Network Automation Controller

C-Bus Network Automation Controller, BACnet, Modbus, IP, 6M, Din Mount, 24V DC

Catalogue Number: 5500NAC
Network Automation Controller
Retail
$2,768.48
RRP (Inc. GST)

Specifications

hide show
Range
C-Bus
Product name
C-Bus Automation Controller
Product or component type
logic controller
Communication port protocol
  • C-Bus RJ45 (2000 devices)
  • BACnet IP RJ45 (500 devices)
  • Modbus RTU terminal block RS485 (31 devices)
  • IP (Internet Protocol) RJ45
  • serial link terminal block RS232
  • Modbus TCP RJ45
    • [Us] rated supply voltage
      24 V DC
      Power consumption in W
      2 W
      Local signalling
    • LED (green/red)power:
    • LED (green/red)status indication:
    • LED (green)relay output (REL):
    • LED (multi-colour)input status:
    • LED (multi-colour)RS232 link activity:
    • LED (multi-colour)serial link communication (RS485, RX, TX):
    • LED (green)C-Bus status:
    • LED (green/yellow)Ethernet link:
      • Port Ethernet
        10BASE-T/100BASE-TX
        Number of port
      • 1 USB 2.0 type A
      • 1 USB 1.1 type B
      • 1 RS232 (serial link)
      • 1 RS485 (Modbus)
      • 2 RJ45 (C-Bus)
      • 1 RJ45 (Ethernet)
        • Control type
        • remote control
        • smartphone or tablet
        • RESET push-button
        • by touch panel
        • by web browser
        • RESET push-button cold restart
        • local control
          • Web services
            web server
            Web server
            BMS controller compatible
            Function available
          • visualisation
          • updateable software
            • Number of inputs
              1-1 dry contact
              Input impedance
            • 2.2 kOhm closed
            • 6.9 kOhm opened
              • Number of outputs
                1 relay changeover
                Output voltage
              • 24 V DC 1 A for relay
              • 48 V AC 1 A for relay
                • Connections - terminals
                • power supply: screw terminal 3 cable(s) 1.5-1.5 mm²
                • LED lamp: screw terminal 2 cable(s) 1.5-1.5 mm²
                • relay digital output: screw terminal 3 cable(s) 1.5-1.5 mm²
                • digital input: screw terminal 2 cable(s) 1.5-1.5 mm²
                • RS232 link: screw terminal 3 cable(s) 1.5-1.5 mm²
                • RS485 link: screw terminal 5 cable(s) 1.5-1.5 mm²
                  • Mounting support
                    DIN rail
                    Total number of 18 mm modules
                    6
                    Height
                    108 mm
                    Width
                    93 mm
                    Depth
                    63 mm
                    Market segment
                    buildings
                    Ambient air temperature for operation
                    -5-45 °C
                    Operating altitude
                    <= 2000 m
                    Relative humidity
                    10-90 %
                    IP degree of protection
                    IP20
                    Directives
                  • 2011/65/EU - RoHS directive
                  • 2002/96/EC - WEEE directive
                  • 1907/2006/EC - REACH directive
                    • Standards
                    • AS/NZS CISPR 22
                    • EN 55022 class A
                      • EU RoHS Directive
                        Compliant
                        Mercury free
                        Yes
                        RoHS exemption information
                        Yes
                        China RoHS Regulation
                        Product out of China RoHS scope. Substance declaration for your information
                        Environmental Disclosure
                        ENVPEP1701009EN
                        Circularity Profile
                        ENVEOLI1701009EN

                        Documents & downloads

                        hide show
                        Filter items
                        • All

                        • Product Brochures

                        • CAD Files and Packs

                        • Technical Leaflet

                        • Product Environmental

                        • End of Life Manual

                        • Operating Manuals

                        • System User Guide

                        • Specifications

                        • Application Solutions

                        • Certificates (MSDS)

                        • Corporate Marketing

                        • Software - Released

                        Frequently Asked Questions

                        hide show

                        What is used as the C-Bus to Bacnet Gateway

                        The 5500NAC or 5500SHAC can be used as Bacnet gateway depending on the number of Bacnet points which are required.
                        The 5500NAC has 500 Bacnet Points and the 5500SHAC has 50 Bacnet points.
                        Bacnet is normally used by Building Management systems.

                        Where to set Port numbers using NAC or SHAC

                        Access “Configuration” window on the web browser, select “System”, select “Services” which will allow you access to “HTTP server settings”, this is where your ports can be set.

                        How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC (5500SHAC)?

                        A Configuration Guide exist on the Exchange Community, see the link below or the attachment.

                        How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC



                         

                        What is the replacement for a 5500CN?

                        The replacement for a 5500CN is 5500CN2.

                        Does 5500SHAC Wiser for C-Bus Automation Controller come with a power supply?

                        5500SHAC does not come with a power supply. 
                        24Vdc, 10W Max, 2W typical plug-pack or similar needs to be purchased separately. 
                        For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001832.pdf

                         

                        What is the CBUS PC interface

                         The part code is 5500PC

                        Are the TMC2 input and output cartridge modules for Modicon M221 PLCs electrically isolated?

                        Issue
                        Are the TMC2 input and output cartridge modules for Modicon M221 PLCs electrically isolated?

                        Product Line
                        Modicon M221 PLCs

                        Catridge modules:
                        TMC2AI2
                        TMC2AQ2C
                        TMC2AQ2V
                        TMC2CONV01
                        TMC2HOIS01
                        TMC2PACK01
                        TMC2SL1
                        TMC2TI2

                        Environment
                        Analog I/O Modules

                        Resolution
                        The TMC2 analog input and output cartridge modules are not electrically isolated between the input/output and the internal logic or supply voltage.
                        For electrically isolated analog input and output modules (500VAC between input and internal logic, 1500VAC between input/output and supply), please use the TM3 Analog I/O Modules.

                        How to import a background picture into the 5500SHAC

                        Issue: Importing a background image into the 5500SHAC is not a straightforward process.

                        Product Line:
                        C-Bus Automation controllers

                        Environment:
                        Internet Explorer, Mozilla Firefox, Google Chrome

                        Solution:
                        Will be filled in once I actually know the process myself

                        :CBUS: Can you operate the 5500shac network directly from the 5000EPT10W touchscreen?

                        Yes, using either crossover or straight through network cable

                        Touchsrcreen need to be on the same IP range as the Shac/Nac
                         

                         

                        What is the current rating of the 93-WE ?

                        The Current rating is 16A, 500VAC

                        What power supply do i need to power my 5500PC PC interface?

                        You will need the 5500PS which is specifically designed to power a C-Bus network.

                        What is the part number of the power pack to suit 5500CN2?

                        Power pack is supplied with the 5500CN2. We do not sell a replacement power pack to suit 5500CN2. If a replacement power pack is needed we recommend a power supply which can provide between 6-12V DC 100mA.

                        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=5500CN2



                         
                        Show More