Specifications

hide show
Range
Clipsal - Series 4
Product or component type
residual current breaker with overcurrent protection (RCBO)
Product brand
Clipsal
Device application
distribution
Poles description
1P + N
Neutral position
left
Number of protected poles
1
[In] rated current
20 A
Network type
AC
Trip unit technology
thermal-magnetic
Curve code
C
Earth-leakage sensitivity
30 mA
Earth-leakage protection class
type A
Breaking capacity
6000 A Icn at 240 V AC 50 Hz conforming to EN/IEC 61009-1
Quality labels
RCM
Device location in system
outgoer
Network frequency
50 Hz
[Ue] rated operational voltage
240 V AC 50 Hz
Magnetic tripping limit
5...10 x In
Maximum tripping time
40 s
Limitation class
3 conforming to EN/IEC 61009-1
[Ui] rated insulation voltage
400 V
[Uimp] rated impulse withstand voltage
4 kV
Contact position indicator
yes
Control type
toggle
Local signalling
ON/OFF indication
Mounting mode
clip-on
Mounting support
DIN rail
Connection pitch
9 mm pitches
2
Height
97 mm
Width
18 mm
Depth
72 mm
Net weight
136 g
Mechanical durability
20000 cycles
Electrical durability
10000 cycles
Locking options description
  • sealable
  • padlocking device
    • Connections - terminals
    • tunnel type terminal - 1...16 mm² - flexible
    • tunnel type terminal - 1 x 10 mm² - flexible with ferrule
      • Wire stripping length
      • 13 mm for top connection
      • 11 mm for bottom connection
        • Tightening torque
          2-2 N.m top or bottom
          Earth-leakage protection
          integrated
          Market segment
          residential
          Standards
        • AS/NZS 61009.1
        • IEC 61009-1
          • IP degree of protection
          • IP20 conforming to IEC 60529
          • IP40 (modular enclosure) conforming to IEC 60529
            • Pollution degree
              3
              Overvoltage category
              III conforming to IEC 60364
              Electromagnetic compatibility
              8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
              Tropicalisation
              2 conforming to IEC 60068-1
              Ambient air temperature for operation
              -25-60 °C
              Ambient air temperature for storage
              -25-70 °C
              EU RoHS Directive
              Under investigation

              Documents & downloads

              hide show
              Filter items
              • All

              • Product Brochures

              • CAD Files and Packs

              • Technical Data Catalogues

              • Installation Instruction

              • Product Environmental

              • Operating Manuals

              • Specifications

              • Certificates (MSDS)

              • Corporate Marketing

              Frequently Asked Questions

              hide show

              What are the dimensions for the 4RCBE220/30S?

              The dimensions for the 4RCBE220/30S are - L93mm x D72mm x W18mm

              For further information , visit link below:-
              https://www.clipsal.com/Trade/search-results?q=4RCBE220/30S
               

              What does the yellow warning label adjacent the bottom neutral terminal indicate on a RCBE220/30S?

              Please refer to the attached literature for details.

              Is the part 4RCBE220/30S still available?

              Yes

              Do you have a 10A RCBO double pole and 1 module wide?

              Yes, we do have a 10A RCBO double pole that is 1 module wide. The part number is RCBE210/30S.

              Replacement for the 4RCBE110/10

              This part has been replaced with 4RCBE210/30S

              What is the part number for a 20A, 10mA RCB?

               The part number is 4RCBE220/10s

              What is part number for 20amp 10ma single module RCD/MCB?

              The part number for 20amp 10ma single module RCD/MCB is a 4RCBE220/10S.

              What are the codes for a 20A 10mA 1pole rcbo ?

              4rcbe220/10
              or
              A9D40620

              Do 4RCBE220/10S suit Schneider chassis?

              4RCBE216/10S does NOT fit onto a standard Chassis.
              reason is the two small terminal screws for active and neutral do not match  the tee off spacing 

              What is the alternative to the 4RCBE210/30?

              Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

              is the 4RCBE210/10S and similar a Type 1 RCBO used for hospital applications ?

              In hospital applications, Type1 RCBO must be used.

              4RCBE210/10S is a type 1 RCBO. However it is different to the one used in medilec panels.

              Is there an alternate part number for 4RCBE120/30H, Heinemann CF1 MCB replacement?

              Unfortunately not. We do not have a replacement for 4RCBE120/30H. None of Clipsal's current range of RCBO's can be used as a replacement for Heinemann CF1 MCB.
               

              Whats the part number for a 10mA, 20A RCD MCB?

              The part name is 4RCBE220/10S

              Looking for a 10mA 20A RCBO.

               Part code is 4RCBE220/10

              Do Clipsal have a 20a single module RCBE @ 10ma suited for hospital use ?

               
               
               
               
              Yes we do , In this case it would be the 4RCBE220/10S.
              To be approved for use in hospitals the RCBO must be approved as "Type 1" (ie: 10mA sensitivity, switch both Neutral and Active, and trip in <40ms)
              The below range of Slimline RCBO's are rated as Type 1 and therefore compatible


              For more information on Clipsal Circuit protection please visit the Clipsal web site on the provided link https://www.clipsal.com/Trade/search-results?q=circuit%20protection

              What bus bar would I use with the RCBE220/30S?

              You would use the RMXPH124.

              Some of the key features are:
              • SLIM Comb busbar is optimised for the SLIM RCBO
              • Resi MAX comb busbar reduces wiring effort, makes wiring easy and installations time efficient
              • Save valuable switchboard space with the SLIM RCBO, a 2 in 1 RCBO system in a thinner module
              For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=RMXPH124

               

              Does 4RCBM220/30 switch both active and neutral?

               4RCBM220/30 will switch both active and neutral.
              For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=4RCBM220/30

              What is the part code for an RCBO 10mAmp 20Amp needed for a school

               The part code is a 4RCBE220/10.

              Can I connect the line to either end of a 4RCBE216/30S?

              Yes, the 4RCBE216/30S is top and bottom line and load compatible for ease of installation.

              Some of the key features are:
              • Unique new white finish for a fresh modern look
              • Base module = 18 mm wide, compact standardised and consistent module dimensions
              • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
              • Cable automatically guided to the correct position: terminals with guard
              • Fast closure

              For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBE216/30S

              What is the part number for a 20A RCBO double pole?

              The part number for a 20ARCBO double pole is 4RCBE220/10.

              What is the replacement for part number 4RCBM220G30?

              4RCBM220SI30 is the replacement for part number 4RCBM220G30. 4RCBM220SI30 is RCD/MCB, 2 module, 2 Pole, 20A, 30mA, 10KA, C-Curve SI-type, super immune,  A-type, surge current protected to 3000 A 8/20ms.
              For further information, please refer to the below link:
              https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM220SI30
              User-added image
               

              Does the 4RCBE216/30S swittch the neutral as well as the active?

              Yes, the two pole safety feature allows switching of both active and neutral contacts.

              Some of the key features are:
              • Unique new white finish for a fresh modern look
              • Base module = 18 mm wide, compact standardised and consistent module dimensions
              • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
              • Cable automatically guided to the correct position: terminals with guard
              • Fast closure
              For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBE216/30S
               

              What is the part number for replacement 40amp RCBO - 4RCBE140/30?

              The part number for replacement 40amp RCBO - 4RCBE140/30 is - A9D11840

              For further information , visit link below:-
              https://www.schneider-electric.com.au/en/search/+A9D11840
               

              What is the replacement for a 4RCBE110/30?

              The replacement for a 4RCBE110/30 is a A9D61810.
              Some of the key features are:
              • 2 Pole wide
              • 30mA
              • 10A
              • RCBO
              For further informatio please visit www.clipsal.com/Trade/Products/ProductDetail?catno=A9D61810

              What is the part number for a 10amp RCBO , slim type?

              The part number for a 10amp RCBO , slim type is - RCBE210/30S

              For further information , visit link below:-
              https://www.clipsal.com/Trade/search-results?q=RCBE210/30S
              User-added image

              What is the part number for the bus bar to suit the 4RCBE216/30S slim line RCBO ?

              The combination Busbars to suit the slim line RCBO's are the  21501 (12 pole) or 21503 (24 pole)
              For more information on this product range please visit the Clipsal web site on the link provided.
              https://www.clipsal.com/Trade/search-results?q=4rcbe210/30s
               

              What is the replacement part number to the 19584 RCBO?

              The replacement part number to the 19584 RCBO can be the clipsal 4RCBE216/30S

              for more information follow link....
              https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=4RCBE216/30S
              User-added image
              Picture is similar to product, just ratings are different.

              What is the part number for a 2 pole 16amp RCBO that is 1 pole wide?

              The part number for a 2 pole 16amp RCBO that is 1 pole wide is - 4RCBE216/30S

              For further information , visit link below:-
              https://www.clipsal.com/Trade/search-results?q=4RCBE216/30S
              User-added image

              Is there a 2 Pole, 10A, 10mA, RCBE?

              Yes, the part number for a 2 Pole, 10A, 10mA, RCBE is a 4RCBE210/01.

              Is there a alternate part number for 4RCBE116/30H, Heinemann CF1 MCB replacement?

              Unfortunately not. We do not have a replacement for 4RCBE116/30H. None of Clipsal's current range of RCBO's can be used as a replacement for Heinemann CF1 MCB.

              What is the part code for a 40A 2P 10mA RCD

              Use a 4RCBE240/10 RCBO

              What is the Busbar to suit an RCBE216/30S?

              The busbar to suit use to be 4BB4/12, however that part is no longer available. It has been replaced by the schneider model 21501.
               
              Description Ratings
              Rated operational current at 40°C (Ie) 80 A
              Rated conditional short-circuit current of an assembly (Isc) Compatible with the breaking capacity of Schneider E lectric circuit breakers
              Insulation voltage (U i) 440 V
              Rated voltage (U e) 230 V (P4 + N) - 400 V (3Ph + N)
              Rated impulse withstand voltage (U imp) 6 kV
              Degree of protection IP20
              F ire resistance to IE C 69 5-2-1 Self-ext inguishing 9 60°C 30 s
              Colour RAL 7035
              Number of 18 mm modules Comb busbar 1 12

              What is the part number for a single module RCBO 32a 10mA

               
               
               
               
              The part number is 4RCBE232/10S

              What is the part number for a 2 pole 16amp 10kA RCBO?

              The part number for a 2 pole 16amp 10kA RCBO is - 4RCBM216/30

              For further information , visit link below:-
              https://www.clipsal.com/Trade/search-results?q=4RCBM216/30

              User-added image

              What is the part code for a 10A 1phase Socket protected by 10mA RCD

              You can use 56SO310 +56CB4 + 56E3 + 4RCBE210/10

              What is the part number for residential 40A combo RCD & CB?

              The part number for residential 40A combo RCD & CB is a 4RCBM240/30.
              Some of the key features are:
              • Seperate RCD trip flag for easy fault finding
              • new insulated openings for easy busbar installation
              • No need to cut the busbar providing safe and quick fit off
              • Same base module as the 10ka mcb, uniformity in space requirements and installation
              • Same housing and installation features as the mcbs. Safe, easy and fast installation
              • Top and bottom line and load compatible for ease of installation
              • Labelled terminals. Safe, easy and fast installation
              • Top and bottom clip allowing dismounting with comb busbar in place
              • Busbar compatible through an insulated slot
              • Surge current protected to 250a 8/20μs/li>
              • Operating temperature: -5 to 40 deg C
              • Standard type
              • 1-phase
              • 4 kV Rated impulse withstand voltage
              For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBM240/30






               

              Is there an alternative for a 1 module RCD-MCB part number 4RCBE116/30D?

              Yes, however it is larger in size as it requires 4 modules. The replacement part numbers are A9F55116 + A9V02663.

              What is the replacement for a 4EBE220/30?

              The replacement for a 4EBE220/30 is a RCBM220/30.
              Some of the key features are:
              • Seperate RCD trip flag for easy fault finding
              • New insulated openings for easy busbar installation
              • No need to cut the busbar providing safe and quick fit off
              • Top and bottom line load compatible for easy installation
              • Operating temperature: -5 to 40 deg C/li>
              • Mechanical combination Standard-type
              • 4 kV Rated impulse withstand voltage
              For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=RCBM220/30