538-WH

Mounting Plate 2 Gang Conversion

Catalogue Number: 538
538-WH
Colour: White
Colour: Per UOM Std.
  • Black 1 PCE
  • White 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
  • 500 Standard Series
  • PDL
    • Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the 600 series adaptor to convert a 149 to 1 gang

       It is a PDL 538

      What is the code for a 2-gang conversion plate for PDL 500/600 series?

      Part code is PDL 538

      Does the PDL534P16 come with the PDL533 600 series mounting clips?

      Yes all three of the 534 multigang plates come with the 533 panel mounting clips.

      Do you have a 32A version of a 438 extension socket?

      No, the largest rated version of a 438 extension socket is the 438/20 which is 20A.

      How many types of keys are there for the PDL 568

      There is 200 different types of keys for the PDL 568

      Is the PDL 568 available in black?

      No, the PDL 568 only comes in white.

      What is the part code for Adjustable Batton Holders

      The clipsal code is 535

      What are the dimensions of the 535 power tower

       Dimensions 158 x 158 x 140mm high

      What are the dimensions of the 533 batten holder?

      The 533 batten holder has a base diameter of 90mm, overall lenght of 60mm and mounting centres of 50mm.

      For further informatiom please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=533

       

      Is part 530 available in Brown?

      No. Unfortunately, part number is not available in Brown



       

      How much weight can a 530 batten holder hold for a DIY pendant light?

      The 530 batten holder can be used in a pendant situation.
      However the 530 is normally attached to a lamp shade (or equivalent) where the lamp shade takes the weight.
       
      The 530 according to standards needs to withstand 5nm of force which equated to about 0.5kg
       

      What colour is the PDL 537, Standard deep mounting block (fits all 600/500 Series), available in?

      The PDL 537 is available in white (WH) and black (BK)

      Code example: Black PDL 537 - PDL537BK

       

      What size cut out is required for the PDL 533 Panel Mounting Clip?

      The clip requires a 30mm square hole as per the 600 Series/500 Series Brochure (PG 45).
      Please see the brochure attached for more information.

      Can I mix a Quantum 140CPU53414A with a 140CPU53414B in the same Hot Standby System?

      No. The Quantum hardware models must match in a Quantum Hot Standby System. A Hot Standby System must have two 140CPU53414A or two 140CPU53414B CPU modules.

      What is the mounting block and mounting bracket to suit the PDL 688VH and PDL 689VH ?

      Both suits 567S Mounting Block and 558 Mounting Bracket

      Is Power Monitoring Expert 508 compliant?

      Issue
      User would like to know if Power Monitoring Expert (PME) is 508 compliant.

      What is 508 Compliance?
      508 compliance means that all users, regardless of disability status, can access technology. Compliance standards are set by Section 508 of the Rehabilitation Act of 1973 that requires federal agencies to provide software and website accessibility to people with disabilities.
      When websites are 508 Compliant, they are accessible to all users. This can mean that they are compatible with assistive technology, such as screen readers.

      Product Line
      Power Monitoring Expert

      Environment
      Power Monitoring Expert Web applications

      Cause
      Customer needs to know if PME is 508 Compliant

      Resolution
      PME 8.2 is currently not 508 Compliant but may be compliant in a future version of software.


       

      Do you do a 238 mounting block with a 50mm entry?

      No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

      Does Clipsal do a 238 with 25mm entries, top and bottom?

      No we don't. The closest we get is the 238A/25 with one 25 entry on the top.

      What is the part number for a 238 in black?

      The part number for a 238 in black is 238-BK.

      Some of the key features are:
      • 1 gang
      • 84 mm mounting center
      • Horizontal and vertical mounting direction
      • 2 way
      • Suitable for 1 outlet
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238




       

      Is there a master key for the 568 series

      No there is not, if you want the keys to be the same you need to order the common key version PDL 568CK

      Do any of the PDL mounting blocks come in black?"

      Yes, the PDL 89, 530, 536, 537, 531, 538, 567S and 567L mounting blocks come in black.

      • The #/* key in the PDL Pocketbook indicates what colours are availbable.
       

      Source upload/download is not possible. Why ?

      Check the 2 following points :
      - M238 needs to be stopped before attempting a source upload or download.
      - Maximum project archive file ("Archive.prj") size is 0x90000 bytes (about 588 kB).

      What is the air flow of the 6500ADS?

      The air flow of the 6500ADS is 338 cubic meters per hour or 290 cubic meters per hour if you have a backdraught shutter fittered.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=6500ADS

      What is the Socket Interior for a WMB532 5 pin 32A outlet?

      The Socket Interior for a WMB532 5 pin 32A outlet is a SP-116481.

      What material is used in and what is the surface treatment for the ZB2Bxx fastening screws?

      These screws are made of Chromated class 5.8 steel.

      For RoHS compliant products please use the Harmony 4 or 5 ranges 

      What is the code for the 240VAC Coil for the LC1D32 Contactor ?

      Part Code = LXD1U7 
      The LXD1U7 also fits the LC1D09 - D38 Contactors

      What is the part no for an architrave single power point in PDL 600 series?

      The part no is PDL698WH

      https://www.clipsal.com/Trade/Products/ProductDetail?catno=698

      Key Features

      • Worktop single switch
      • Frquency rating: 50 Hz
      • Suits Cat 567S mounting block and Cat 558 mounting bracket
      User-added image
       

      Does Clipsal have a 1438 in 20 amp?

      No, but we have a 438 in 20 amp or there is the 56 series which could do the job.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/20 

      What are the dimensions for remote keypad for the ATS48?

      Issue:
      What are the dimensions for remote keypad for the ATS48?

      Product Line:
      Altistart 48

      Environment:
      All

      Cause:
      N/A

      Resolution:
      Width = 2 5/8 inches
      Height = 4 1/4 inches
      Depth = 5/8 inches
      This includes a clear membrane cover and a trim bezel.

      What can cause the laminate on a NetShelter CX to peel and how can it be fixed?

      Issue:
      The laminate on a NetShelter CX has begun to peel.

      Product Line:
      NetShelter CX
       
      Environment:
      All versions and serial ranges.
       
      Cause:
      Excessive heat or poor adhesion can cause the laminate to peel.
       
      Resolution:
      Replace entire panel or re-apply using contact adhesive and brush. Recommended contact adhesive - EVO-Stick 528 or equivalent.

      Which SCEM card is associated with each series of recloser/sectionalizer?

      Product Line
      Recloser

      Resolution
      Refer to the below table:

      Resloser Series SCEM Card
      N Series (up to 27kV) SCEM 11A
      N Series (38 kV) SCEM 11C
      U Series  SCEM 11B
      W Series SCEM 11D
      RL Series SCEM 12

      Are the LC1D40 thru LC1D150 Available With a Low Consumption DC Coil?

      Issue: 
      Looking for a higher amperage rated contactor with lox consumption dc coil.

      Product Line:
      Contactors and Starters

      Environment:
      D-Line Contactors
       
      Resolution: 
      No. Low consumption coils are available only on LC1D09 thru D38 contactors.

      CM4000/Accessory UL 508 Certificate of Compliance

      See attached documentation.
      EXT_UL508_Cert_CM4.PDF


      Legacy KB System (APS) Data: RESL205055 V1.0, Originally authored by MaTh on 04/12/2011, Last Edited by MaTh on 04/12/2011
      Related ranges: CM4000 series

      Is there a ceiling mounted battern holder available?

      Yes, the part number is 2530.
      Batten Holders, Note: The 2530 Series range of batten holders have been redesigned and are replacing 530 and old 2530 Series products, Batten holder BC straight with Clip-on cover.

      For further information please see https://www.clipsal.com/Trade/Products/ProductDetail?catno=2530
       

      Does the 56AI320 have round or flat pins?

      The 56AI320 is not available with flat pins.

      Some of the key features are:
      • 3 round pins
      • 204 mm Height x 101 mm Width x 138 mm Depth
      • 2.5 - 6 mm conductor terminal

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56AI320
       

       

      Changing Power Flow Sign remotely on a Compact NSX

      For remote sites there is a way of connecting remotely to a Micrologic unit to change the Power Flow Sign.
       
      On page 118 of the following user guide is talks about Power Flow Sign and has a command code of 47240. This configures the power flow sign.

      https://www.schneider-electric.com/en/download/document/DOCA0091EN/

      Page 138 of the same guide explains how to do this configuration.

       

      Are the 8940 Pump Panels available with a non-fused disconnect?

       Issue:
      Trying to order an 8940 pump panel, but they do not want incoming overload protection. 

      Product line:
      8940 Type S NEMA starter pump panels

      Environment:
      all

      Cause:
      Application adjustments

      Resolution:
      The 8940 panels are provided as Service Entrance rated devices.  As such, they are required to use overload protection on the incoming power wires.  If non fused entry is desired, consider using a 8538 Combination starter.

       

      I have an LC1D TeSys D-Line contactor. Which are the coil terminals?

      Issue:
      I have an LC1D TeSys D-Line contactor.  Which are the coil terminals?

      Product Line:
      D Line contactors.

      Environment:
      Products sold in the United States.

      Cause:
      Product features.

      Resolution:
      The coil terminals are the ones labelled A1 and A2.


      CTA-ID : 2011973

      Will the WallBotz 500 work with POE?

      <b>Issue:</b> 
      <br />
      <br />
      Will the NetBotz 500 work with POE?
      <br />
      <br />
      <b>Product Line:</b> 
      <br />
      <br />
      NetBotz
      <br />
      <br />
      <b>Environment: </b>
      <br />
      <br />
      NetBotz 500
      <br />
      <br />
      <b>Cause:</b> 
      <br />
      <br />
      The WallBotz 500 requires 3.3 and 5 volt power leads and draws more power than the Power Over Ethernet (POE) standard supports
      <br />
      <br />
      <b>Resolution:</b> 
      <br />
      <br />
      There is no workaround for this. The power supply provided with the NetBotz 500 must be used.
      <br/>
      <br/>

      How does the underload time delay work on the ATV12 drives?

      Issue:
      How does the underload time delay work on the ATV12 drives?

      Product Line:
      Altivar ATV12

      Environment:
      All

      Cause:
      Wants to know the underload time delay works.

      Resolution:
      I/O menu page 53: The Application underload time delay ( ULt) is the time delay before the underload fault occurs. It is adjustable from 0 to 100 secs.
      The Application Underload threshold is set to a certain percentage of the FLA of the motor  ( from 20 to 100 of the FLA) that you want the drive to fault.
       

      :


       

      Is there a fixed angle batten holder available?

      Yes, the fixed angle Batten Holder is a  531. There is also an angled adaptor to suit 530 and 2530 series batten holders which is a 530AWP.

      Some of the key features are:
      • 250W
      • With built-in fastening Ppugs and screws
      • Easily removable cover by 120 deg rotation and visual indicators
      • Front access to terminal slots allowing easy adjustment of terminals, even after installation
      For further information please visit https://www.clipsal.com/Trade/search-results?q=batten%20holders&p=1
       

      Is there an insulated version of 450VC vertical corrugated iron mounting block?

      Unfortunately, we do not have an insulated version of 450VC. Depending on the requirement we have 238 mounting boxes or the black plastic insulating shroud which can be used with 450VC. Customer needs to ensure they are following the wiring regulation. 

      For further information, please visit 
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=238 
      https://www.clipsal.com/Trade/search-results?q=insulating%20shroud


      238

      Are external motor overloads needed when running the motor with ATS46 softstart?

      Issue: Are external motor overloads needed when running the motor with ATS46 softstart?
       
      Product Line: ATS46
       
      Environment: All
       
      Cause: N/A
       
      Resolution: The ATS46 has integrated motor thermal protection.
      The thermal overload class can be adjusted to provide Class 2, 10, 10A, 15, 20, 25 or 30 overload protection as defined per IEC 947-4-2. The thermal overload protection may be turned off if external protection is provided.
      External overload protection may be provided if there are multiple motors or if there is full voltage bypass available.


       

      What minimum voltage is it possible to use ATV68, when switching-off protection “undervoltage”?

      Goals and Symptoms

      What minimum voltage is it possible to use ATV68, when switching-off protection undervoltage? Thank you very much for your help.

      Facts and Changes

      ATV68,

      Causes and Fixes

      400 V range = 287 V
      500 V range = 346 V
      690 V range = 537 V

      If the control is supplied with an external source 24V, if the voltage goes under the guarantied range, and if the fault undervoltage is deactivated (E3.08), the drive is going to supply the motor in downgraded operation (speed reduction, current limitation...) as long as no other fault appears.


      Legacy KB System (APS) Data: RESL161862 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Altivar 68

      What is the air flow rate in the 6600A?

      The air flow rate for the 6600A is 338 cubic meters per hour.
      Unfortunately there are 2 diffrent airflow rates listed, however 338 Cubic meters is the correct output.
      The En Suite is suitable for small bathrooms and en suites with ceilings of height 2.7 metres and above. The En Suite is also suited to small kitchens, toilets and laundries. Included in these neat and compact three-in-one combination units are two 275 Watt radiant heat globes, one 14W CFL central reflector globe and a high performance exhaust fan.
      Some of the key features are:
      • 264 mm Width
      • Room protrusion 60 mm
      • External protrusion 200 mm
      • Duct size dia. (E) 200 mm
      • Hole size 325 (395) x 240 mm
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=6600A
       

      Netbotz and FTP Return Codes

      Issue:

      Netbotz and FTP Return Codes

      Product Line:

      NetBotz

      Environment:

      NetBotz ftp codes

      Cause:

      When configuring the FTP Alert Action on a Netbotz device, the FTP server may return error codes which may viewed in the Appliance Log. The return codes may be used to further troubleshoot the problem.

      Resolution:

      The return codes for FTP servers are:

      110 Restart marker reply. In this case, the text is exact and not left to the particular implementation; it must read: MARK yyyy = mmmm where yyyy is User-process data stream marker, and mmmm server's equivalent marker (note the spaces between markers and "=").

      120 Service ready in nnn minutes.

      125 Data connection already open; transfer starting.

      150 File status okay; about to open data connection.

      200 Command okay.

      202 Command not implemented, superfluous at this site.

      211 System status, or system help reply.

      212 Directory status.

      213 File status.

      214 Help message.On how to use the server or the meaning of a particular non-standard command. This reply is useful only to the human user.

      215 NAME system type. WhereNAME is an official system name from the list in the Assigned Numbers document.

      220 Service ready for new user.

      221 Service closing control connection.

      225 Data connection open; no transfer in progress.

      226 Closing data connection. Requested file action successful (for example, file transfer or file abort).

      227 Entering Passive Mode (h1,h2,h3,h4,p1,p2).

      230 User logged in, proceed. Logged out if appropriate.

      250 Requested file action okay, completed.

      257 ""PATHNAME"" created.

      331 User name okay, need password. 332 Need account for login.

      350 Requested file action pending further information

      421 Service not available, closing control connection. This may be a reply to any command if the service knows it must shut down.

      425 Can't open data connection.

      426 Connection closed; transfer aborted.

      450 Requested file action not taken.

      451 Requested action aborted. Local error in processing.

      452 Requested action not taken. Insufficient storage space in system.File unavailable (e.g., file busy)

      500 Syntax error, command unrecognized. This may include errors such as command line too long.
      501 Syntax error in parameters or arguments.

      502 Command not implemented.

      503 Bad sequence of commands.

      504 Command not implemented for that parameter.

      530 Not logged in.

      532 Need account for storing files.

      550 Requested action not taken. File unavailable (e.g., file not found, no access). (550 a:: no such directory means no diskette in a: drive.)

      551 Requested action aborted. Page type unknown.

      552 Requested file action aborted. Exceeded storage allocation (for current directory or dataset). 553 Requested action not taken. File name not allowed.
       

      What are the product standards for the CM4000?

      Issue
      The UL listing for the CM4000

      Product Line
      CM4000

      Environment
      Standard Compliance

      Resolution
      For safety, the CM4000 is UL 508 for the USA. It's listing is cUL and UL listed 18x5 Ind. Cont. Eq. This information is listed in the CM4000 IB under the specifications. This can be found on page 8 of the attached document

      What is the catalog number for a replacement Vario switch for the VC*GU?

      Issue:
      Vario replacement switch

      Product Line:
      UL 508 Motor Disconnect Switches

      Environment:
      Mini-Vario and Vario™ Assembled and Enclosed Switches

      Resolution:
      Select replacement from table below:

      Enclosed   Switch Only
      VC1GU        V1
      VC2GU        V2
      VC3GU        V3
      VC4GU        V4
      VC5GU        V5
      VC6GU        V6

      Can an auxiliary contact be added to the VC_GU non-metallic enclosed Vario load break switch?

      Issue:
      Vario auxiliary contact

      Product Line:
      UL 508 Motor Disconnect Switches

      Enviroment:
      Mini-Vario and Vario™ Assembled and Enclosed Switches

      Resolution:
      Yes, however this will require removing one of the two grounding straps provided inside the enclosure box to allow room for mounting the auxiliary.

      What is the Difference Between Standard and low consumption TeSys D DC Coils?

      Issue:
      What is the Difference in Consumption Between the Standard DC Coils and the Low Consumption DC coils in the LC1D09 to D38 Contactors?

      Product Line:
      IEC contactors and starters

      Environment:
      Tesys D Contactors

      Resolution:
      The standard DC coils have a 5.4W burden, and the low consumption coils have a 2.4W burden for the LC1D09 to D38.