Specifications

hide show
Range
Clipsal - Series 4
Product or component type
residual current breaker with overcurrent protection (RCBO)
Product brand
Clipsal
Poles description
2P
Number of modules
2
[In] rated current
25 A
Curve code
C
Earth-leakage sensitivity
30 mA
Earth-leakage protection class
class AC
Breaking capacity
6 kA
[Ue] rated operational voltage
240 V AC
[Uimp] rated impulse withstand voltage
4 kV
Size
81 x 36 x 77.5 mm conforming to DIN 43880
Standards
AS/NZS 61009
IP degree of protection
  • IP20
  • IP40
    • Ambient air temperature for operation
      -5-40 °C
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120401EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Product Environmental

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Does 4RCBM220/30 switch both active and neutral?

       4RCBM220/30 will switch both active and neutral.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=4RCBM220/30

      What is the replacement for part number 4RCBM220G30?

      4RCBM220SI30 is the replacement for part number 4RCBM220G30. 4RCBM220SI30 is RCD/MCB, 2 module, 2 Pole, 20A, 30mA, 10KA, C-Curve SI-type, super immune,  A-type, surge current protected to 3000 A 8/20ms.
      For further information, please refer to the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM220SI30
      User-added image
       

      What is part number for Resimax Busbar to suit RCBM216/30?

      RCBM216/30 can be used with RMXPH105,RMXPH112 or RMXPH124.

      Looking for a 10mA 20A RCBO.

       Part code is 4RCBE220/10

      What are the dimensions for the 4RCBE220/30S?

      The dimensions for the 4RCBE220/30S are - L93mm x D72mm x W18mm

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=4RCBE220/30S
       

      Is the part 4RCBE220/30S still available?

      Yes

      What is the part number for a 2 pole 16amp 10kA RCBO?

      The part number for a 2 pole 16amp 10kA RCBO is - 4RCBM216/30

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=4RCBM216/30

      User-added image

      Is the RCBM210/30 an RCD only ,or is it a combination RCD/MCB?

      The RCBM210/30 is a combination RCD/MCB.

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=RCBM210/30
      User-added image

      Can part number 4RC425/30 be operated without neutral?

      The 4RC425/30 can be operated without neutral through resistor.

      Do you do a 3 pole version of a 4RCBM232/30?

      Unfortunately we do not offer a 3 pole version of a 4RCBM230/30.

      However as an alternative we can offer a A9F54432 (4 Pole 32A Circuit Breaker) and a A9V06763 (Vigi Block).

      For further information please visit www.clipsal.com/Trade

      Are the RCBM series of RCBOs double pole isolating?

      Yes they are.

      what is the KA rating 4rcbm232/30.

      For this 4RCBM series  range the KA rating is above 25a is limited to 6KA and below 25amps is 10ka.

      Replacement for the 4RCBE110/10

      This part has been replaced with 4RCBE210/30S

      What is the alternative to the 4RCBE210/30?

      Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

      What is the part code for a 40A 2P 10mA RCD

      Use a 4RCBE240/10 RCBO

      What does the yellow warning label adjacent the bottom neutral terminal indicate on a RCBE220/30S?

      Please refer to the attached literature for details.

      Is the RCBM216/30 fed from the top or the bottom?

      The RCBM216/30 line and load terminals may be connected to either the top or bottom for ease of installation.

      Some of the key features are:
      • Separate RCD trip flag for easy fault finding
      • New insulated openings for easy busbar installation
      • No need to cut the busbar providing safe and quick fit off
      • Top and bottom line load compatible for easy installation

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=RCBM216/30

      What is the part code for a 56 Series with a 32a 10ma RCBO

      Part codes you need a PDL 56CB4  with a 4RCBE232/10

      What is the part code for a 10A 1phase Socket protected by 10mA RCD

      You can use 56SO310 +56CB4 + 56E3 + 4RCBE210/10

      What is part number for 2pole 10ma 16amp MCB/RCD?

      Part no 4RCBE216/10

      What is the part number for a 20A, 10mA RCB?

       The part number is 4RCBE220/10s

      What is the part number for replacement 40amp RCBO - 4RCBE140/30?

      The part number for replacement 40amp RCBO - 4RCBE140/30 is - A9D11840

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/+A9D11840
       

      What is the replacement for a 4RCBE110/30?

      The replacement for a 4RCBE110/30 is a A9D61810.
      Some of the key features are:
      • 2 Pole wide
      • 30mA
      • 10A
      • RCBO
      For further informatio please visit www.clipsal.com/Trade/Products/ProductDetail?catno=A9D61810

      What is the part code for an RCBO 10mAmp 20Amp needed for a school

       The part code is a 4RCBE220/10.

      What size cables fit into the 4CB3125/10?

      If the cable is Rigid/ Semi Rigid the 4CB3125/10 breaker will take a cable from 1mm²- 50mm².

      OR

      If the cable is Flexible or Ferrule the 4CB3125/10 breaker will take a cable from 1.5mm²- 35mm².

      Do Clipsal have a 20a single module RCBE @ 10ma suited for hospital use ?

       
       
       
       
      Yes we do , In this case it would be the 4RCBE220/10S.
      To be approved for use in hospitals the RCBO must be approved as "Type 1" (ie: 10mA sensitivity, switch both Neutral and Active, and trip in <40ms)
      The below range of Slimline RCBO's are rated as Type 1 and therefore compatible


      For more information on Clipsal Circuit protection please visit the Clipsal web site on the provided link https://www.clipsal.com/Trade/search-results?q=circuit%20protection

      Do 4RCBE220/10S suit Schneider chassis?

      4RCBE216/10S does NOT fit onto a standard Chassis.
      reason is the two small terminal screws for active and neutral do not match  the tee off spacing 

      What is the part number for residential 40A combo RCD & CB?

      The part number for residential 40A combo RCD & CB is a 4RCBM240/30.
      Some of the key features are:
      • Seperate RCD trip flag for easy fault finding
      • new insulated openings for easy busbar installation
      • No need to cut the busbar providing safe and quick fit off
      • Same base module as the 10ka mcb, uniformity in space requirements and installation
      • Same housing and installation features as the mcbs. Safe, easy and fast installation
      • Top and bottom line and load compatible for ease of installation
      • Labelled terminals. Safe, easy and fast installation
      • Top and bottom clip allowing dismounting with comb busbar in place
      • Busbar compatible through an insulated slot
      • Surge current protected to 250a 8/20μs/li>
      • Operating temperature: -5 to 40 deg C
      • Standard type
      • 1-phase
      • 4 kV Rated impulse withstand voltage
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM240/30






       

      What is the part number for a 20A RCBO double pole?

      The part number for a 20ARCBO double pole is 4RCBE220/10.

      What is the part number of the replacement RCD to suit 56SC520RC?

      4RC425/30 can be used as a replacement RCD for 56SC520RC. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC425/30

      What are the dimensions of the RCBM216/30?

      The dimensions of the RCBM216/30 are 44mm(D) X 81mm(H) X 36mm(W).
      Some of the key feaures are:
      • Seperate RCD trip flag for easy fault finding
      • New insulated openings for easy busbar installation
      • No need to cut the busbar providing safe and quick fit off
      • Top and bottom line load compatible for easy installation
      • Operating temperature: -5 to 40 deg C/li>
      • Mechanical combination Standard-type
      • 4 kV Rated impulse withstand voltage
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=RCBM216/30
       

      What is replacement for part number 4EL25/4/30?

      Part no 4EL25/4/30 has been replaced with 4RC425/30.

      Whats the part number for a 10mA, 20A RCD MCB?

      The part name is 4RCBE220/10S

      What is the alternate to part number 4EL25/2/30, 25A , 30mA, 2 module RCD?

      4RC225/30 is an alternate for 4EL25/2/30, 25A , 30mA, 2 module RCD.

      Key Features

      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure
      • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
      • Same housing as AC type MCBs. Uniformity in space requirements and installation
      • Superior, safe and reliable DC breaking per pole
      • Used with marine, telecommunications, solar power, emergency power, battery power
      • Excellent breaking capability for its compact size
      • Standard type
      • 75 mm modular spacing
      • Surge current protected to 250 A at 8/20 uS
      • Operating temperature: -5 to 40 deg C
      • Degree of pollution is 2
      • Rated Impulse withstand voltage is 6 kV

      https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC225/30

      What is the replacement for 4EL40/2/30?

      The replacement part name is 4RC240/30

      Is there a 32A super immune RCBO?

      Yes the part number is a 4RCBM232SI30. this is commonly used with motors, pumps and generators as it is more immune to voltage spikes resulting in less nuisance tripping.
       

      What is the part number for the bus bar to suit the 4RCBE216/30S slim line RCBO ?

      The combination Busbars to suit the slim line RCBO's are the  21501 (12 pole) or 21503 (24 pole)
      For more information on this product range please visit the Clipsal web site on the link provided.
      https://www.clipsal.com/Trade/search-results?q=4rcbe210/30s
       

      What is the replacement for a 4EBE220/30?

      The replacement for a 4EBE220/30 is a RCBM220/30.
      Some of the key features are:
      • Seperate RCD trip flag for easy fault finding
      • New insulated openings for easy busbar installation
      • No need to cut the busbar providing safe and quick fit off
      • Top and bottom line load compatible for easy installation
      • Operating temperature: -5 to 40 deg C/li>
      • Mechanical combination Standard-type
      • 4 kV Rated impulse withstand voltage
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=RCBM220/30

       

      Does the 4RCBE216/30S swittch the neutral as well as the active?

      Yes, the two pole safety feature allows switching of both active and neutral contacts.

      Some of the key features are:
      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBE216/30S
       

      Is there a replacement for 4RCBE116/30Q Quicklag 16A RCBO?

      Unfortunately not,  we do not have a replacement for 4RCBE116/30Q Quicklag 16A RCBO.

      is the 4RCBE210/10S and similar a Type 1 RCBO used for hospital applications ?

      In hospital applications, Type1 RCBO must be used.

      4RCBE210/10S is a type 1 RCBO. However it is different to the one used in medilec panels.

      Is there an alternate part number for 4RCBE120/30H, Heinemann CF1 MCB replacement?

      Unfortunately not. We do not have a replacement for 4RCBE120/30H. None of Clipsal's current range of RCBO's can be used as a replacement for Heinemann CF1 MCB.
       

      Do you have a 10A RCBO double pole and 1 module wide?

      Yes, we do have a 10A RCBO double pole that is 1 module wide. The part number is RCBE210/30S.

      What is part number for 20amp 10ma single module RCD/MCB?

      The part number for 20amp 10ma single module RCD/MCB is a 4RCBE220/10S.

      Can I connect the line to either end of a 4RCBE216/30S?

      Yes, the 4RCBE216/30S is top and bottom line and load compatible for ease of installation.

      Some of the key features are:
      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBE216/30S

      What bus bar would I use with the RCBE220/30S?

      You would use the RMXPH124.

      Some of the key features are:
      • SLIM Comb busbar is optimised for the SLIM RCBO
      • Resi MAX comb busbar reduces wiring effort, makes wiring easy and installations time efficient
      • Save valuable switchboard space with the SLIM RCBO, a 2 in 1 RCBO system in a thinner module
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=RMXPH124

       

      What is the part number for a single module RCBO 32a 10mA

       
       
       
       
      The part number is 4RCBE232/10S

      What is the closest alternative to a 4RC425A30?

      The closest alternative to a 4RC425A30 is a 4RC425SI30.
      Some of the key features are:
      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure
      • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
      • Same housing as AC type MCBs. Uniformity in space requirements and installation
      • Superior, safe and reliable DC breaking per pole
      • Used with marine, telecommunications, solar power, emergency power, battery power
      • Excellent breaking capability for its compact size
      • Super immune type
      • 75 mm modular spacing
      • Operating temperature: -5 to 40 deg C
      • Degree of pollution is 2
      • Rated Impulse withstand voltage is 6 kV
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RC425SI30






       

      What is the closest alternative to a 4EBEM220/30, 20A 30mA, double pole, RCD?

      The closest alternative is a 4RCBM220/30 which is a 20A, 30mA, RCD MCB.

      Some of the key features are:

      • Seperate RCD trip flag for easy fault finding
      • new insulated openings for easy busbar installation
      • No need to cut the busbar providing safe and quick fit off
      • Same base module as the 10ka mcb, uniformity in space requirements and installation
      • Same housing and installation features as the mcbs. Safe, easy and fast installation
      • Top and bottom line and load compatible for ease of installation
      • Labelled terminals. Safe, easy and fast installation
      • Top and bottom clip allowing dismounting with comb busbar in place
      • Busbar compatible through an insulated slot
      • Surge current protected to 250a 8/20μs
      • Operating temperature: -5 to 40 deg C
      • Standard type
      • 1-phase
      • 4 kV Rated impulse withstand voltage
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM225/30