RCD Protected Switched Socket Outlet, 500V, 20A, 4 Round PIN, IP66, 30mA RCD

RCD Protected Switched Socket Outlet, 500V, 20A, 4 Round PIN, IP66, 30mA RCD

RCD Protected Switched Socket Outlet, 500V, 20A, 4 Round PIN, IP66, 30mA RCD

Item Number: 56C420RC-GY

Retail
$1,093.84
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE
  • Resistant Orange 1 PCE

Product Dimensions

Width icon

Width101 mm

Height icon

Height294 mm

Depth icon

Depth110 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Series 56

Range

Clipsal - 56 Series

Product brand

Clipsal

Product or component type

socket-outlet with residual current device

Device application

power supply

Market segment

  • industry
  • small commercial
  • utility
    • Sustainable offer status

      Green Premium product

      Physical

      Number of poles

      4

      Control type

      push-button

      Number of power socket outlets

      1 protective cover

      [In] rated current

      20 A

      [Ue] rated operational voltage

      500 V AC 50 Hz

      Number of gangs

      3 gangs

      Installation direction

      vertical

      Device mounting

      surface

      Connections - terminals

      screw terminals cable(s) 1.5-16 mm²

      Depth

      110 mm

      Width

      101 mm

      Height

      294 mm

      Net weight

      1.6 kg

      Ambient air temperature for operation

      -25-75 °C

      IP degree of protection

      IP66

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120809EN

      Material

      Material

      polycarbonate

      Others

      Network number of phases

      3 phases

      Targeted country

      Australia

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      1614 g

      Package 1 Height

      110 mm

      Package 1 width

      105 mm

      Package 1 Length

      305 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the difference between the 56SC520RC and the 56C520RC?

      The 56SC520RC has a Switch to operate the outlet where as the other one doesnt

      What is part number for RCD cover to suit 56C520RC?

      The part number for RCD cover to suit is a 56CB4N.

      Can the RCD in the 56C420RC, be wired without a Neutral?

      Yes it can be wired without a Neutral.

      What is the part number of the replacement RCD to suit 56SC420RC, 500V, 20A RCD protected switched outlet?

      4RC425/30 is the part number of the RCD supplied with 56SC420RC. 4RC425/30 is 4 pole rated to 415V, 25A, 30mA.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC425/30
       

      What is the part number of the replacement RCD to suit 56SC520RC?

      4RC425/30 can be used as a replacement RCD for 56SC520RC. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC425/30

      What is part no for 56 series Switched Socket outlet with RCD?

      Part no is 56SC520RC 5 pin 20amp Switched socket outlet

      Is there an IP56 rated, 4 pin 20amp switched outlet?

      Yes, the part name is 56C420-GY

      What is the RCD in the 56C510RC RCD protected combination outlet?

      The RCD in the 56C510RC RCD protected combination outlet is a 4RC463/30.
      Some of the key features are:
      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure
      • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
      • Same housing as AC type MCBs. Uniformity in space requirements and installation
      • Superior, safe and reliable DC breaking per pole
      • Used with marine, telecommunications, solar power, emergency power, battery power
      • Excellent breaking capability for its compact size
      • Standard type
      • 75 mm modular spacing
      • Surge current protected to 250 A at 8/20 uS
      • Operating temperature: -5 to 40 deg C
      • Degree of pollution is 2
      • Rated Impulse withstand voltage is 6 kV
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RC463/30

      What is the 56C310 with an RCD attached?

      Part No.: 56SC310RC

      Does the MSC432RTD and the 56SC432RC have the same pin configuration?

      Yes, they do have the same pin configuration.

      Can I swap the RCD out from a 56C315RC with a different RCD?

      You can but you have to change it from a 2 module to a 3 module and use the 56CB4-GY to fit a normal RCD in the top section.

      Can you purchase the RCD on its own for the 56C310RC?

      Yes, the part number is 56RC.
      Some of the key features are:
      • Conductor terminal size: 16 to 10 AWG
      • 1 phase
      • 2 pole
      • 20A
      • IP66
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56RC
      Show More