Wiser for C-Bus Automation Controller

C-Bus Wiser Automation Controller, RS232/485, Ethernet, Din Mount, 24V DC

Catalogue Number: 5500SHAC
Wiser for C-Bus Automation Controller
Retail
$1871.87*
RRP (Inc. GST)

Specifications

hide show
Range
Wiser
Product name
C-Bus Automation Controller
Product or component type
logic controller
Communication port protocol
  • C-Bus RJ45 (2000 devices)
  • IP (Internet Protocol) RJ45
  • serial link terminal block RS232
  • BACnet IP RJ45 (50 devices)
  • Modbus RTU terminal block RS485 (6 devices)
  • Modbus TCP RJ45
    • [Us] rated supply voltage
      24 V DC
      Power consumption in W
      2 W
      Local signalling
    • LED (green/red)power:
    • LED (green/red)status indication:
    • LED (green)relay output (REL):
    • LED (multi-colour)input status:
    • LED (multi-colour)RS232 link activity:
    • LED (multi-colour)serial link communication (RS485, RX, TX):
    • LED (green)C-Bus status:
    • LED (green/yellow)Ethernet link:
      • Port Ethernet
        10BASE-T/100BASE-TX
        Number of port
      • 1 USB 2.0 type A
      • 1 USB 1.1 type B
      • 1 RS232 (serial link)
      • 1 RS485 (Modbus)
      • 2 RJ45 (C-Bus)
      • 1 RJ45 (Ethernet)
        • Control type
        • smartphone or tablet
        • remote control
        • RESET push-button
        • local control
        • by touch panel
        • by web browser
        • RESET push-button cold restart
          • Web services
            web server
            Function available
          • visualisation
          • updateable software
            • Number of inputs
              1-1 dry contact
              Input impedance
            • 2.2 kOhm closed
            • 6.9 kOhm opened
              • Number of outputs
                1 relay changeover
                Output voltage
              • 24 V DC 1 A for relay
              • 48 V AC 1 A for relay
                • Connections - terminals
                • power supply: screw terminal 3 cable(s) 1.5-1.5 mm²
                • LED lamp: screw terminal 2 cable(s) 1.5-1.5 mm²
                • relay digital output: screw terminal 3 cable(s) 1.5-1.5 mm²
                • digital input: screw terminal 2 cable(s) 1.5-1.5 mm²
                • RS232 link: screw terminal 3 cable(s) 1.5-1.5 mm²
                • RS485 link: screw terminal 5 cable(s) 1.5-1.5 mm²
                  • Mounting support
                    DIN rail
                    Total number of 18 mm modules
                    6
                    Height
                    108 mm
                    Width
                    93 mm
                    Depth
                    63 mm
                    Market segment
                    residential
                    Ambient air temperature for operation
                    -5-45 °C
                    Operating altitude
                    <= 2000 m
                    Relative humidity
                    10-90 %
                    IP degree of protection
                    IP20
                    Directives
                  • 2011/65/EU - RoHS directive
                  • 1907/2006/EC - REACH directive
                  • 2002/96/EC - WEEE directive
                    • Standards
                    • EN 55022 class A
                    • AS/NZS CISPR 22
                      • EU RoHS Directive
                        Compliant
                        Mercury free
                        Yes
                        RoHS exemption information
                        Yes
                        China RoHS Regulation
                        Product out of China RoHS scope. Substance declaration for your information
                        Environmental Disclosure
                        ENVPEP1701009EN
                        Circularity Profile
                        ENVEOLI1701009EN

                        Documents & downloads

                        hide show
                        Filter items
                        • All

                        • Product Brochures

                        • CAD Files and Packs

                        • Technical Leaflet

                        • Product Environmental

                        • End of Life Manual

                        • Operating Manuals

                        • System User Guide

                        • Specifications

                        • Application Solutions

                        • Certificates (MSDS)

                        • Corporate Marketing

                        • Software - Released

                        Frequently Asked Questions

                        hide show

                        What is used as the C-Bus to Bacnet Gateway

                        The 5500NAC or 5500SHAC can be used as Bacnet gateway depending on the number of Bacnet points which are required.
                        The 5500NAC has 500 Bacnet Points and the 5500SHAC has 50 Bacnet points.
                        Bacnet is normally used by Building Management systems.

                        Does 5500SHAC Wiser for C-Bus Automation Controller come with a power supply?

                        5500SHAC does not come with a power supply. 
                        24Vdc, 10W Max, 2W typical plug-pack or similar needs to be purchased separately. 
                        For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001832.pdf

                         

                        Where to set Port numbers using NAC or SHAC

                        Access “Configuration” window on the web browser, select “System”, select “Services” which will allow you access to “HTTP server settings”, this is where your ports can be set.

                        How to import a background picture into the 5500SHAC

                        Issue: Importing a background image into the 5500SHAC is not a straightforward process.

                        Product Line:
                        C-Bus Automation controllers

                        Environment:
                        Internet Explorer, Mozilla Firefox, Google Chrome

                        Solution:
                        Will be filled in once I actually know the process myself

                        :CBUS: Can you operate the 5500shac network directly from the 5000EPT10W touchscreen?

                        Yes, using either crossover or straight through network cable

                        Touchsrcreen need to be on the same IP range as the Shac/Nac
                         

                         

                        How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC (5500SHAC)?

                        A Configuration Guide exist on the Exchange Community, see the link below or the attachment.

                        How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC



                         

                        ​Is there an alternative C-Bus Colour Touch Screen for BS5000CTC2?

                        This model of touchscreen has reached end of life. It has been replaced by the new Small Home Automation Controller (5500SHAC). This needs to be coupled with a display, of which our offer is the 5000ETP10W.

                        Are the TMC2 input and output cartridge modules for Modicon M221 PLCs electrically isolated?

                        Issue
                        Are the TMC2 input and output cartridge modules for Modicon M221 PLCs electrically isolated?

                        Product Line
                        Modicon M221 PLCs

                        Catridge modules:
                        TMC2AI2
                        TMC2AQ2C
                        TMC2AQ2V
                        TMC2CONV01
                        TMC2HOIS01
                        TMC2PACK01
                        TMC2SL1
                        TMC2TI2

                        Environment
                        Analog I/O Modules

                        Resolution
                        The TMC2 analog input and output cartridge modules are not electrically isolated between the input/output and the internal logic or supply voltage.
                        For electrically isolated analog input and output modules (500VAC between input and internal logic, 1500VAC between input/output and supply), please use the TM3 Analog I/O Modules.

                        What is the part number of C-Bus pascal automation controller?

                        5500PACA is the part number of C-Bus pascal automation controller.
                         

                        Key Features

                        • Provides extended conditional and real time event programming for C-Bus
                        • 4M DIN modules wide
                        • 2 x RS-232 ports for third party device control
                        • A scheduling tool allows time-based events to be programmed into the unit
                        • A scene programming tool allows installers to quickly and easily program scenes into the unit
                        • A programming wizard provides a GUI based method for creating basic logic programs
                        • More complex programs are produced by advanced users utilising the free-form text programming method
                        • Programming language based on the standard Pascal computer language, enhanced by Clipsal with specific commands related to C-Bus control
                        • The language supports commands such as: Conditional logic (if, then, and, or, not, etc.), Flow control (for, repeat, while), Variables (integer, real, Boolean, character, string), Control and monitor C-Bus group addresses, Control and monitor C-Bus scenes, C-Bus tag names
                        • Serial (RS-232) input/output

                        For further information, please visit  https://www.clipsal.com/Trade/Products/ProductDetail?catno=5500PACA