap as spare. 
      try 56CB4N - its a DIN Rail Accessory Mounting Kit.

      Please click this link for more information
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56CB4N

      User-added image
       

      What is the part number for a 56 series 1 pole 20amp isolator?

      The part number for a 56 series 1 pole 20amp isolator is - 56SW120

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56SW120
      User-added image

      What is the part number for a lockable , when in the OFF position , switched outlet , 3 pin 10amp with common key?

      The part number for a lockable , when in the OFF position , switched outlet , 3 pin 10amp with common key is - 56E2 , 56SO310LE & 56K1SW115CKL
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E2
      https://www.clipsal.com/Trade/search-results?q=56SO310LE
      https://www.clipsal.com/Trade/search-results?q=56K1SW115CKl
       

      What is the part number for a 56 series keyed 10amp switched outlet?

      The part numbers for a 56 series keyed 10amp switched outlet are - 56E2 , 56SO310LE & 56K2SW115LE

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E2
      https://www.clipsal.com/Trade/search-results?q=56SO310LE
      https://www.clipsal.com/Trade/search-results?q=56K2SW115LE
      User-added image
      User-added image

      User-added image
       

      What are the part numbers to make up a 56 series 3 flat pin 10amp outlet with RCD protection and LED indication?

      The part numbers to make up a 56 series 3 flat pin 10amp outlet with RCD protection and LED indication are - 56E3 , 56SO310LE & 56CB4N

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E3
      https://www.clipsal.com/Trade/search-results?q=56SO310LE
      https://www.clipsal.com/Trade/search-results?q=56CB4N
      User-added image
      User-added image

      User-added image

      What are the part numbers for a 56 series 4 gang base with 10 & 15amp socket outlets with RCD protection?

      The part numbers for a 56 series 4 gang base with 10 & 15amp socket outlets with RCD protection are - 56E4 , 56SO310LE , 56SO315LE & 56CB4N

      For further information , visit links below:-
      https://www.clipsal.com/Trade/search-results?q=56E4
      https://www.clipsal.com/Trade/search-results?q=56SO310LE
      https://www.clipsal.com/Trade/search-results?q=56SO315LE
      https://www.clipsal.com/Trade/search-results?q=56CB4N
      User-added image

      User-added image
      User-added image