Computer Surface Modules - IP66, Computer accessory to Suit DB25 Connector

Grey | Computer Surface Modules - IP66, Computer accessory to Suit DB25 Connector

Computer Surface Modules - IP66, Computer accessory to Suit DB25 Connector

Item Number: 56/01/1-GY

Retail
N/A
RRP (Inc. GST)
Colour Grey (GY)
  • Grey 1 PCE

Product Dimensions

Width icon

Width107 mm

Height icon

Height107 mm

Depth icon

Depth77 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Series 56

Range

Clipsal - 56 Series

Product or component type

socket-outlet

Device application

power supply

Product brand

Clipsal

Market segment

  • utility
  • industry
  • small commercial
    • Sustainable offer status

      Green Premium product

      Physical

      Quantity per set

      set of 1

      Outlet standard

      industrial

      Marking

      without marking

      Local signalling

      without light indicator

      Device mounting

      surface

      Fixing mode

      by screws

      Depth

      77 mm

      Width

      107 mm

      Height

      107 mm

      Net weight

      0.001 kg

      Ambient air temperature for operation

      -25-75 °C

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Environmental Disclosure

      ENVPEP120809EN

      Material

      Material

      polycarbonate: cover

      Others

      Plug, socket category

      low voltage

      Cover type

      full cover plate

      Tightening torque

      0.8 N.m

      Targeted country

      Australia

      Package 1 Weight

      0.001 kg
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Product Environmental

      • Specifications

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Can I mount a 30 series intermediate switch in a 56/01X?

      The 56/01X is for mounting of a DB25 socket and not a 30 series mechanism.

      To mount a switch you would use a 56/32.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56/32

      What is the replacement push buttons for the 56PB1/G

      There is no replacement push button available

      What is the part number for the KRIX Holographix speakers , and are they still available?

      The part number is 5600K01 , and they have been discontinued
       

      What is the number of funtions or units per type of protection for Sepam 1000+?


      NOTE: Use the SFT2841, phase protection 50/51-1 tab for a better understanding of what follows.

      DEFINITION: the number of functions is referred to as the number of units.


      Series 20


      Characteristics of 50/51 phase overcurrent protection units:

      - the 50/51 function includes 2 units, identified as 50/51-1, 50/51-2

      - the units are identical

      - each unit can control a different output

      - each unit has 2 groups of settings, called set A and set B

      - this makes it possible to have 2 different groups of settings per unit

      (curve, threshold, delay and other parameters)

      - the setting groups may be active separately or together or according to

      certain criteria (set up in SFT2841)

      - only one output per unit, common to both groups of settings A and B

      - each unit has its own protection setting,

      - the units are dependent on the common general parameter setting "choice of

      setting group A/B".



      Series 40


      Characteristics of 50/51 phase overcurrent protection units:

      - the 50/51 protection function includes 4 units, identified as 1 to 4

      - the units are identical

      - each unit can control a different output

      - the 4 units are grouped in 2 setting ranges, group A and group B

      this makes it possible to have a total of 8 different groups of settings

      (curve, threshold, delay)

      - the setting groups A and B only operate as exclusive OR, i.e. 1 setting

      group active at a time

      - each unit has its own protection setting



      Summary


      For the 50/51 protection function:

      - Sepam series 20 offers:

      2 units with 2 groups of settings each (A and B)

      i.e. a total of 4 groups of settings that can operate separately or at the

      same time and that activate 2 outputs

      - Sepam series 40 offers:

      4 units with 2 groups of settings (A and B)

      i.e. a total of 8 groups of settings that activate 4 outputs

      Re-published to revised security level: 17 June 2008 by DRM

      Applies To: Sepam 1000+ (Sepam Series 20 and Sepam Series 40)

      Public

      All content © 1992-2008 Schneider Electric


      Legacy KB System (APS) Data: RESL166615 V2.0, Originally authored by LaVI on 06/20/2008, Last Edited by DaMi on 06/20/2008
      Related ranges: Sepam series 20, Sepam series 40