Quantcast

Max 4 Miniature Circuit Breakers, 2 Pole, 2 Modules, 36mm, 415V, 32A, 10kA

Max 4 Miniature Circuit Breakers, 2 Pole, 2 Modules, 36mm, 415V, 32A, 10kA

Max 4 Miniature Circuit Breakers, 2 Pole, 2 Modules, 36mm, 415V, 32A, 10kA

Item Number: 4CB232/10

Retail
N/A
RRP (Inc. GST)

Product Dimensions

Width icon

Width36 mm

Height icon

Height81 mm

Depth icon

Depth78.5 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Number of poles

2

[In] rated current

32 A

[Ue] rated operational voltage

415 V

Mechanical durability

20000 cycles

Electrical durability

10000 cycles

Connections - terminals

  • screw terminal for 1 cable(s) 0.5-35 mm² rigid
  • screw terminal for 1 cable(s) 0.5-25 mm² flexible
  • screw terminal for 1 cable(s) 0.5-25 mm² flexible with ferrule
    • Wire stripping length

      13 mm

      IP degree of protection

    • IP20 conforming to IEC 60529
    • IP40 (modular enclosure) conforming to IEC 60529
      • Ambient air temperature for operation

        -25-70 °C

        Ambient air temperature for storage

        -40-70 °C

        Standards

        AS/NZS 60898

        Relative humidity

        95-95 % at 55-55 °C

        Height

        81 mm

        Width

        36 mm

        Depth

        78.5 mm

        Net weight

        215 g

        EU RoHS Directive

        Compliant

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        Product out of China RoHS scope. Substance declaration for your information

        Environmental Disclosure

        ENVPEP1304004

        Others

        Curve code

        C

        Number of modules

        2

        Breaking capacity

        10 kA conforming to EN 60898

        Network type

        AC

        Network frequency

        50/60 Hz

        [Ui] rated insulation voltage

        500 V

        Tightening torque

        3.5 N.m

        Tropicalisation

        2 conforming to IEC 60068-1

        Package 1 Weight

        236 g

        Package 1 Height

        76 mm

        Package 1 width

        87 mm

        Package 1 Length

        38 mm
        Show all specifications

        Frequently Asked Questions

        hide show

        What is the part code for a 56 Series with a 32a 10ma RCBO

        Part codes you need a PDL 56CB4  with a 4RCBE232/10

        What is the part number for a 3 pole 32amp D-Curve C/B

        The part number for a 3 pole 32amp D-Curve C/B is a 4CB332D10.

        For further information please visit https://www.clipsal.com/Trade/search-results?q=4CB332D10

        User-added image

        What size cables fit into the 4CB3125/10?

        If the cable is Rigid/ Semi Rigid the 4CB3125/10 breaker will take a cable from 1mm²- 50mm².

        OR

        If the cable is Flexible or Ferrule the 4CB3125/10 breaker will take a cable from 1.5mm²- 35mm².

        What is the replacement for a 4EBE232/10?

        The replacement for a 4EBE232/10 is a 4RCBE232/10.
        Some of the key features are:
        • Unique new white finish for a fresh modern look
        • Base module = 18 mm wide, compact standardised and consistent module dimensions
        • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
        • Cable automatically guided to the correct position: terminals with guard
        • Fast closure
        • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
        • Same housing as AC type MCBs. Uniformity in space requirements and installation
        • Superior, safe and reliable DC breaking per pole
        • Used with marine, telecommunications, solar power, emergency power, battery power
        • Excellent breaking capability for its compact size
        • 36mm Modular Spacing
        • Surge current protected to 250 A at 8/20 uS
        • Operating temperature: -5 to 40 deg C
        • 2 degree of pollution
        • Rated Impulse withstand Voltage is 4kV
        • 40 ms Trip times
        • Standard type
        • 1 phase
        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=4RCBE232/10

         

        What is the part number for the replacement for a 2 pole RCBO , 4EBE232/30?

        The part number for the replacement for a 2 pole RCBO , 4EBE232/30 is - 4RCBM232/32

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=4RCBM232/32
         

        What is the replacement for a 4EBE232/30?

        The replacement for a 4EBE232/30 is a RCBM232/30.
        Some of the key features are:
        • Seperate RCD trip flag for easy fault finding
        • New insulated openings for easy busbar installation
        • No need to cut the busbar providing safe and quick fit off
        • Top and bottom line load compatible for easy installation
        • Operating temperature: -5 to 40 deg C/li>
        • Mechanical combination Standard-type
        • 4 kV Rated impulse withstand voltage
        For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=RCBM232/30

         
        Show More