Number of poles

1

[In] rated current

25 A

[Ue] rated operational voltage

240 V

Mechanical durability

20000 cycles

Electrical durability

10000 cycles

Connections - terminals

  • screw terminal for 1 cable(s) 0.75-16 mm² rigid
  • screw terminal for 1 cable(s) 0.33-10 mm² flexible
  • screw terminal for 1 cable(s) 0.33-10 mm² flexible with ferrule
    • Wire stripping length

      13 mm

      IP degree of protection

    • IP20 conforming to IEC 60529
    • IP40 (modular enclosure) conforming to IEC 60529
      • Ambient air temperature for operation

        -25-70 °C

        Ambient air temperature for storage

        -40-70 °C

        Standards

        AS/NZS 60898

        Relative humidity

        95-95 % at 55-55 °C

        Height

        81 mm

        Width

        18 mm

        Depth

        78.5 mm

        Net weight

        115 g

        Others

        Package 1 Height

        70 mm

        Package 1 Length

        18 mm

        Package 1 Weight

        107.8 g

        Package 1 width

        81 mm

        Curve code

        C

        Number of modules

        1

        Breaking capacity

        6 kA conforming to EN 60898

        Network type

        AC

        Network frequency

        50/60 Hz

        [Ui] rated insulation voltage

        440 V

        Tightening torque

        2 N.m

        Tropicalisation

        2
        Show all specifications

        Frequently Asked Questions

        hide show

        What is the DC operating voltage that can be applied to 4CB150/6?

        The DC operating voltage that can be applied to 4CB150/6 is - 48VDC

        For further information, visit the link below:-
        https://www.clipsal.com/Trade/search-results?q=4CB150/6
        User-added image

        What size cables fit into the 4CB3125/10?

        If the cable is Rigid/ Semi Rigid the 4CB3125/10 breaker will take a cable from 1mm²- 50mm².

        OR

        If the cable is Flexible or Ferrule the 4CB3125/10 breaker will take a cable from 1.5mm²- 35mm².

        Can 4CB220/6DC, 6KA C curve DC breaker be used for AC applications?

        4CB220/6DC is a dedicated D.C, polarized circuit breaker and cannot be used for alternating currents (A.C.) or A.C. application.
        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4CB220/6DC
        User-added image
        Other references: 4CB206/6DC , 4CB210/6DC , 4CB216/6DC , 4CB225/6DC , 4CB232/6DC , 4CB240/6DC

         

        What is the part number of 2 pole, 63A, 6KA, C- curve circuit breaker?

        4CB263/6 is a  2 pole, 63A, 6KA, C- curve circuit breaker.

        Key Features

        • Unique new white finish for a fresh modern look
        • Base module = 18 mm wide. Compact standardised and consistent module dimensions
        • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
        • Cable automatically guided to the correct position: terminals with guard
        • Fast closure
        • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
        • Same housing as AC type MCBs. Uniformity in space requirements and installation
        • Superior, safe and reliable DC breaking per pole
        • Used with marine, telecommunications, solar power, emergency power, battery power
        • Excellent breaking capability for its compact size
        • 36 mm modular spacing

        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4CB263/6


                                                                                                                                                              

        What are the coil voltage codes for the LC1D09 / LC2D09 through LC1D38 / LC2D38 TeSys contactors?

        Issue:
        Coil Voltage suffixes for Tesys D contactors LC*D 09/38

        Product Line:
        IEC Contactors and Starters

        Environment:
        Tesys D contactors

        Cause:
        Selection

        Resolution:
        The following lists the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

        AC Volts ___Code     AC Volts ___Code
        12 ___ J7                   208 ___ LE7
        21 ___ Z7                   220 ___ M7
        24 ___ B7                  230 ___ P7
        32 ___ C7                  240 ___ U7
        36 ___ CC7               277 ___ W7
        42 ___ D7                  380 ___ Q7
        48 ___ E7                   400 ___ V7
        60 ___ EE7                415 ___ N7
        100 ___ K7                440 ___ R7
        110 ___ F7                480 ___ T7
        115 ___ FE7              575 ___ SC7
        120 ___ G7                600 ___ X7
        127 ___ FC7              690 ___ Y7
        200 ___ L7                
                       
        Standard Coil                Low Consumption
        DC Volts ___Code          DC Volts ___Code
        12 ___ JD                           5 ___ AL
        24 ___ BD                         12 ___ JL
        36 ___ CD                         20 ___ ZL
        48 ___ ED                         24 ___ BL
        60 ___ ND                         48 ___ EL
        72 ___ SD                         72 ___ SL
        110 ___ FD                       96 ___ DL
        125 ___ GD                     110 ___ FL
        220 ___ MD                    220 ___ ML
        250 ___ UD                     250 ___ UL
        440 ___ RD