PLUG IP66 STR 4PIN
plug ip66 str 4pin rnd 10a qc
PLUG TOP IP66 STR 4PIN 10A 500
PLUG TOP IP66 STR 4PIN 10A 500
PLUG IP66 STR 4PIN
plug ip66 str 4pin rnd 10a qc
PLUG TOP IP66 STR 4PIN 10A 500
PLUG TOP IP66 STR 4PIN 10A 500

Plugs and Extension Sockets, Straight Plugs - IP66, 500V 10A - 4 Round Pins

Catalogue Number: 56P410
PLUG IP66 STR 4PIN
plug ip66 str 4pin rnd 10a qc
PLUG TOP IP66 STR 4PIN 10A 500
PLUG TOP IP66 STR 4PIN 10A 500
PLUG IP66 STR 4PIN
plug ip66 str 4pin rnd 10a qc
PLUG TOP IP66 STR 4PIN 10A 500
PLUG TOP IP66 STR 4PIN 10A 500
Colour: Electric Orange
Colour: Per UOM Std.
  • Electric Orange 1 PCE
  • Grey 1 PCE
  • Resistant Orange 1 PCE

Specifications

hide show
Range
Clipsal - 56 Series
Range of product
Series 56
Product brand
Clipsal
Product or component type
plug
Device application
power supply
[In] rated current
10 A
Poles description
3P + E
[Ue] rated operational voltage
500 V AC 50 Hz conforming to EN 60309-2
Voltage colour
black
Colour
orange (RAL 2004)
Material
plastic
Plug, socket category
low voltage
Material
polycarbonate: housing
Outlet standard
industrial
Connections - terminals
screw terminal 1-6 mm²
Wire stripping length
  • 45 mm
  • 12 mm
    • Contacts material
      pins: brass
      Cable entry
      cable gland
      Thread type
      M25
      Plug, socket, control station shape
      straight
      Pin arrangement
      K
      Duration
      7 h
      Net weight
      0.36 kg
      Height
      78 mm
      Width
      78 mm
      Depth
      167 mm
      Targeted country
      Australia
      Market segment
    • industry
    • small commercial
    • utility
      • Standards
        AS/NZS 3123
        IP degree of protection
        IP66 conforming to AS 60529
        Ambient air temperature for operation
        -25-75 °C
        Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP121020EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • CAD Files and Packs

        • Product Brochures

        • Technical Data Catalogues

        • Installation Instruction

        • Product Environmental

        • Operating Manuals

        • Specifications

        • Certificates (MSDS)

        • Corporate Marketing

        Frequently Asked Questions

        hide show

        Will a 56P210 fit a 56SO210?

        Yes, the 56P210 will plug into the 56SO210.

        For further information please visit https://www.clipsal.com/Trade
         

        What is the largest cable size for the PDL 56P420 plug?

        The largest cable size for the 56P420 plug is 16.4mm

        In the 56 series will 56P510, 5 pin, 500V, 10A plug fit into 56SO532, 5 pin, 500V, 32A socket?

        Unfortunately not, 56P510 cannot be plugged into 56SO532 as 56P510 is a size 1 plug. 56P532 is the recommended plug to use with 56SO532.
        For further information, please visit
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P532

        Will a PDL 56P420 fit into a PDL56SO520

        Yes it does

        Will a 56P310 fit in to a 56SO315

        Yes

        Which 56 Series plug fits the SS15

        Use a PDL 56P310

        What is the cable entry diameter for a PDL 56P310

        Min 7mm and Max 11mm

        Can I get the PDL 56 Series 56P310 in valox orange

        Yes, part number is PDL56PV310RO

        Can I get the 56P310 in white?

        Yes, the 56P310 is available in Resistant White Electric.

        Some of the key features are:
        • 20 mm thread
        • 3 flat pins
        • 1.5 - 6 sq mm conductor terminal
        • M80 motor rating
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P310

         

        What is the smallest round pin plug in the 56 series

        The smallest is the 56P320

        Is the 56SS10 BLACK TEST COVER available as a spare part?

        not available as a spare/separate part

        Does the 56P313 have an in-line fuse

        Yes however this product has been obsolsted in NZ  this was a BS 3 pin rewirable plug

        What is the plug to suit a PDL 56CV516

        Need to use a PDL 56P516 or PDL 56PA516

        What is the cord connector to fit the PDL 56P716 plug

        We do not do one just the socket outlet

        Do you do the 56 series 56SO410 cover in chemical grey?

        No, unfortunately we only do the entire unit in chemical grey.

        The part number would be 56SO410-CG.

        For further information please visit 
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SO410

        What is part no for socket to suit 56P416K

        Part no for socket 56SO416K

        for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SO416K

        User-added image

        Is the 56C310 lockable?

        The 56C310 comes with a locking provision on the flap which will
        allow the part to be locked

        What is the part number for a 56C310 in white?

        The part number for a 56C310 in white is a 56C310-RW

        What is the 56C310 with an RCD attached?

        Part No.: 56SC310RC

        Can the outputs on the VIP410 be customized

        Issue 
        The outputs are pre assigned, but can it be customized.

        Product Line 
        VIP410

        Environment
        Wiring outputs and inputs.

        Cause
        Outputs on the VIP410 need to be customized.

        Resolution




         

        What setting is dusk till dawn for the PDL 56SS10

         The setting is D-D

        Can a PDL 56SS10 handle 2 x 250W metal halide lamps

        No, need to use a contactor for the control

        Can I use a PDL 56SS10 Sunset Switch with metal halide lamps

        Yes, if you put a contactor between them

        what is the part no of 56C310 in woolworths color ?

        the part no is 56C310-WW

        What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

        Product Line:
        Circuit Breakers

        Environment:
        Electrical Distribution Equipment

        Resolution:
        The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

        Can I use an old PDL 56P435 plug with a 56SO440 and 56SO450 socket

        Yes you can plug a 32A(or 35A) plug into a 40A or 50A socket as long as it has the same number of pins or less.

        What is the cord connector to suit PDL 56P310?

        The cord connector part code is PDL56CR310

        Follow the link for details on the product:
        https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=383

        Installation sheet attached.

        What is the part number for a 56C310 with a deep base?

        The part number for a 56C310 with deep base is - 56ED2 & 56C310LE

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=56ED2
        https://www.clipsal.com/Trade/search-results?q=56C310LE
        User-added image

        What is the part number for the part used to suspend 2 x 56C310 switched outlets?

        The part number for the part used to suspend 2 x 56C310 switched outlets is - 56SPOK

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=56SPOK
        User-added image

        Can I use a PDL 56SS10WE to switch MH lighting - will there be any issues

        You need to use PDL 56SS10 with a relay or a Telemecanique K range contactor to switch the load

        What setting is on all night on a 56SS10 Sensor

        D-D = Dusk to dawn
        The load will switch ON at dusk and Switch OFF again at dawn

        Does Clipsal offer 56C310 in double pole?

        Yes, the part name is as follows: 56C310D

        Can a relay failure for the VIP410 be wired to a physical contact?

        Issue 
        Want a contact to operate if the VIP410 has an internal fault.

        Product Line 
        VIP410

        Environment 
        Programming inputs and outputs.

        Cause 
        The device has no protection when an internal fault occurs.

        Resolution 
        Yes it is possible to wire the watchdog to a physical contact.

        For custom operation mode information see article index?page=content&id=FA241103


         

        What is the aperture/opening size of the gland on the rear 56P315?

        The aperture/opening size of the gland on the rear 56P315 is - 12mm
        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=56P315
        User-added image

        What is part number for 3 Phase pendant outlet to suit 56P315?

        Part number 56POK is used with 3 phase 15amp plug.
         

        Is the 56C310 available with a key switch?

        No, unfortunately this is not a standard part. However it can be made out of parts.

        You would need:
        56K1SW1156LE or 56K2SW115LE
        56SO310LE
        56E2

        For further information please visit https://www.clipsal.com/Trade/search-results?q=56

        What is the part number for the switch used in a 56C710?

        The part number for the switch used in a 56C710 is 56SW410.

        Some of the key features are:
        • 10 A thermal current
        • 2 module Model
        • 7 Round pins
        • 3 pole
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C710


         

        What is the function of the interlock on 56CVI one peice models of 56 series switched socket outlet?

        Mechanical interlock is an optional feature to ensure power disconnection before insertion or removal of the plug. Internal interlock facility is available on three phase, one piece cover  switched socket outlets.  add I to Catalogue Number e.g. 56CV410 becomes 56CVI410.

        What is the maximum cable size for a 56P520?

        The maximum conductor size for a 56P520 is 4mm sq with a maximum cable diameter of 15.7mm

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P520
         

        Can the PDL 56SS10 Sunset Switch be used with LED's?

        Yes and No theycan handle some loads, 
        However a large number of LED flood light lamps do not manager the inrush current at all and this can cause damage to the electronic and weld the contacts closed.
        We recommend you use a relay ie 600RM for small loads Or better use one of the new Smart high proformance contactor (Zero crossing switching ) these are dsigned for switching LEDs loads. 
         

        Is there an IP66 rated 2 gang vertical outlet in 2000 range?

        No there is no IP66 rated outlet in the 2000 series. For IP66 outlets the 56 Series would be the best option
        For Clipsal 2000 series information click this link https://www.clipsal.com/Trade/search-results?q=2025v

        For Clipsal 56 Series please click this link https://www.clipsal.com/Trade/search-results?q=56c310

        Does the parts in a 56C310 fit into the old 56 series base?

        Yes, they fit and are interchangable. The only visable difference is a small change in appearence.

        For further information please visit https://www.clipsal.com/56series
         

        Is it possible to swap a 56C315 for a 56C310 on the same base?

        Yes, you can remove the 56C315 switch mechanism and socket outlet, and replace it with a 56C310LE, provided the power supply is 10 amp and not 15 amp it will be okay.

        Can I get a 56C310 with key lock switch?

        How to remotely trip a VIP410?

        Issue
        Cannot not remotely trip or close the breaker by using the VIP410

        Product Line
        VIP410

        Environment
        Closing or tripping a breaker remotely or through external input. 

        Cause
        Circuit Breaker Control is not on or the external wiring is not setup.

        Resolution
        There are two ways to remotely trip the VIP410 and Mitop Trip Unit
        1. Using communications for tripping through VIP410.
        2. External input trip, but usually this is for another protection device such as 'Buchholz' for example.

        Please see in extract of doc after.


        What is 56 Series equivalent to part number PDL MP410?

        The part number for 56 series equivalent is a 56P410.

        Is there a 56 series outlet to suit a 56P432 that restricts the plug from being removed when switched on?

        Yes, use of the 56CVI432 series will restrict removal while the outlet is switched on as there is an interlocking pin to hold the plug in place.
         
        Some of the key features are:
        • 32 A thermal current
        • Internal interlock switch
        • 4 round pins
        • 500V
        • IP66
        • 3 Pole
        • Vertical
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56CVI432 


         

        Do you do the socket outlet 56SO510 in the colour Woolworths Grey (WW)?

        If this particular item is needed you can purchase the 56C510 which is a combination Switch and socket outlet. This product comes in the colour Woolwoths Grey (WW).
        Some of the key features are:

        • 10 A thermal current
        • 5 Round pins
        • 3 pole
        • M100 Rating
        • 2 Piece with Wall Box
        For further informatiohn please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56C510

        What is the standard base depth that comes with the 56C310?

        The standard base depth that comes with the 56C310 is on a 38mm base.

        What is replacement for part no WICM110

        Part no WICM110 has been replaced with
        56C310 for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C310

        User-added image