Quantcast

500 Series Cable Connectors, 2 Screw, Hexagonal, Suits up to 3 x 6mm² Cables

500 Series Cable Connectors, 2 Screw, Hexagonal, Suits up to 3 x 6mm² Cables

500 Series Cable Connectors, 2 Screw, Hexagonal, Suits up to 3 x 6mm² Cables

Item Number: 562A

Retail
$3.52
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Provided equipment

2 x screw

Connector type

screw terminals

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP121019EN

Others

Cable cross section

6-6 mm² fine stranded without cable end sleeve

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

8 g

Package 1 Height

14 mm

Package 1 width

11 mm

Package 1 Length

15 mm
Show all specifications

Frequently Asked Questions

hide show

What is the suspension hook for the PDL 56 Series

You can use PDL56SHL - Suspension Hook (large) this is to fit the 56P and 56PA plugs and/or 56CR socket connectors.  

What is the part number of the flush surround to suit 56CV, one piece cover, switched outlets?

56FA2 is the part number of the flush surround to suit 56CV, one piece cover switched outlets. Surface mounted 56 Series Sockets, Switches and Combinations can be transformed into flush mounting equivalents using the 56FA Surrounds and Brackets. The surrounds can be used on various types of walls to ensure a neat installation, such as:
• a mounting enclosure (back box) in poured concrete
• a bracket on brick, brick veneer or panel walls.
The brackets provide the installer with a  practical method of flush mounting 56 Series accessories. Comprehensive installation instructions are supplied with all units.
56FA1, 56FA2, 56FA3 and 56FA4 Flush Surrounds contain a moulded flange, foam gasket and stainless steel mounting screws.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2

What is the cut-out for the 56FA flush mount surround?

Solid and Cavity Brick Walls (Bracket Mounting)

Prepare wall by cutting hole 90 x 90mm for 56FA1, 90 x 190mm
for 56FA2, 90 x 285mm for 56FA3 and 190mm2 for 56FA4.
Mount bracket to exterior wall using any suitable fixing device i.e.
thrubolts, fibre plugs, etc.
Remove adhesive backing sheet from gasket and adhere to inner
surface of flange. Mount modules to bracket through flange.
Note: 1. For soft or porous brickwork we suggest adhesive
anchored fixing.
2. When mounting to brick ensure all mortar joints are
sealed with suitable caulking compound.

 

Panel Type Walls (Bracket Mounting)

Prepare wall by cutting hole as described above for solid and
cavity brick walls. Mount bracket to wall using suitable hollow wall
anchors. Adhere gasket to flange and mount modules through
flange to bracket.
Note: If possible mount bracket to building frame i.e. wooden
noggins and studs with suitable wood screws.

Video: Changing the settings with the LCD screen on an H, J, or L frame circuit breaker

Issue:
How do I change the settings with the LCD screen on an H, J, or L frame circuit breaker?
 
Product Line:
Micrologic Trip Units
 
Environment:
H, J, and L-frame Circuit Breakers
 
Cause:
How do I change the settings with the LCD screen on an H, J, or L frame circuit breaker?
 
Resolution:
 
Access the values by first unlocking the trip unit, then using the menu button until you reach the trip unit values. You can then select which setting you want to change using the right arrow (or scroll) button, and use the up and down arrows to reach the desired setting. You then must hit the OK button twice to save the setting. See instructional video below for additional help in changing the settings:

 

What are the secondary injection test kits for Micrologic circuit breakers?


Product Line:
Legacy, Powerpact, and Masterpact circuit breakers

Resolution:
The secondary injection test kit for Legacy Micrologic (Micrologic Series B) breakers is the UTS3.
The Full Function Test Kit  (FFTK) for Powerpact M, P, R frame and Masterpact circuit breakers with electronic or Micrologic trip units is S33595.
The Hand Held Test Kit (HHTK) for Powerpact M, P, R frame and Masterpact circuit breakers with electronic or Micrologic trip units is S33594.
The UTA tester for testing Powerpact H, J, Lcircuit breakers is STRV00910.
The Pocket Tester for testing Powerpact H, J, Lcircuit breakers is S434206.
The Universal Test Kit for testing Legacy Micrologic (Micrologic Series B) trip units is UTS3.
The test kit for testing Masterpact and Compact circuit breakers with STR trip units is 55391.
 

What is the replacement model for a NS100N 3 Pole molded case circuit breaker?

The replacement model for a NS100N 3 Pole is the NSX100F 3P range.

NSX100F: (36kA at 415V)
Complete/3 Pole Front Connected
DescriptionTypeTrip UnitRatingPart Number
NSX100F (36kA) Distribution ProtectionStandard thermal-magnetic trip unit TM-DTM16D11-16ALV429637
TM25D17-25ALV429636
TM32D22-32ALV429635
TM40D28-40ALV429634
TM50D35-50ALV429633
TM63D44-63ALV429632
TM80D56-80ALV429631
TM100D70-100ALV429630
Electronic Trip unit Micrologic 2.2 (LSol)40A18-40ALV429772
100A40-100LV429770
Electronic Trip unit Micrologic 5.2A (LSI) (ammeter)40A18-40ALV429882
100A40-100LV429880
NSX100F (36kA)
Motor Protection
Nagnetic only trip Unit MAMA2.52.5A, 0.75kWLV429745
MA6.36.3A, 2.2kWLV429744
MA12.512.5A, 5.5kWLV429743
MA2525A, 11kWLV429742
MA5050A, 22kWLV429741
MA100100A, 45kWLV429740
Electronic Trip unit Micrologic 2.2 (LSol)25A12-25A, 11kWLV429828
50A25-50A, 22kWLV429827
100A50- 100A, 45kWLV429825



There is also a 4P model as well.

Please see link to Product guide - https://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/297000/FA297893/pl_PL/CROSSFER%20NS%20TO%20NSX.pdf