Enabling NLD function for a ATV61 drive

Issue: Enabling NLD function for a ATV61 drive

Product Line: ATV61

Environment: ALL ATV61 Drives

Cause:  Needs the NLD feature  for the ATV61 drive?

Resolution: The ATV61 has this feature in Menu 1.4 , under the Motor Control Type, select energy Savings ( NLD). The NOLD (no load) function: Reduces the voltage to the motor when selected for variable torque loads. A constant volts/Hz ratio is maintained during acceleration. The output voltage will then automatically adjust to meet the torque requirement of the load

Can you get a cover only for a SC2025XA outlet?

Yes, however it only made as a specials item.

For further information please visit https://www.clipsal.com/Trade/search-results?q=sc2025cover

 

What is the part number for the open close auxiliary to suit Acti 9 iLD RCCBs?

The part number for the open close auxiliary to suit Acti 9 iLD RCCBs is - A9A26924

https://www.schneider-electric.com.au/en/search/a9a26924



 

Is there a mounting block that suits the 40?

Yes, there is a mounting block for the 40. The part number is 447.

Some of the key features are:
  • Moulded mounting blocks
  • With metal inserts
  • 3 mounting screw positions
  • suits 40, 40D and switches with 115x48 mm flush plates and 98 mm mounting centres

For further information please visithttps://www.clipsal.com/Trade/Products/ProductDetail?catno=447

 

Compatible I/O units for VAMP 221

Issue
User needs to know which I/O units are compatible with VAMP 221

Product Line
VAMP 221

Environment
I/O units

Resolution
The following I/O units are compatible with VAMP 221. Details for each unit are provided below.

  • VAM 12L accommodates up 10 arc APS_SENSORS, 3 APS_SENSORS have dedicated trip outputs
  • VAM 12LD accommodates up 10 arc APS_SENSORS, 3 APS_SENSORS have dedicated trip outputs
  • VAM 10L accommodates up 10 arc APS_SENSORS
  • VAM 10LD accommodates up 10 arc APS_SENSORS
  • VAM 3L accommodates up to 3 fiber loops
  • VAM 3LX accommodates up to 3 fiber loops with sensitivity adjustment
  • VAM 4C accommodates up to 3 current transformers
  • VAM 4CD accommodates up to 3 current transformers

Is old style A25A still available?

No. Part number A25A is no longer available in Old style.

Does the old Auxiliary contact of old contactor suit the new LC1D contactors?

Old Auxiliary contact for contactors won't go with new contactors but new auxiliary contacts will go with old contactos.

What replacement parts for the 230DRAVL combine meter/ switchboard are avaliable?

For a list of replacement parts see table below:
 
Description Part Number
Bracket only for temporary power service pole (excludes pipe).
Note: a pipe and bracket are required for temporary power service.
230PBV
Spare U-bolt and hex nuts for 230PBV 230UB
Spare doors to suit 230DRAVL 230DRAVAD
Spare neutral and earth bar assembly SP-6500138
Sliding bracket for temporary power leads SP-6330135

For further information please visit https://www.clipsal.com/Trade/search-results?q=230DRAV
or see PDF attached.
 

 

What is the replacement for the old Video distribution Unit?

The alternative for the old Video distribution is a 3105VDU38IR.
 

Can the LED kits for the 56 Series be mounted to the old range

No, there is no support shaft on the old products

Can I still buy flaps to suit the old style 56 Series PDL 56SO432

No old style flaps are not available

What is the part number for an old style cover PDL692WH

The part number is PDLO692CWH

What is the old version of Clipsal C2025VC2 plates

Part number C2025VC

Old clipsal product 6600A needed

 Obsolete and deleted. End of life 2000

Does the XY2CH13270 emergency stop rope pull switch comply with Australian standards category 3, safety requirement ?

I understand the category 3 in the Australian standard is equivalent to the ISO 13849-1 standard about Performance Level of a safety chain solution including our emergency stop rope pull switch XY2CH as the inputs. To reach category 3, you need a redundant architecture with a suitable monitoring unit, like the XPSAF safety relay. The XY2CH13270 is able to reach a PLe, category 4 solution with the appropriate monitoring system.
Attached is a file showing the equivalence of the ISO 13850 standard about the emergency stop function, to the Australian standards.
- the typical solutions for the XY2CED emergency stop rope pull switch, applicable to the other switches like XY2CE, XY2CJ and XY2CH. You can find inside a solution in category 3 PLd according to the ISO 13849-1 standard.
Our XY2C* emergency stop rope pull switches are complying to the following standards (they are NISD compliant in the UL standards)
EN/IEC 60204-1 (for the requirements about emergency stop)
EN/IEC 60947-5-1
EN/IEC 60947-5-5
EN/ISO 13850

 

How to transfer cfg.file to Altivar Drive using the multi-loader ?

Issue:
How to transfer cfg.file to Altivar Drive using the multi-loader ?

Product Line:
VW3A8121

Environment:
All

Cause:
Needs to transfer a CFG file to Altivar Drive

Resolution:

Procedure is as follows:

>put the cfg file (ex.: test.cfg) to Multiloader's SD card

>connect Multiloader to ATV Drive

>turn-ON the multiloader

.wait...
..on the display:
Main Menu
Action

>press  [ENT]

..on the display:
Action Config
MLD->Device

>press [ENT]

.wait...
..on the display:
MLD -> Device
Folder or File name (1st file or folder will be displayed on this line)

>use arrows v^ to navigate and find the correct folder
>use [ENT] to enter the folder
>use v^ to select the correct cfg file (ex.: test.cfg)

..on the display:
MLD->Device
test.cfg

>press [ENT]

.wait...
..on the display:
test.cfg
>>>>>     (progress bar is growing left)

..on the display:
Store config
Successful

>press [ENT]

..on the display:
Action Config
MLD->Device

>turn-Off the Multiloader

>disconnect Multiloader from ATV Drive

What are the codes for the old version PDL 692MBBZ, 692MSS and 692MPB cover plates?

Part numbers for the old version cover plates are PDLO692MBBZ, PDLO692MSS and PDLO692MPB

Are there any busbar/fuse carriers available for the OLD Gael boards

 There are no busbars or fuses carriers available now for the old Gael boards

What is the replacement part number for the old Telemec LC1FG43 Contactor?

The Part number is the LC1F185 185 Amp TeSys F.

Can you use the old down rods with the new fans?

No unfortunately they aren't compatible. the new fans need the new down rods.

Was your old dimmer 32E450LM a trailing edge or leading edge?

The dimmer 32E450LM was a leading edge dimmer.

What is the new part number for old 32538?

New part number for old NS Breaker, is a - LV432538
For more information see data sheet.....https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432538....

Can I purchase an old style 56 Series socket cover

Yes, the part number is PDL 56SOCVRLEGY

What is the replacement cover for the old style range switch PDL range

PDL 679C

Can I use the latest Control System IP Utility V1.5.0.3 programming the old CNI (5500CN)?

No, Control System IP Utility V1.5.0.3 doesn't support the old CNI (5500CN), it can only be used programming the CN2 (5500CN2).
Program the old CNI (5500CN) requires the old Control System IP Utility V1.3 or Lantronix DeviceInstaller V4.4.0.2.
 

What is the modern alternative for an RM2JA111M old range measurement relay?

Parts reference RM35JA32MW is the nearest alternative but not an exact equivalent for the RM2JA1117M.
 

What is a replacement for an old PDL WRC335?

The Wilco WMS332CO is the closest product available for the old PDL WRC335.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=WMS332CO


What is the difference between the old SCP and new SCP (System Control Panel)?

The old SCP (865-1050) is used to configure the original XW and SW inverter charge units, with the addition of newer features implemented by the updated firmware of these units, though the old SCP can only be firmware
 upgraded so far to the point where it could not configure a good deal of the new features.
The new SCP (865-1050-01) has all the same programming capabilities as the old SCP but also includes the ability to program the new features included with the updated firmware found on the XW and SW inverter charge units.

It is advised that if you have the old model SCP, to replace it with the new SCP.

old style 600 series cover in MBBZ

You will need to contact customer care to check availability but you generally just need to insert an 'O' into the part code to signify the Old style.

 PDLO695MBBZ not avail
PDLO692MBBZ is avail
PDLO691MBBZ is avail
PDL694MBBZ is avail

What is the replacement part number for the old Mistral wall ex-fan - BVWE250?

The replacement part number for the old Mistral wall ex-fan - BVWE250 is - 7108A & 2 x 7100WP

For further information visit the link below:-
https://www.clipsal.com/Trade/search-results?q=7108A
https://www.clipsal.com/Trade/search-results?q=7100WP
User-added image
User-added image

What is part number for 2 gang Double pole GPO with Neon old style?

The part number for 2 gang  Double pole GPO with Neon old style is a - 25DN

For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=25DN

User-added image

What is the replacement for an old RC310DPM?

The replacement for an old RC310DPM would be the WMC310D.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=WMC310D





 

What is the replacement part number for the old DOL motor starter LE1D12N7R12?

The replacement part number for the old DOL motor starter LE1D12N7R12 is - ​LE1D12N7S48

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/LE1D12N7S48


 

Is there any other plates available for conversions of old to new fans for 7100WP

No the 7100WP is the only one available

What is the pivot arm for the old 56 Series DOL Starters

This part has been obsoleted 
 

Can I still purchase Brush Aluminium (BA) plates for Clipsal C2025VS

Plates for the old style vertical double socket is C2025VC-BA

What is the alternate product for the old PDL 98CR270

You can use the PDL 100SA360 which has 360° sensing range

What is the pivot arm to suit the PDL 56 Series DOL starter

Old part code was 56PIVOTARM, this product is no longer available

Looking for a replacement handle for an old moulded case breaker Compact C800N

There are no handles available

What is the surge protection replacement for an old PDL 40kA surge protection

 You can use a 16561

What is the part code for an old Clipsal lamp holder

The code of the lamp holder is 516-we and is still available

L1JCN - C2025V - what is the correct cover plate as old & new

C2025VC-WE (old Style)
C2025VC2-WE (new style

What is the replacement for the old thermal overload relay LR2D3359?

The part number is as follows: LRD365

What is the code for a white cover for pdl695 old style (with Narrow Switches)



PDLO695CWH

Old Merlin Gerin Code 23382 4p 40amp 30ma RCCB is now ?

Code now is A9R51440

What is the alternative replacement for old merlin Gerin code 18073 ?

Code =  A9E18073

Will the new NSX range fit on the same chassis as the old NS range?

Yes it will

What is the part number for a batten holder with a large base?

The part number is 533.

What is the Old GAEL metalwork paint colour?

Mid Grey - Dulux 91558710