Catalogue Number: 56E3

Mounting Back Box, 3 Gang

WPS_3G BACK BOX
3 gang industrial box
56E3WW 3 GANG INDUSTRIAL BOX PZ56 SERIES
WPS_3G BACK BOX
3 gang industrial box
56E3WW 3 GANG INDUSTRIAL BOX PZ56 SERIES
Colour: Grey
Colour: Per UOM Std.
  • Grey 1 PCE
  • Resistant Orange 1 PCE
  • Resistant White Electric 1 PCE
  • Woolworths Grey 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
  • 3 gang
  • 2 x 25 mm, 1 x 32 mm conduit entries
  • 2 x 25mm, 1 x 32mm rear cut-outs
  • Temperature range -25C to +75C
Range of product
Series 56
Range
Clipsal - 56 Series
Product brand
Clipsal
Product or component type
enclosure
Colour
grey (RAL 7035)
Number of gangs
3 gangs
Device mounting
surface
Mounting mode
wall-mounted
Cable entry number
3
Material
PVC (polyvinyl chloride): housing
Number of mounting holes
16
Cable entry
  • 1 cut-out diameter: 32-32 mm
  • 2 cut-out diameter: 25-25 mm
    • Length
      294 mm
      Width
      102 mm
      Depth
      63 mm
      Height
      294 mm
      Net weight
      0.547 kg
      IP degree of protection
      IP66 conforming to AS 60529
      Standards
      AS 3100
      Compatibility code
      56 Series covers
      Ambient air temperature for operation
      -25-75 °C
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      California proposition 65
      WARNING: This product can expose you to chemicals including: which is known to the State of California to cause Not determined harm. For more information go to www.p65warnings.ca.gov

      Documents & downloads

      hide show
      Filter items
      • All

      • CAD Files and Packs

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the part code for a PDL56DOL starter switch

      You can use a 56DOL + 56SW to suit application in a 56E3 box

      What is the part code for a 10A 1phase Socket protected by 10mA RCD

      You can use 56SO310 +56CB4 + 56E3 + 4RCBE210/10

      What is the difference between the 56E3 and the EY56E3?

      The EY56E3 is the older model and only available in Grey.

      They are fully compatible with the 56 series.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=EY56E3

      Can I still buy a 56 Series ELCB

      56 Series is deleted 2007. 
      But you can use RCBO - PDL 56CB4 + PDL 56E3 + PDL 56SO310

      What are the dimensions of the PDL 56E3 enclosure?

      Height 295mm, Depth 63mm and Width 102mm

      Please see the attached product catalogue for more information
       

      Can you have a 56E3 base with a switch and a 15 amp and a 10 amp socket on it?

      Yes, as long as it complies with AS3000 that should be okay. Consider circuit breaker and cable size.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=56%20seriers.

      What is the part number for 56 Series Dividers?

      The part number is 56DV-BK.

      Some of the key features are:
      • For segregated services in 56e enclosures
      • Black colour

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56DV

      What are the part numbers for a 56 series 4 pin 32amp outlet with RCD unit?

      The part numbers for a 56 series 4 pin 32amp outlet with RCD unit is - 56E3 , 56SO432LE & 56CB4N

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E3
      https://www.clipsal.com/Trade/search-results?q=56SO432LE
      https://www.clipsal.com/Trade/search-results?q=56CB4N
      User-added image
      User-added image
      User-added image

      What are the part numbers to make up a 56 series 3 flat pin 10amp outlet with RCD protection and LED indication?

      The part numbers to make up a 56 series 3 flat pin 10amp outlet with RCD protection and LED indication are - 56E3 , 56SO310LE & 56CB4N

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E3
      https://www.clipsal.com/Trade/search-results?q=56SO310LE
      https://www.clipsal.com/Trade/search-results?q=56CB4N
      User-added image
      User-added image

      User-added image

      What is the part number for a 56 series 3 gang base with RCD protection and 2 x 10amp socket outlets with round earth pin?

      The part numbers for a 56 series 3 gang base with RCD protection and 2 x 10amp socket outlets with round earth pin are - 56E3 , 56SO310ALLE  & 56RCLE

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56E3
      https://www.clipsal.com/Trade/search-results?q=56SO310ALLE
      https://www.clipsal.com/Trade/search-results?q=56RCLE
      User-added image
      User-added image
      User-added image