Angled image of 503M lampholder bc 2 pin wirh 20mm conduit thread

Lamp Holders, Lampholder BC With safety skirt 20mm Conduit Thread

Catalogue Number: 503M
Angled image of 503M lampholder bc 2 pin wirh 20mm conduit thread
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
BC lamp holder adaptor
Provided equipment
  • lamp holder
  • cap
  • skirt
    • Fixing mode
      by screws
      EU RoHS Directive
      Compliant
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Leaflet

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Do Clipsal have a 503 series batten holder with 10mm thread ?

      Yes , the part number is 503e-we
      For more information on batten holders please visit the Clipsal web site on the link provided https://www.clipsal.com/Trade/search-results?q=batten%20holders

      What would be the part number for an Earth Clip, 16/20 mm.

      203M.
      Pressed Metal Conduit Fittings, Earth Clips, Water pipe adjustable earth clip 15 - 20mm or 1/2 - 3/4 inch.
      Please see following link under the documentation tab for full catalogue.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=203M

      What is the part number for a 50mm female and 50mm male bush?

      The part number for a 50mm female and 50mm male bush is - 281/50 & 281F50
      For further information , visit link below:-
      www.clipsal.com/Trade/search-results?q=281/50
      https://www.clipsal.com/Trade/search-results?q=281F50
      User-added image

       

      Web Applications Error: "Http Error 503. The service is unavailable."

      Issue
      When trying to access the application webpage, the following error occurs:
                         
      The following error is seen in Windows Application Event Viewer:
                         
                          The Module DLL HipISSEngineStub.dll failed to load. The data is the error.

      Product Line
      Power Monitoring Expert 7.2.x

      Environment
      IIS 7
      McAfee Anti Virus
      HipISSEngineStub.dll

      Cause
      Upon checking Application Pools in IIS Manager, it turns out the application pool has stopped.  However, the problem cannot be resolved by simply re-starting the application pool.  By doing so and accessing the web page, it will stop again.
                         

      If McAfee has recently been uninstalled, updated, or changed the installation somehow, there is probably still a reference to it in the ISAPI settings.  Refer to the following link for more information:

                kc.mcafee.com/corporate/index
                https://kc.mcafee.com/corporate/index?page=content&id=KB72677&actp=LIST

      Resolution
      Remove the reference to the MfeEngine in the applicationHost.config:

      1.  Navigate to: %windir%\system32\inetsrv\config

      2.  Open the file applicationHost.config as Administrator for editing in Notepad.

      IMPORTANT: make sure a copy of the original file is available before making any changes.

      3.  Edit the  globalModules section and remove the following line:
                <add name="MfeEngine" image="%windir%\System32\inetsrv\HipIISEngineStub.dll" />;

      4.  Edit the modules section and remove the following line:
                <add name="MfeEngine" />;

      5.  After editing the applicationHost.config file, save the file, then restart the IIS server using iisreset or by restarting the system.
       

      What are the cable part numbers for M340 IO modules with 40 pin connections ?

      The following M340 IO modules require preconfigured 40 pin connector cable with color coded flying leads.
      Table below shows module and cable part numbers.

       
      Discrete Module Connection Cable Part # Qty needed
      BMX DDI 3202 1 x 40 BMX FCW 303, 503, 1003 ( 1 )
      BMX DDI 6402 2 x 40 BMX FCW 303, 503, 1003 ( 2 )
      BMX DDM 3202 1 x 40 BMX FCW 303, 503, 1003 ( 1 )
      BMX DDO 3202 1 x 40 BMX FCW 303, 503, 1003 ( 1 )
      BMX DDO 6402 2 x 40 BMX FCW 303, 503, 1003 ( 2 )
      text text
      AnalogModule text
      BMX ART 0414 1 x 40 BMX FCW 301S*, 501S* ( 1 )
      BMX ART 0814 2 x 40 BMX FCW 301S*, 501S* ( 2 )
      * S suffix denotes shielded cable for Analog IO.

      Legacy KB System (APS) Data: RESL212360 V1.0, Originally authored by DiSa on 08/24/2013, Last Edited by DiSa on 08/24/2013
      Related ranges: Modicon M340

      What are the mounting centers  of the 530ES-WE

      The mounting centers 50mm

      Looking for a 63mm Clipsal Bush ?

      Clipsal only have up to 50mm - part number 281/50-GY

      What is the hole size for a Clipsal 753-WE infrascan

       The hole size is 50mm

      Looking for a 63mm Clipsal Bush ?

      Clipsal only have up to 50mm - part number 281/50-GY

      What is the lamp life of a DL1BA024?

      Issue:
      What is the lamp life of a DL1BA024?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      All incandesent lamps have an estimated life of 2000 hours.

       

      What are the 50mm and 75mm screws for the BSL plates?

      The part number for the 50mm screws are B25-FS and the part number for the 75mm screws are BSL25-FS

      What is the part number for skirting duct 50mm deep and 200mm high ?

      the part number for skirting duct 50mm deep and 200mm high is - PL50200D

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=PL50200D
       

      What is the part number for 50mm corrugated conduit in 25metre roll?

      The part number for 50mm corrugated conduit in 25metre roll is - 9050TCM-GY

      For further information, visit the link below:-
      https://www.clipsal.com/Trade/search-results?q=9050TCM-GY
      User-added image

      What is the part number for the slotted grey ducting 65mm x 50mm x L200mm?

      The part number for the slotted grey ducting 65mm x 50mm x L200mm is - AK2CD125 & cover - AK2CA6

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/AK2CD125

      What is the part number for a conduit j-box with 3 x 50mm entries?

      The part number for a conduit j-box with 3 x 50mm entries is - 252/50/3
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=252/50/3
      User-added image

      What is the part number for a square conduit J-Box with 1 x 50mm conduit entry ?

      The part number for a square conduit J-Box with 1 x 50mm conduit entry is - 252/50/1

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=252/50/1
      User-added image
       

      What is the part number for a Brass adaptor , 2 inch male to 50mm female?

      The part number for a Brass adaptor, 2 inch male to 50mm female is - 1235BSP50/50

      For further information visit link below:-
      https://www.clipsal.com/Trade/search-results?q=1235BSP50/50
      User-added image

      What is the cut out hole size for a CBUS motion detector 5753L

       The cut out hole size is 50mm

      What is the cut out for a DCDALMS360.

      The cut out is a 50mm round hole.

      Is there any 50mm corrugated conduit in orange in our range?

      No there is not anymore.

      L1 VME What size Fixing Screws for the PDL 600 Series are available?

      16mm, 30mm and 50mm Long 

      What is the part for Clipsal Square Junction box 50mm 1 way

      Code = 252/50/1-gy  
      Colour = Grey 

      What are the dimensions of the PDL144MT?

      96mm X 60mm X 50mm Deep.

       

      Osisense XC - Datasheet of the adapted limit switch XCMN2115T1L0

      Please find attached the datasheet of the adapted limit switch XCMN2115T1L0, using a special cable halogen free for railway equipments, complying to EN 50306 and EN 45545 standards. Cable lenght = 1m. This reference is available to order without any restriction. It is not in stock, it is produced at order reception by the assembly plant. A second similar reference exists with 50cm cable lenght only : XCMN2115T05L0.

      PME 7.2.x or 8.0 Web Application gives an "HTTP 503 Service Unavailable" error message when Reports is selected

      Issue
      The customer is receiving an "HTTP 503. The service is unavailable" error message when selecting the 'Reports' tab through Web Applications.



      Product Line
      Power Monitoring Expert 7.x / 8.x

      Environment
      Web Reports

      Cause
      If Microsoft Monitoring Agent with .Net Application monitoring is installed, the 'WebReporterAppPool' Application Pool within Internet Information services is not started and crashes if started manually.

      Resolution 1
      This resolution does not require removing Microsoft Monitoring Agent. Instead, it is uninstalled, then reinstalled via the command line using a switch that prevents the .Net Application monitorng from being installed.

      To do this:

      1. Uninstall Microsoft Monitoirng Agent from Control Panel -> Programs and Features
      2. Start a command prompt in the directory that includes the Microsoft Monitoring Agent installer (it's called MOMAgent.msi)
      3. Run MOMAgent.msi NOAPM=1

      Resolution 2
      Windows updates will install a tool named the "Microsoft Monitoring Agent".  This tool applies a policy to the application pool that causes it to crash.  Uninstalling the tool through Add/Remove programs will allow Web Reports to function as expected.

      Do you do a 238 mounting block with a 50mm entry?

      No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

      What is the Zen Cut out?

      The Zen series cut out is:
      • 76mm (L) x 50mm (W) for Horizontal
      • 76mm (W) x 50mm (L) for Vertical
      For further information on this product - Please visit https://www.clipsal.com/home-owner/products/powerpoints-switches/styles/saturn-zen

       

      Does Clipsal have a Link Bar with at 13 tunnels and 1 x 50mm and 3 x 16mm tunnels?

      Yes the L13/150 will suit those requirements.

      Is HFT rigid conduit available in 50mm

      Unfortunately 32mm is the highest HFT rigid conduit available

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=9032HF

      User-added image

       

      What is the setting depth behind the front plate and range for a PDL 100MPIR ?

      50mm deep - Forward range of 5 Meters - Field of view 100° Horizontal / 82° Vertical

      Is there a difference in depth of the swing frame cabinets to the non swing frame variants?

      Swing frame adds an ecxtra 50mm depth to cabinet.

      Is there an Internal Elbow for truning size 150 x 50mm Maxi Duct Drunking?



      No, largest internal elbow available is 900/100/100EI

      What is the cut out for a BSL switch?

      The cut out for a BSL switch is 73mm(L) X 50mm (W).

      Do you do the Transparent Inspection Tee up to 50mm?

      The 50mm Transparent Inspection Tee is a SC246/50-TR.

       

       

      What is the part number for a 80mm x 50mm service column?

      The part number for a 80mm x 50mm service column is MSC80503N.
      However this part is being phased out and replaced with the new Optiline 70 series.

      For more information, visit the website at www.clipsal.com/Trade/search-results and click on the link to view a brochure.

      What is the XD2PA4196640001 and XD2PA4196640002?

      Issue:
      What are the XD2PA operators? 

      Product Line:
      Harmony XD2

      Environment:
      US product

      Cause:
      These units have no documentation.  The XD2PA4196640001 is not in My Schneider.

      Resolution:
      The XD2PA419640001 is an XD2PA22 with a 50mm shaft.
      The XD2PA419640002 is an XD2PA24 with a 50mm shaft.

      According to datasheet, operating distance is "50m", and maximum sensing distance is "100m". What is a difference between these distance explanation?

      We speak about 100m in free field, we can guaranty a well functioning at 50m in industrial applications, actually it depends mainly of where the system is installed, for the moment no customer is complying about low range.

      Is the light stack cap included with a XVPC21 or XVPC21W ?

      Issue:
      Top cover for XVPC21

      Product Line:
      50MM Diameter

      Environment:
      Tower Lights and Beacons

      Resolution:
      Yes, the cap is included.

      Note: XVPC21 is obsolete.

      What thread are the 600 Series fixing screws?

      6/32UNC
      We no longer sell the tap, but these should be available from an engineering shop.
      The screws are available in 3 sizes 16mm (code 201), 30mm (code 202), and 50mm (code 204).

      What are the hole sizes for the BP165/7

      2 x 9.5mm - 50mm cable
      1 x 8.0mm - 35mm cable
      2 x 7.1mm - 25mm cable
      2 x 5.5mm - 16mm cable

      Do you have the a longer version of the standard mounting screws for your power points?

      Yes the part number for the longer screws is a 355A. They are 50mm long apposed  to the 355 which is 32mm long. Both screws are M3.5 X 0.8 Pitch.

      What are the basic part numbers I need for 50mm x 150mm skirting duct?

      The basic part numbers are the duct (PL50150DN), the lid (PL150CLN), the joiners (PL50ACC), power and data covers (PL150CFCN), power shrouds (PLPSK) and data shrouds (PLDSK). These are all in natural anodised colour.

      For more information, visit the website at www.clipsal.com/Trade/search-results and click on the link to view a brochure.

      What is the diameter of the mounting holes in 176HDGM?

      The 176HDGM is a 50mm saddle, and has the following dimensions.
      Length: 108mm
      Width: 25mm
      Height:53mm
      Hole Diameter: 6mm

      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=176HDGM&c=1&ms=5&mg=324&g=3244682

      User-added image

      What is the part number for the internal barrier for the PL50150D skirting duct?

      The part number for the internal barrier for the PL50150D skirting duct is PL50IB.

      Some of the key features are:
      • 2.4m Length
      • Duct size: 2400mm Length x 150mm Height x 50mm Depth
      For further information please visithttps://www.clipsal.com/Trade/Products/ProductDetail?catno=PL50IB

      What size cable can fit in the T100?

      Terminals of the T100 will accommodate from 10mm min, to 50mm max. cables.

      Some of the key features are:
      • Back wiring
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=T100

      What is the maximum motor distance for an Altivar 212?

      Issue:
      What is the maximum motor distance for an Altivar 212?

      Product Line:
      ATV212

      Environment:
      All serial numbers for ATV212

      Cause:
      N/A

      Resolution:
      The maximum motor cable length is 50m (164ft).  This maximum can be increased with the use of a motor choke.

      What are the part numbers for the Power and Feedback cables for a BMH1003 xxxxxx motor ?

      Issue: Part numbers

      Product Line: BMH

      Environment: None

      Cause:

      Resolution:

      The part number for the power cable for a BMH1003 xxxxxx motor is VW3 M5101 Rxxx . where xxx = 15, 30, 50, 100, 150, 200, 250, 500, 750 for cable lengths 1.5m, 3m, 5m, 10m, 15m, 20m 25m 50m and 75 m respectively, The composition of this cable is [(4 x 1.5 mm^2) + (2 x 1 mm^2)] and comes with a pre-made M23 style industrial connector on the motor end and free ends on the drive side.

      The part number for the feedback cable for a BMH1003 xxxxxx motor is VW3 M8102 Rxxx  where xxx = 15, 30, 50, 100, 150, 200, 250, 500, 750 for cable lengths 1.5m, 3m, 5m, 10m, 15m, 20m 25m 50m and 75 m respectively, The composition of this cable is [(3 x 2 x 0.14 mm^2) + (2 x 0.34 mm^2)] and comes with a pre-made M23 style industrial connector on the motor end and an RJ45 style connector on the drive side.

      How do i seal up a 50mm hole in the 230DRAVL?

      Using parts 220S50-GY and 260/50-GY. Placethe 260/50 on the inside and the 220S50 on the out side place it in the hole and screw them together. This willl then seal the hole.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=260/50
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=220S50
       
       
       

      What is the diameter and bend of radios of the cable VW3A1104R30?

      Issue:
      What is the diameter and bend of radios of the cable VW3A1104R30?
       
      Product Line:
      ATV61/71
       
      Environment:
      VW3A1104R30
       
       
      Cause:
      N/A
       
      Resolution:
      Response from France: 
      The diameter of the cable is : 5.6mm 
      The bending radius minimum is : 50mm

      What are the dimensions of the EVlink pedestal base?

      Issue:
      Layout of the pedestal base for mounting

      Product Line:
      PTEVC - Electric Vehicles

      Environment:
      Installation

      Cause:
      Unit is mounted to ground

      Resolution: 
      The Pedestal base dimensions (metric) are shown below and are also available in the Installation Manual for Outdoor EVlink stations.  Base dimensions are the same
      for all Level 2 pedestal offers.  Anchor bolts of 12.5mm (1/2") will easily fit the slotted openings provided and a 50mm (2") stub will fit the central opening.
      Pedestal Base Dimensions
      More information on our EVlink products here!