Quantcast

Powertag Wiser Energy M 63A 1P+N Bottom

Powertag Wiser Energy M 63A 1P+N Bottom

Powertag Wiser Energy M 63A 1P+N Bottom

Item Number: 4CBEM2B

Retail
$233.81
RRP (Inc. GST)

Product Dimensions

Width icon

Width36 mm

Height icon

Height16.5 mm

Depth icon

Depth43 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Installing and Commissioning a Wiser system

hide show
Filter Items
  • Installing and Commissioning a Wiser system

Specifications

Design

Range

PowerLogic

Product or component type

energy sensor

Product brand

Clipsal

Market segment

  • residential: breaker voltage monitoring
  • residential: overload alarm
    • Product destination

      switchboard

      Sustainable offer status

      Green Premium product

      Physical

      Range compatibility

      Resi MAX & MAX4

      Mounting support

      on circuit breaker

      Mounting mode

      by screws (terminals)

      [Ue] rated operational voltage

      200...240 V AC, +/- 20 %

      Standards

    • IEC 61557-12
    • IEC 61010-1
    • IEC 61010-2-030
    • IEC 61326-1
    • ETSI EN 300 328
      • Height

        16.5 mm

        Width

        36 mm

        Depth

        43 mm

        Net weight

        17.5 g

        Ambient air temperature for operation

        -25-60 °C

        Ambient air temperature for storage

        -40-85 °C

        IP degree of protection

        IP20 conforming to IEC 60529

        IK degree of protection

        IK05

        Relative humidity

        0-95 % at 45-45 °C conforming to IEC 60721-3-3

        Environmental characteristic

      • dustproof class 3S3 conforming to IEC 60721-3-3
      • salt mist class 3C2 conforming to IEC 60721-3-3
      • indoor use
        • REACh Regulation

          Free of Substances of Very High Concern above the threshold

          REACh free of SVHC

          Yes

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP1605012

          Circularity Profile

          ENVEOLI1605012

          Others

          Product name

          PowerTag Wiser M63

          Poles description

          1P + N

          Max current

          63 A

          [Ib] basic current

          10 A

          Starting current

          40 mA

          Saturation current

          130 A

          Product specific application

        • load monitoring
        • circuit monitoring
        • overload alarm
        • energy production monitoring (photovoltaic)
        • energy management
          • Concentrator compatibility

            Wiser IP module

            Type of measurement

          • current
          • voltage
          • active energy
            • Accuracy class

            • class 1 current conforming to IEC 61557-12
            • class 0.5 voltage conforming to IEC 61557-12
            • class 1 active energy conforming to IEC 61557-12
              • Mounting location

                bottom

                Event management

                voltage loss with measured current at voltage loss

                Transmission support medium

                radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4

                Maximum emission power

                10 mW

                Form factor

                monoconnect

                Electrical connection

                connector tooth

                Cable cross section

              • 1 rigid cable 1.5-16 mm²
              • 2 stranded cable 1.5-2.5 mm²
              • 2 rigid cable 1.5-2.5 mm²
              • 1 stranded cable 1.5-16 mm²
                • Network frequency

                • 50 Hz
                • 60 Hz
                  • Maximum power consumption in VA

                    1 VA

                    Quality labels

                    CE

                    Directives

                    2014/53/EU - radio equipment directive

                    Operating altitude

                    0...2000 m

                    Overvoltage category

                    III conforming to IEC 61010-1

                    Measurement category

                    category III conforming to IEC 61010-2-030

                    Pollution degree

                    3

                    Vibration resistance

                    3M4 conforming to IEC 60721-3-3

                    Package 1 Weight

                    0.041 kg

                    Package 1 Height

                    0.5 dm

                    Package 1 width

                    0.6 dm

                    Package 1 Length

                    0.85 dm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • Installation Instruction

                    • End of Life Manual

                    • Product Environmental

                    • Certificates (MSDS)

                    Frequently Asked Questions

                    hide show

                    Is the Centimeter or Eco mind still available?

                    No, however as an alternative we offer the Wiser Communication Module (Concentrator) and PowerTag

                    The part number for the Wiser Communication Module (Concentrator) is a EER72600. The powertag choice will be dependent on the circuit breaker type see attached selection chart.

                    For further information on the Wiser Communication Module (Concentrator) please visit https://www.clipsal.com/products/detail?CatNo=EER72600&tab-document-1=0

                    Wiser Energy IP Module Clipsal

                    Do we have a domestic electricity monitor & where is it listed?

                    Yes we have our Wiser Energy range which utilizes our PowerTag system.
                    For this system to operate you need a Wiser communication module (EER72600) as well as the appropriate PowerTags for your RCD/ Circuit Breakers.

                    More information can be found at https://www.clipsal.com/wiserenergy?backto=%2Fsearch%3Ftype%3Dpage%26q%3Dwiser

                    How can I set my Wiser thermostat for Energy Star guidelines?

                    Issue:
                    How can I set my Wiser thermostat for Energy Star guidelines?
                     
                    Product Line:
                    Wiser Home Management System (version 1 EER series USA model)
                     
                    Environment:
                    EER56000, EER56100, EER58000
                     
                    Cause:
                    Customer would like to make sure his thermostat is set at or better than Energy Star guidelines.  
                     
                    Resolution:
                    To optimize between comfort and energy savings, pre-configured Energy Star templates for both heating and cooling are available through the Wiser portal, www.wiserenergy.com.   From the Thermostats tab of the portal, scroll to the bottom and select "Energy-Saving Templates".

                    How to calculate PowerTag Energy read from Modbus Registers in INT64 format.

                    The energy values are stored in the INT64 bit format.

                    Formula to calculate the Energy for 64bit INT: Energy = ((register 4) * (2^48)) + ((register 3) * (2^32)) + ((register 2) *  (2^16)) + (register 1)

                    What is the impact on energy measurement (kWh) if I mount the PowerTag A9 F63 Power Module upside down?

                    No impact on energy measurement

                    How can I define the communication period of my PowerTag Energy Sensor ?

                    Communication for PowerTag Energy Sensor is set by default to 5 seconds in wireless gateway. But to decrease Wireless traffic it is recommended  to increase this value according to Edge Control system needs (PLC, SCADA…).
                    Example: It is not usefull that the wireles gateway requests metering data for PowerTag Sensor every 5 seconds if SCADA requests only each 30 seconds the wireless gateway.
                    Show More