Clipsal C-Bus Network Automation Controller, SpaceLogic C-Bus 6DIN

Clipsal C-Bus Network Automation Controller, SpaceLogic C-Bus 6DIN

Item Number: 5500NAC2

Datasheet

Product Dimensions

Width icon

Width93 mm

Height icon

Height108 mm

Depth icon

Depth63 mm

Specifications

Design

Range

SpaceLogic C-Bus

Product or component type

logic controller

Market segment

  • buildings
  • residential

Sustainable offer status

Green Premium product

Physical

Communication port protocol

  • C-Bus RJ45 (4000 devices)
  • BACnet IP RJ45 (2000 devices)
  • Modbus RTU terminal block RS485 (31 devices)
  • IP (Internet Protocol) RJ45
  • serial link terminal block RS232
  • Modbus TCP RJ45

Power consumption in W

2 W

Local signalling

  • LED (green/red) for power
  • LED (green/red) for status indication
  • LED (green) for relay output (REL)
  • LED (multi-colour) for input status
  • LED (multi-colour) for RS232 link activity
  • LED (multi-colour) for serial link communication (RS485, RX, TX)
  • LED (green) for C-Bus status
  • LED (green/yellow) for Ethernet link

Control type

  • smartphone or tablet
  • RESET push-button cold restart
  • by web browser
  • by touch panel
  • remote control
  • local control
  • RESET push-button

Function available

  • updateable software
  • visualisation

Connections - terminals

  • power supply: screw terminal 3 cable(s) 1.5-1.5 mm²
  • LED lamp: screw terminal 2 cable(s) 1.5-1.5 mm²
  • relay digital output: screw terminal 3 cable(s) 1.5-1.5 mm²
  • digital input: screw terminal 2 cable(s) 1.5-1.5 mm²
  • RS232 link: screw terminal 3 cable(s) 1.5-1.5 mm²
  • RS485 link: screw terminal 5 cable(s) 1.5-1.5 mm²

Mounting support

DIN rail

Height

108 mm

Width

93 mm

Depth

63 mm

Ambient air temperature for operation

-5...45 °C

Relative humidity

10...90 %

IP degree of protection

IP20

Standards

  • EN 55032: class A
  • EN 50491-5-2: class B
  • EN 55035

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

X

Environmental Disclosure

ENVPEP2104025EN

Circularity Profile

ENVEOLI2104025EN

Others

Package 1 Bare Product Quantity

1

Product name

C-Bus Automation Controller

[Us] rated supply voltage

24 V DC

Port Ethernet

10BASE-T/100BASE-TX

Number of port

  • 1 USB 2.0 type A
  • 1 USB 1.1 type B
  • 1 RS232 (serial link)
  • 1 RS485 (Modbus)
  • 2 RJ45 (C-Bus)
  • 1 RJ45 (Ethernet)

Web services

web server

Web server

BMS controller compatible

Number of inputs

1 dry contact

Input impedance

  • 2.2 kOhm closed
  • 6.9 kOhm opened

Number of outputs

1 relay changeover

Output voltage

  • 24 V DC 1 A for relay
  • 48 V AC 1 A for relay

Total number of 18 mm modules

6

Operating altitude

<= 2000="">

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.3 cm

Package 1 Width

6.3 cm

Package 1 Length

10.8 cm

Package 1 Weight

364.0 g

Unit Type of Package 2

CAR

Number of Units in Package 2

10

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

4330.0 g

Unit Type of Package 3

P12

Number of Units in Package 3

240

Package 3 Height

95.0 cm

Package 3 Width

80.0 cm

Package 3 Length

120.0 cm

Package 3 Weight

108.0 kg
Show all specifications

Frequently Asked Questions

hide show

What is the latest firmware version for C-Bus 5500NAC, 550SHAC, 5500NAC2 and 5500AC2 Automation Controller?

What is the latest firmware version for C-Bus 5500NAC, 550SHAC, 5500NAC2 and 5500AC2 Automation Controller?

Their latest firmware version is 1.12.0 and released on 24/10/2022, they can be download from SE and SEecoxpert website.

C-Bus Firmware for 5500NAC2 Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500NAC2_Firmware-V1.12.0/

C-Bus Firmware for 5500AC2 Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500AC2_Firmware-V1.12.0/

C-Bus Firmware for 5500NAC Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500NAC_Firmware-V1.12.0/

C-Bus Firmware for 5500SHAC Automation Controller V1.12.0
https://www.se.com/ww/en/download/document/5500SHAC_Firmware-V1.12.0/

 

How to download the firmware files from se.com (global page)?

First, you need to find the product page! I.e 5500NAC2

 

  1. Type in the commercial reference in the search bar, and once the product you are looking for pop-up, click on the product bar.

 5500NAC2 1

 

  1. Once on the product page, scroll down, pass Main Documents > Specifications > Documents, and reach the Software and Firmware section at the bottom.

 5500NAC2 2

 

  1. Select “Firmware” for the latest version in the Document type section, or if you are looking for previous firmware files, you can see them under “Firmware – History and others”.

 5500NAC2 3

  1. You can download the firmware, release notes, and user manual separately OR as a whole in zip format.

How to configure BACnet on 5500NAC/SHAC ?

 

Please see attached link to the manual. Attention to page (142-144)

https://updates.clipsal.com/ClipsalSoftwareDownload/mainsite/cis/technical/AutoController/5500NAC_5500SHAC_FW_v1.0_EN.pdf

 Automation Controller can act as a BACnet server only (not as a client)

1

2

3

4

5

6

7


 

How to config SE8350 or SE8650 for Modbus RS-485 communications to SpaceLogic C-Bus Automation Controllers

1) Enter the Setup screen
Enter the Setup screen
Note: password reset is not within the scope of this FAQ. If you are a Certified EcoStruxure Building Operations (BMS) Partner and require the password to be reset. Please contact Schneider Electric Technical Support for further assistance 

2) Select the Network option 
Select network settings

3) Select the Wire protocol option
Select Modbus option

4) Enter the Modbus settings 

Enter Modbus settings

5) Enter the Modbus COM address

Enter Modbus COM address

6) Select the Modbus Network units

Select Network units

7) Select the Modbus Baud rate

Setting Modbus Baud rate
NOTE: It is recommended to choose either 9600 or 19200 (default) baud rate as most Modbus devices are compatible with either of these two rates. 

8) Select the Modbus Parity

Setting Parity bit

9) Select the Return to Setup Screen (twice)

How to configure a C-Bus Automation Controller to SE8350 or SE8650 Room Controller for Modbus RS-485 communications

Upon successful login to the C-Bus 5500NAC2 (Network Automation Controller) or 5500AC2 (Application Controller)

Setting Modbus RTU Settings
1) Select the Configurator option from the 5500NAC2 / 5500AC2 - start page 
2) Select the Modbus tab to display modbus devices, settings and options
3) Select the RTU Settings option in the bottom left corner
4) Check the RTU (serial) enabled option for an available RTU connection 
5) Set the port to /dev/RS485 
6) Set the baud rate to match baud rate set in SE8350 or SE8650 (possible options - 4800, 9600, 19200, 38400, 57600)
7) Set the parity bit to match parity set in SE8350 or SE8650 (possible options none (1 stop bit), odd, even, none (2 stop bit). 
8) Set duplex option to "half duplex"
9) Select the Save button to set the Modbus RTU Settings

example: 
RTU Settings Dialog

Scanning Modbus RTU for Devices
1) Select the RTU Scan option in the bottom left corner
2) Enter the Scan range start (COM address of first SE8350/8650 in daisy chain) 
3) Enter the Scan range end (COM address of last SE8360/8650 in daisy chain) 
4) Select the Save button to start RTU scan for modbus devices

example:
 
RTU Scan Dialog

5) From the RTU Scan results - check the add device option and specify the name, modbus profile (SE8300, SE8600 or SER8300 depending on series of SE Room Controller). 
Note: The SE8300 series profile covers the SE8350 room controllers, SE8600 series profile covers the SE8650 room controllers. 

example:
RTU Scan Result Dialog

6) Select the Save button to add the devices to the list of modbus devices

Adding User Parameter Objects - Needed for Modbus Mapping
1) Select the Objects tab from the configuration page tabs to display C-Bus Automation Controller objects
2) Select the Add New Object option in the bottom left corner to add a user parameter which will later be mapped to a modbus device register
3) Select User Parameter option from the Application dropdown
4) Add a new variable address and provide a meaningful tag name
5) Select an option that matches the modbus register type from the Data type dropdown (eg floating point for temperature reading or temperature setpoint)
6) Specify keywords, units, comments as appropriate
7) Select the Save button to add the new user parameter to the list of C-Bus Automation Controller objects

example: 
 
Add Object Dialog

example: the newly added user parameter object will appear in the objects list and its value prior to modbus mapping will be shown as the default value in this case 0.000°C

User Parameter Object

Mapping Modbus Device Registry to User Parameter
1) Select the Modbus tab from the configuration page tabs
2) From the modbus device list select the applicable modbus device's mapping icon under the mapping column
3) From the modbus device's register list select the link to object field next to the modbus register to be mapped
4) From the mapping dialog use the link to object dropdown list to link the modbus register to the corresponding user parameter
5) Specify the value delta, units, keywords and comments as applicable
6) Select Save button to link the modbus device register to the user parameter object

example: 
 
Modbus Mapping Dialog

Check User Parameter value for updates from SE8350/8650 Room Controller
1) Select the Objects tab from the configuration page tabs to display C-Bus Automation Controller objects
2) Check that the User Parameter object which was just mapped from SE8350/8650 modbus device register is updating as expected

example: we can see the Room Temp user parameter is being updated from the Room Controller One - Room Temperature modbus registry

Mapped User Parameter Object
 
 

How to wire a C-Bus Automation Controller to SE8350 or SE8650 Room Controller for Modbus RS-485 communications

C-Bus Automation Controller Power Supply - Requirements
24V DC (+/- 5%), 10W max, 2W typical

SE8350/SE8650 Power Supply - Requirements
24V AC (+/- 15%), 50/60Hz, 6VA (0.25A)

Modbus RS-486 Cabling - Requirements
D1+ and D0- = Twisted Pair, Shielded, Imp 120Ω - eg Belden 9842
COM = Common (Reference) Wire

The 5500NAC2 and 5500AC2 contain the following optional in-built terminators options:
low power terminator of 120 Ω + 1 nF via link AT–BT
legacy terminator of 120 Ω via link BT-A

5500NAC2 or 5500AC2 - D1+ connector is wired to pin 13 (RS-485 +) on the SE8350/8650               - shown by brown wire
5500NAC2 or 5500AC2 - D0- connector is wired to pin 14 (RS-485 -) on the SE8350/8650                 - shown by blue wire
5500NAC2 or 5500AC2 - COMM - connector is wired to pin 15 (RS-485 REF) on the SE8350/8650     - shown by green wire

Modbus RS-485 communication line must be terminated at each end
C-Bus Automation Controller  to SE Room Controller Modbus Wiring

Refer to the 5500NAC2 or 5500AC2 Quick Start Guide and User Manual for further details regarding the C-Bus Automation Controller Power Supply and Modbus RS485 Modbus wiring connectors and wiring/electrical requirements. These can be found by scrolling to the bottom of the product page and downloading the applicable pdf
https://www.se.com/ww/en/product/5500AC2/application-controller-spacelogic-cbus-rs232-485-ethernet-din-mount-24v-dc/
https://www.se.com/ww/en/product/5500NAC2/network-automation-controller-spacelogic-cbus-bacnet-modbus-ip-6m-din-mount-24v-dc/

Refer to the SE8350 or SE8650 Installation Guide for further details on the wiring connectors
https://www.se.com/au/en/download/document/II-SE8300/
https://www.se.com/au/en/download/document/II-SE8600/
Show More