cap protective 1ph plug

Protective PIN Cap

Catalogue Number: 56PC2
cap protective 1ph plug
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
  • Resistant Orange 1 PCE

Specifications

hide show
Range of product
Series 56
Range
Clipsal - 56 Series
Product brand
Clipsal
Product or component type
plug cap
Accessory / separate part category
fixing accessory
Material
polycarbonate
Height
66 mm
Width
66 mm
Depth
56 mm
Net weight
0.06 kg
Targeted country
Australia
Market segment
  • industry
  • small commercial
  • utility
    • Ambient air temperature for operation
      -25-75 °C
      IP degree of protection
      IP66
      Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP121020EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Does the bridge for PDL 56PE2 come with the product

       Yes it does

      Can you buy a 56PB2 without a lable

      No

      What is the cap for a 56CSC310?

      56SC2

      Can a 56PB2 be mounted horizontally (face up) in a wet area?

      It is not recommended if there is another option as the IP66 rating doesn't allow for immersion in water, which is what happens if water pools in the lid.

      What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

      Product Line:
      Circuit Breakers

      Environment:
      Electrical Distribution Equipment

      Resolution:
      The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

      Is part number 56/32 pad lockable?

      Yes part number 56/32 can be pad lockable.

      What is the largest cable size for the PDL 56P420 plug?

      The largest cable size for the 56P420 plug is 16.4mm

      Will a PDL 56P420 fit into a PDL56SO520

      Yes it does

      What is the smallest round pin plug in the 56 series

      The smallest is the 56P320

      Is the 563L2 still available?

      Yes, the 563L2 is still part of our range.

      Some of the key features are:
      • 3 cables
      • Grey insulated
      • Extended

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=563L2





       

      Do you do the 56P532 and the 56CSC532 in grey?

      The 56P532 is available in grey the 56CSC532 is not available in grey.

      Is 56PMK pole mounting bracket kit supplied with 56F16/30NOTM?

      Yes, 56PMK pole mounting bracket kit is supplied with 56F16/30NOTM.

      For further information, please visit the following links:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56F16/30NOTM
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56PMK

      Is part number 56/32 available in single gang?

      No. Unfortunately, part number is not available as single.

      Can I get a 56JB2 with a clear lid?

      No, but you can get a clear lid separately.
      The part number is 56L2-TR.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56L2

      Can I get a replacement flap for a 56RC?

      No, unfortunately we don't have spare flaps. However you could use a 56SOCOVER.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SOCOVER

       

      What is the 56 Series box for flush mounting PDL 56E2 enclosure

       PDL 56FA2

      Is the centre pin a guide for the PDL 56P532

      The PDL 56P532 the centre pin is a neutral not a guide
      3 phases Neutral and Earth

      Does Clipsal have the 56PB, enclosure only?

      Yes, you just get a 56E1 and a 56L1.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56E1 
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56L1/22 



       

      Do you have an IP56 pendant outlet?

      Yes you can use a 56PEK and add the 56 series switch and socket outlet.

      Can I get a spare key for the PDL 568CK (Common Key Version)

      We do not supply spare keys, but you can ask any locksmith to cut a garage key code 60121.

      Is there a master key for the 568 series

      No there is not, if you want the keys to be the same you need to order the common key version PDL 568CK

      Do you do a 56/32 with one spot for a 30 mech not two?

      No unfortunately we dont make that part you would need to place a 30P to fill one of the holes.

      Does the PDL 56FA2 come with a flush box

      No, it comes with a gasket and metal mounting plate to fix to the surface to make the switch / socket flush

      What is the part number of the mounting enclosure/ backbox supplied with 56PB, IP66 start control station?

      56ES1 is the part number  of the mounting enclosure/ back box supplied with 56PB, IP66 start control station.

      Key Features

      • 1 gang shallow
      • 1 x 25 mm, 1 x 20 mm conduit entries
      • Dimensions 101 x 101 x 38mm high
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56ES1

      Are the 56 Series Mactro plugs and connectors available in chemical resistant materials

      Yes, for chemically resistant orange Valox the codes are 56PV, 56PAV, or 56CRV. Add 5% to standard trade prices for Valox versions.

      Does a 56 series plug keep its IP rating when it is unplugged?

      Only if it has a cover on it (56PC is the cover for 16-50A plugs)
      When the plug is unplugged from a socket or cord connector the pins are exposed so it has no IP rating

      What is the part number for a lid/cover for the 56ES2?

      The part number for a lid/cover for the 56ES2 is - 56L2
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56L2
      User-added image

      Is there one gang vesion of 56/32 adaptable enclosure to take 30 series mechanisms?

      Unfortunately not. We do not have one gang version of 56/32. The unused gang can be blanked off using 30P, blanking mechanism.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56/32
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30P

      what is the code for a 56 series 3 phase 32A plug with phase and neutral

      56P532 (STRAIT)
      56PA532 (ANGLED)

      What are part numbers for push button & contact block to suit 56PB?

      The push button part number is ZB5AA3

      Contact Block part number is ZB5AZ101

      Is pole mounting bracket supplied with 56F16/30, consumer terminal box?

      Yes, 56PMK pole mounting bracket kit is supplied with 56F16/30.

      For further information, please visit the following links:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56F16/30NOTM 
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56PMK

      What is part number for 3 Phase pendant outlet to suit 56P315?

      Part number 56POK is used with 3 phase 15amp plug.
       

      What is the part number for a 56C310 with a deep base?

      The part number for a 56C310 with deep base is - 56ED2 & 56C310LE

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56ED2
      https://www.clipsal.com/Trade/search-results?q=56C310LE
      User-added image

      What is the maximum cable size for a 56P520?

      The maximum conductor size for a 56P520 is 4mm sq with a maximum cable diameter of 15.7mm

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P520
       

      Does the flush surround 56FA2 work with the Easy 56 Series as well as the standard 56 Series?

      Yes the flush surround 56FA2 does work with the Easy 56 Series as well as the standard 56 Series?
      Some of the key features are:
      • Enclosures and Boxes
      • Flush surround suits 2 Gang 56 Series (157 x 254mm).
      • Temperature range -25C to +75C.
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2


       

      What is the part number for a 56P532 angled internal?

      The part number for a 5pin 32A angled internal pin housing is 56PA532G.

      Some of the key features are:
      • Internal pin housing
      • 5 Round pins
      • 2.5-16 sq mm Conductor terminal
      • Polyester housing
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56PA532G
       

      Can I suspend a 56 Series cord connector?

      Yes. Select the required size suspension hook to match the size of the connector. Fit the hook between the body of the connector and the cord clamp.

      56POK FOR 10 TO 15AMP
      56SHM FOR MACTRO 16 TO 20AMP
      56SHKL FOR MACTRO LARGE 32 TO 50AMP

       

      What IP66 enclosure can be used for 30 series mechs?

      Part no 56/32 has IP66 rating and can be used for

      30 series mechs

      Is there a 56 series outlet to suit a 56P432 that restricts the plug from being removed when switched on?

      Yes, use of the 56CVI432 series will restrict removal while the outlet is switched on as there is an interlocking pin to hold the plug in place.
       
      Some of the key features are:
      • 32 A thermal current
      • Internal interlock switch
      • 4 round pins
      • 500V
      • IP66
      • 3 Pole
      • Vertical
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56CVI432 


       

      What is the operating temperature of the 563/1 and the 563/2 1 and 2 screw bluepoints?

      Our connectors are made of Polypropylene (which is a flame retardant material) according to the supplier this material can hold up top +-165C.
      Although I will not recommend more than room temperature + 40C.
      Keep in mind cables will not stand such temperature anyway as they normally rated between 75C to 90C

      Some of the key features are:
      • Cable Connectors
      • Single or double screw
      • Clear insulated
      • Suits up to 2 x 6mm² cables


       

      What is the part number for a protective rubber boot to suit the 56PB?

      The protective Rubber boot to suit the 56PB is a ZBPA. This is from the Schneider product range of push buttons . The 56 series push buttons utilise the Schneider ZB series of push buttons and contact blocks.
      For information regarding the ZBPA please follow the link provided .
      https://www.schneider-electric.com.au/en/search/zbpa
      User-added image

      What is the part number for the replacement internal pins for the 56P532?

      The part number for the replacement internal pins for the 56P532 is - 56PA532G

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56PA532G

      User-added image

      In the 56 series will 56P510, 5 pin, 500V, 10A plug fit into 56SO532, 5 pin, 500V, 32A socket?

      Unfortunately not, 56P510 cannot be plugged into 56SO532 as 56P510 is a size 1 plug. 56P532 is the recommended plug to use with 56SO532.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P532

      How to configure the SRC 5,6,8 & 10 KVA UPS Models External Battery Packs using the LCD display

      Issue:

      Configuration of SRC battery packs via the LCD display

      Product Line:

      Smart-UPS Online

      Environment:

      All SRC models, All Serial Numbers

      Cause:

      Batteries need to  be manually added to the UPS in order for the unit to properly calculate runtime

      Resolution:
       

      Procedure for Configuring the number of battery strings through the display interface or LCD menus:


      1. Press the Enter key to select the main menu.

      2. Scroll down to configuration.

      3. Press the enter key to select configuration. 

      4. Scroll down to battery setup by number of battery pack. 

      5. Enter the correct number of attached battery packs.


      In order to setup the external battery packs, please key in as (Ah of battery) x (total number of batteries).

      Example 1:   If there are 16pcs of 5Ah battery in series (for 5kVA), the total Ah number is 5Ahx16pcs=80Ah.
      Example 2:   If there are 16 pcs of 100 AH batteries in series(for 5 KVA), the total AH number is 100 AH x 16 pcs=1600 AH
      Example 3:   If there are 2 strings of 16pcs of 5Ah battery in series (for 5kVA), the total Ah number is 5Ahx16pcsx2 strings=160Ah.
        
      The 80Ah inside the table is the default setting for 5kVA/6kVA (1 EXB: 16pcs of 5Ah battery)
      The default setting for 8kVA is 140Ah (1 EXB: 20pcs of 7Ah battery)
      The default setting for 10kVA is 180Ah (1 EXB: 20pcs of 9Ah battery).
        
      If “Ext total battery Ah” is set as 0, it means there is no external battery connected. 
       
              

      "

      What is the part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base??

      The part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base is - 56FA2 & 56FA2B
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56FA2
      https://www.clipsal.com/Trade/search-results?q=56FA2B

      User-added image
      User-added image

      What is the part number of the flush surround to suit 56CV, one piece cover, switched outlets?

      56FA2 is the part number of the flush surround to suit 56CV, one piece cover switched outlets. Surface mounted 56 Series Sockets, Switches and Combinations can be transformed into flush mounting equivalents using the 56FA Surrounds and Brackets. The surrounds can be used on various types of walls to ensure a neat installation, such as:
      • a mounting enclosure (back box) in poured concrete
      • a bracket on brick, brick veneer or panel walls.
      The brackets provide the installer with a  practical method of flush mounting 56 Series accessories. Comprehensive installation instructions are supplied with all units.
      56FA1, 56FA2, 56FA3 and 56FA4 Flush Surrounds contain a moulded flange, foam gasket and stainless steel mounting screws.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2

      What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (US only)?

      The CAGE codes for Schneider Electric/SQUARE D are listed below:
      CAGE Code Company Address
      04429 SQUARE D CO LEEDS MFG PLANT 940 MOORE ST NE LEEDS, AL 35094
      05684 SQUARE D CO MIDDLETOWN MFG PLANT 1500 S UNIVERSITY BLVD MIDDLETOWN, OH 45044
      07442 SQUARE D CO DALLAS ASSEMBLY PLANT 1111 REGAL ROW DALLAS, TX 7524
      12670 SQUARE D COELECTROMAGNETIC INDUSTRIES DIV 1410 DONALDSON PIKE B-5 NASHVILLE, TN 37217
      14280 SQUARE D CO LEXINGTON MFG PLANT 1601 MERCER RD LEXINGTON, KY 40511
      14799 SQUARE D CO CHICAGO ASSEMBLY PLANT 9522 W WINONA SCHILLER PARK, IL 60176
      19804 SQUARE D CO GRAND BAY OF BRECKSVILLE 6995 S EDGERTON RD SUITE 100 BRECKSVILLE, OH 44141
      2E203 SQUARE D CO 810 GLEN EAGLE CT SUITE 100 BALTIMORE, MD 21286
      4T466 SQUARE D CO 1010 AIRPARK CENTER DR NASHVILLE, TN 37217
      51917 SQUARE D CO ASHEVILLE MFG PLANT 128 BINGHAM RD ASHEVILLE, NC 28806
      51918 SQUARE D CO AUTOMATION AND CONTROL BUSINESS RALEIGH, NC 27611
      51920 SQUARE D CO COLUMBIA MFG PLANT SUMTER HWY 76 AND 378 COLUMBIA, SC 29209
      55947 SQUARE D CO SORGEL MFG PLANT 4065 N RICHARDS ST MILWAUKEE, WI 53212
      56158 SQUARE D CO OSHKOSH MFG PLANT 3300 MEDALIST DR OSHKOSH, WI 54901
      56302 SQUARE D CO CEDAR RAPIDS MFG PLANT 3700 6TH ST SW CEDAR RAPIDS, IA 52406
      56303 SQUARE D CO 1717 CENTER PARK RD LINCOLN, NE 68512
      56304 SQUARE D CO OXFORD MFG PLANT 5735 COLLEGE CORNER RD OXFORD, OH 45056
      56365 SQUARE D CO CORPORATE OFFICES 1415 S ROSELLE RD PALATINE, IL 60067
      63637 SQUARE D CO MISSOURI MFG PLANT 4800 PARIS RD COLUMBIA, MO 65202
      63831 SQUARE D CO HUNTINGTON PLANT 6 COMMERCIAL RD HUNTINGTON, IN 46750
      70745 SQUARE D CO SENECA PLANT 1990 SANDIFER BLVD SENECA, SC 29678
      88434 SQUARE D CO 13191 CROSSROADS PKY N SUITE 205 LA PUENTE, CA 91746
      88753 SQUARE D CO 3516 CONCORD RD YORK, PA 17402


      Legacy KB System (APS) Data: RESL206488 V1.0, Originally authored by MaTh on 10/26/2011, Last Edited by MaTh on 10/26/2011
      Related ranges: Standards Applied to Power Management PRODUCTS

      What are the UL and IEC ratings for the Merlin Gerin C60 breakers?

      Issue:  
      What standards do Multi 9 C60 breakers conform to? 

      Product Line:
      Multi 9 C60 Breakers 

      Environment:  
      Multi 9 UL and IEC C60 type breakers

      Resolution:
      Ratings per UL Standards     UL 489/CSA C22.2 No.5 C60   UL 489/CSA C22.2 No.5 C60  
            (240 Vac)       (480Y/277 Vac)    
      Number of Poles     1P 1P 2P 3P 1P 2P 3P  
      Rated Current at 77°F (25°C)     0.5–20 A 25–35 A 0.5–35 A 0.5–35 A 0.5–20 A 1–20 A 1–20 A  
          120 V 10 kA 10 kA 10 kA  
        AC 50/60 Hz 240 V 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA  
      Interrupting Ratings   277 V 10 kA 10 kA 10 kA  
      as per UL 489/CSA C22.2 No.5   480Y/277 V 10 kA 10 kA  
        DC 60 V 10 kA 10 kA 10 kA  
          125 V 10 kA  
                           
      Ultimate Breaking Capacity (Icu) AC 50/60 Hz 240 V 10 kA 10 kA 20 kA 20 kA 10 kA 10 kA 10 kA  
      as per IEC 60947-2 Standard   415V 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA  
          440V 6 kA 6 kA 6 kA 6 kA  
      Ratings per UL Standards      UL 1077 C60            
      Number of Poles     1P 2P 3P 4P        
      Rated Current at 77°F (25°C)      0.5–63 A  0.5–63 A  0.5–63 A  0.5–63 A        
          120 Vac 10 kA        
        50/60 Hz 240 Vac 10 kA 10 kA 10 kA 10 kA        
      Interrupting Ratings   277 Vac          
      as per UL 1077   480Y/277 Vac              
          65 Vdc 10 kA        
          125 Vdc 10 kA        
          240 V 10 kA 20 kA 20 kA 20 kA        
      Ultimate Breaking Capacity (Icu) AC 50/60 Hz 415V   10 kA 10 kA 10 kA        
      as per IEC 60947-2 Standard   440V 6 kA 6 kA 6 kA        
                           
      Ratings per IEC 60947-2    N40  C60N  C60H  C60L  C120H
      Number of Poles   1 (Ø + N) 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4
      Rated Current 25°C (77°F) In 1–40 A  1–63 A 1–63 A 1–40 A  1–40 A 1–25 A 1–25 A
      Rated Current (A) 40°C (104°F) In  —  —  —  —  —  —  — 63–125  63–125
      Rated Voltage Ue 230 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V
        130 Vac  —  —  —    —  —  —    —
        230–240 Vac 7.5 kA 10 kA 20 kA 15 kA 30 kA 25 kA 50 kA 15 kA 30 kA
        400–415 Vac 2 kA 3 kA 10 kA 4 kA 15 kA 6 kA 25 kA 4 kA 15 kA
      Ultimate Breaking Capacity (Icu) 440 Vac  —  — 6 kA  — 10 kA  — 20 kA  — 10 kA
      as per IEC 60947-2 Standard 1P 60 Vdc  — 15 kA  — 20 kA  — 25 kA  —  —  —
        2P 125 Vdc  —  — 2P 20 kA  — 2P 25 kA  — 2P 30 kA  —  —
           —  — 3P 30 kA  — 3P 40 kA  — 3P 50 kA  —  —
        3P 250 Vdc  —  — 4P 40 kA  — 4P 50 kA  — 4P 60 kA  —  —

      Do we make a 56DB2 backet as a spare part?

      Unfortunately we do not to this as a spare part. However, it can be ordered as a special.

      Use the order code GCR_56_MISC

      The part number is 56DB2PANEL