5000MP CLIPSAL

C-Bus Enhanced DLT Mounting Plate (Box of 5)

Catalogue Number: 5000MP
5000MP CLIPSAL
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
REACh free of SVHC
Yes
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
ENVEOLI1207002EN

Documents & downloads

hide show
Filter items
  • All

  • End of Life Manual

Frequently Asked Questions

hide show

Will the 5000MP suit the DLT and eDLT?

 The eDLT wall switch range will come with a plate (5000MP) but will be available seperately for 2nd fix. 5000MP is for the eDLT range. The DLT range is ok with standard wall plates and wall clips (154).
Please see following brochure link for more information.
https://www.clipsal.com/Trade/search-results?q=5000mp

What is the effect of altitude on ATV312?

Product Line:
All ATV312 and ATV31

Environment:
High altitude, more than 1000m

Cause:
What is the effect of the high altitude on the drive.

Resolution:
For all ATV312, less than 1000m, no derating.
For single-phase supplie and corner grounded distribution networks, up to 2000m, derateing 1% per 100m.
For three-phase supplies, up to 3000m, derating 1% per 100m.




 

What is the part number for a 300amp fuse carrier

We don't have a 300amp fuse carrier, the highest is 200A

Audited Energy Data Management System Certificate

Issue
Verify certain characteristics and functionalities (as stated in the attached certificate) within the framework of auditing.

Product Line
All power monitoring related software (PME, PSO, EBO, PA).
All power monitoring related hardware (i.e. power meters, energy meters, PQ meters, circuit breakers, protection relays).

note: complete list of products specified in the attachment

Environment
Auditing
Certificate

Cause
Compliance with ISO standards.

Resolution
Refer to the attachment.

Do you have a 2000MF round mounting block with a diameter of 800?

Yes the part number is 2000MF800.

What is the part number for Wilco range 400amp 5 pin plug?

Our range of Wilco plugs only goes to 200amps.

Do the 4000PP suit both the Saturn and Saturn Zen ranges?

Yes, the 4000PP will cover bother ranges.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=4000PP

What is the part number for a 300Amp AC1, 4 pole, contactor?

The part number for a 300Amp AC1, 4 pole, contactor is a LC1F225N7.

 

How many copper FIPIO or FIPWAY network segments can be joined into one copper FIP network and what is the total length possible?

Up to 5 copper FIPIO or FIPWAY network segments can be joined using either TSXFPACC6 (electrical) or TSXFPACC8 (optical) repeaters to get a total length of 5000m of copper cabling. Each individual segment is limited to 1000 meters in length. This figure includes all trunk cabling and all drop cabling.

Will the 2000pp fit the C2000 series?

No, unfortunately you will need to use a C2000PP paint protector.

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=C2000PP

What is the part number for a 3 pole 400amp INS load break switch?

The part number for a 3 pole 400amp INS load break switch is - 31110

For further information visit link below:-

https://www.schneider-electric.com.au/en/search/31110
User-added image

What is the part number for Saturn paint covers?

4000PP-TR ( sold as a pack of 250)

How much ceiling space is required for 6500ADS?

The 6500ADS has a minimum ceiling cavity space of 500mm.

What is the part number for a 1200mm weather proof LED fittings?

TPWPLED2 LED Weatherproof Batten, 40W, IP65, 5000K, 1200mm.

What is the part number for standard din rail?

The part number for standard din rail is NSYSDR200B. It is 7.5mm deep by 2000mm long.

What is the altitude derating for a TeSys D-Line contactor?

Issue:​
What is the altitude derating for a TeSys D-Line contactor?

Product Line:
Digest 177 Section 18 : Contactors and Starters, IEC

Environment:
North American Products

Resolution:
The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

Voltage
3500m x 0.90
4000m x 0.80
4500m x 0.70
5000m x 0.60

Current
3500m x 0.92
4000m x 0.90
4500m x 0.88
5000m x 0.86

For example, an LC1D80 at 5000 meters:
- The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
- The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



 

Do you have a 45RU data cabinet 800mm Wide X 1000mm Deep?

Yes, the part number is 3106N45C810-BK.

What is the part number for a 45RU data cabinet , 800mm wide and 1000mm deep?

The part number for a 45Ru data cabinet that has dimensions of W800m x D1000mm is - 3106N45C810

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3106N45C810

What is the part number for 100amp 3 pole Acti9 C/B , C-Curve?

The part number for a 3 pole 100amp acti9 C-Curve C/B is - A9N18367

For further information , please visit link below:-
https://www.schneider-electric.com.au/en/search/A9n18367

What is the part number for a 4 pole 100amp RCCB?

The part number for a 4 pole 100amp RCCB is - A9R21491
For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9R21491

What is the part number for a 1 pole Din mount 100amp isolator?

The part number for a 1 pole Din mount 100amp isolator is - SW1100

 

What is the part number for a 2 pole 100amp iC120 C/B?

The part number for a 2 pole 100amp iC120 C/B is - A9N18362

For further information, visit the link below:-
www.schneider-electric.com.au/en/search/A9N18362
User-added image

What is the part number for a 3 pole 100amp din mount isolator?

The part number for a 3 pole 100amp din mount isolator is - A9S66391

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9S66391
 

What is the part code for a NS breaker 3P 250Amp 40kA with 200Amp trip unit and fit busbar system

You can use an LV431406 frame with a LV431431 trip unit and also LV429372 busbar adaptor

What is the part number for a 3P 200amp front wired main switch

T200FA-BK this comes with cover
 
PDL Book page 124 (2014)

What is the part number for a panel mount 3 pole front wire 100amp main switch?

The part number for a panel mount 3 pole front wire 100amp main switch is - T100F

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=T100F
User-added image

What is the part number for a 3 pole 12 prong 100amp busbar unit for iC60 C/B's?

The part number for a 3 pole 12 prong 100amp busbar unit for iC60 C/B's is - A9XPH312

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9XPH312
User-added image

What is the part number for a panel mount 100amp changeover switch marked Mains - OFF - Emergency?

The part number for a panel mount 100amp changeover switch marked Mains - OFF - Emergency is - PS100CO-BK

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=PS100CO
User-added image

What is the part number for a 100amp three phase 24 prong busbar for iC60 C/B?

The part number for a 100amp three phase 24 prong busbar for iC60 C/B is - A9XPH324

For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/A9XPH324
User-added image

What is the part number an C120H 4 pole 100amp 15kA B-Curve C/B?

The part number a C120H 4 pole 100amp 15kA B-Curve C/B is - A9N18435

For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/A9N18435
User-added image

 

What is the maximum altitude an ATV61 or ATV71 series drive can be used at?

Issue:
What is the maximum altitude an ATV61 or ATV71 series drive can be used at?

Product Line:
Altivar 61, Altivar 71 series drives.

Environment:
All models, All serial numbers.

Cause:
Elevation vs current rating

Resolution:
The Altivar  61 and 71 series drives can be used at full rating up to 1000 meters above sea level. They must then be derated by 1% for every additional 100 meters up to a maximum of 3000 meters above sea level.
Note that the ATV61H***S6X and ATV71H***S6X drives must not be used with corner grounded systems at altitudes above 2000m.

What is the part number for PVC joining cement 500ml in blue colour, low vapour if possible?

Unfortunately, Low vapour is no longer available.
The part number for PVC joining cement 500ml in blue colour is - 240/500BU
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=240/500BU
User-added image

There is somthing confusing about the current derating with the altitude > 1000m. The data in catalogue is 2.2% per additional 100m while in manual ...

Goals and Symptoms

There is somthing confusing about the current derating with the altitude > 1000m. The data in catalogue is 2.2% per additional 100m while in manual is 0.5%.
Which one is right?

Facts and Changes

ATS48
Altitude

Causes and Fixes

These both values are bad. The real derating is 2% per additional 100 meter.


Legacy KB System (APS) Data: RESL156259 V3.0, Originally authored by on , Last Edited by on
Related ranges: Altistart 48

What is the part number for a 3phase 100amp 30mA trip RCD unit?

The part number for a 3 phase  ,100amp , 30mA trip RCD unit is - A9R21491

What is the part number for a 3 pole 100amp switch , made of Cast Aluminium , with IP66 rating?

The part number for a 3 pole 100amp switch , made of Cast Aluminium , with IP66 rating is - WMS3100
Some of the key feature are:
  • They can be mounted using internal or external options, depending on the application requirements
  • The metal clad range is made from high-grade aluminium, providing a lightweight, corrosion resistant industrial switchgear
  • Easy installation
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=WMS3100
User-added image

Can the EGX400 or ECC21 fiber port connect directly to a gigabit (1000 Mb) network?

Issue:
User would like to communicate with an EGX400 or ECC21 using a gigabit (1000 Mb) fiber network
 
Product line:
ECC21, EGX400
 
Cause:
Customer wanted to know if they can directly connect 1000Mb a gigabit) fiber connection to EGX400 or ECC21 fiber port?
 
Resolution:
Customer cannot connect a 1000Mb fiber connection directly to the ECC21 or EGX400.
As per the ECC21 and EGX400 Installation Manuals, the fiber port is compatible with 100Mb networks only.
If gigabit fiber network connections are needed, a 100Mb multi-mode LC fiber converter will be required. 

Alternately, a gigabit fiber switch with 10/100/1000 copper ethernet connections could be used. In this instance, the fiber would be run to the switch and 10/100 ethernet to the EGX or ECC gateway.
 

Is it possible to mount a weathershield power point on a pole ?

Weather shield enclosure will line up with the 2000MF range, screw mountings will go on an angle to the pole, opposing the enclosure and may be tricky.
Available standard as white. If diameter surface is less than 300mm you may be able to use a 56PMK.
2000MFV range has a large amount of variable for different sized diameter surfaces.
Please see following link for complete range of sizes
https://www.clipsal.com/Trade/search-results?q=2000mf
 

What is the part number for a 2 pole 50amp C/B for 24VDC ?

The part number for a 2 pole 50amp C/B for 24VDC is - A9F44250.

For further information go to link below:-
https://www.schneider-electric.com.au/en/search/A9F44250

What is the part number for a D-Curve 3 pole 50amp C/B?

The part number for a D-Curve 3 pole 50amp C/B is - A9F55350

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9F55350
User-added image

What is the part number for a 56 series 5 pin 50amp socket outlet?

The part number for a 56 series 5 pin 50amp socket outlet is - 56SO550

 

What is the part number for a 1 pole 50amp Square D circuit breaker?

The part number for a 1 pole 50amp Square D circuit breaker is - QO150VSC10

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/QO150VSC10
 

100amp 6kva c curve 1pole MCB ?

 
not availible 
 6ka in 100amp, need to be 6ka

need to go up to 10ka
A9N18358

Communication issue 174CEV30010 or 174CEV30020 Modbus to Ethernet bridge over an RS232/RS485 network.

I need to take devices off-line for maintenance on my RS232/RS485 network and I am using a CEV30010 or CEV30020 Modbus to Ethernet bridge. I notice that if I take a serial device off-line, it affects other devices that have Ethernet to Modbus communications through the bridge. What can I do?

Decrease your Modbus Message Time Out value. As only 1 outstanding Modbus message is allowed on the serial side of the network, the default timer of 5,000ms (5 seconds), will have to expire before the subsequent message in the queue will be sent.


What is the part number for a 6RU 500mm deep swing frame cabinet?

The part number for a 6RU 500mm deep swing frame cabinet is a 3106WS06C605.
Some of the key feature are:
  • Welded Frame
  • Powder coated- RAL 7035 (light grey)
  • Front and rear mounting rails supplied
  • Top and bottom cable entry points
  • Framed 4.5mm Glass/ Lockable front door

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=3106WS06C605

What is the part number for a 4 pole 50amp B-Curve C/B with Shunt release?

The part number for a 4 pole 50amp B-Curve C/B with Shunt release is - A9F53450 & A9A26946

for further information , visit links below:-
https://www.schneider-electric.com.au/en/search/A9F53450
https://www.schneider-electric.com.au/en/search/A9A26946
User-added image

What is the part number for a 3 pole 50amp 56 series isolator with common key?

The part number for a 3 pole 50amp 56 series isolator with common key is - 56K2SW350CK

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56K2SW350CK
 

What is the part number for a 56 series double pole 50amp surface switch?

The part number for a 56 series double pole 50amp surface switch is - 56SW250

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=56SW250
User-added image

Is the telephone cable 2T25PIPV sold per meter or per box length?

The telephone cable 2T25PIPV is sold per meter and can be done on lengths of up to 500m.

What is the part number for 4 pin 50amp cast aluminium switched outlet

The part name is as follows: WMC450

MTBF and Lifetime of the XBTGT/GK range

Goals and Symptoms

What are the MTBF of the XBTGT & XBTGK?

Causes and Fixes


XBTGT2330:
Lifetime: 50000 hours
Mean Time Between Failures : 12418 hours
... (see attached files for all details)
XBTGT5330:
Lifetime: 50000 hours
Mean Time Between Failures :7644 hours


XBTGK2120:
Lifetime: 50000 hours
Mean Time Between Failures : 13058 hours
XBTGK2330:
Lifetime: 50000 hours
Mean Time Between Failures :8673 hours
XBTGK5330:
Lifetime: 50000 hours
Mean Time Between Failures : 6031 hours
(see attached files for all details)

Attachments

(Removed File URL: 177318_B4E6/MTBF_all_xbtgt.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/f627976801cfe634c12574560052adbb/fl_block_5/0.1338?OpenElement&FieldElemFormat=gif)(Removed File URL: 177318_B4E6/XBTGK.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/f627976801cfe634c12574560052adbb/fl_block_5/0.20B6?OpenElement&FieldElemFormat=gif)


Legacy KB System (APS) Data: RESL177318 V2.0, Originally authored by JaOu on 05/27/2008, Last Edited by DaBr on 05/27/2008
Related ranges: Magelis XBT GK, Magelis XBT GT