Standard Series, Plug Top, Straight, 2 parAllel PIN, 125V, 10A

White Electric | Standard Series, Plug Top, Straight, 2 parAllel PIN, 125V, 10A

Standard Series, Plug Top, Straight, 2 parAllel PIN, 125V, 10A

Item Number: 492-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Colour

body: white electric

Sustainable offer status

Green Premium product

Physical

[In] rated current

10 A

[Ue] rated operational voltage

110 V 50/60 Hz conforming to EN 60309-2

Connections - terminals

screw terminal

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP1605009

Material

Material

plastic

Others

Package 1 Bare Product Quantity

1

Voltage colour

blue

Plug, socket, control station shape

straight

Duration

6 h

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

4.4 cm

Package 1 Width

7 cm

Package 1 Length

10 cm

Package 1 Weight

30 g
Show all specifications

Frequently Asked Questions

hide show

How to Converting Old C-Bus v2 to C-Bus Toolkit

- Download Toolkit 1.9.3 - this is the last version that had the 'Import' feature.(Require 32Bit Window OS)

- Install C-Bus V2 or create a Projects directory structure as per screen shot:

 C:\Clipsal\CBUSV2\PROJECTS\"project folder name"

1

- Example of Files that will be required in that Project Directory:

 5

- Open Toolkit v 1.9.3 and click Projects and select 'Import Projects from V2...."

3

- Select the project from the column on the left and click OK

 4

 - You should then receive the below message once converted:

5

 - Advice that you should then export as .cbz then import the .cbz into the latest toolkit as an upgrade might be required.


 

What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

Product Line:
Circuit Breakers

Resolution:
Shunt Trip, Second Shunt Trip, and Shunt Close
Voltage 50/60 HzT-, W-, & Y-Frame
Fixed
T-Frame
Drawout
W- & Y-Frame
Drawout
12 dcS47359S33809S48490
24–30 ac/dcS47360S33810S48491
48–60 ac/dcS47361S33811S48492
100–130 ac/dcS47362S33812S48493
200–240 ac/dcS47363S33813S48494
277 acS47364S33814S48495
380–480 acS47365S33815S48496

See instruction bulletin, 48049-237-03

For VA consumption

What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Issue:  
What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

Product Line:
Masterpact NT NW

Resolution:
Shunt trip: operating threshold is 0.7x to 1.1x Vn (nominal voltage)
Shunt close: operating threshold is 0.85x to 1.1x Vn
Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
 
Voltage (V) at 50/60 HzT-, W-, & Y-Frame FixedT-Frame DrawoutW- & Y-Frame Drawout
12 DCS47359S33809S48490
24-30 AC/DCS47360S33810S48491
48-60 AC/DCS47361S33811S48492
100-130 AC/DCS47362S33812S48493
200-240 AC/DCS47363S33813S48494
277 ACS47364S33814S48495
380-480 ACS47365S33815S48496

MX operating time at Vn:  50 ms ±10 (NW and NT)
XF operating time at Vn:  
70 ms ±10 (NW ≤ 4000 A)
80 ms ±10 (NW > 4000 A)
55 ms (NT)

NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for a minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200 ms.

Why is my Wiser Air (North America model) account showing unable to reach device? - Wiser Air EOL (North America models) -

Product Line:
Wiser Air (North America model)
Resolution:
End of Life Announcement for Wiser Air Thermostat
 
Schneider Electric announces the end-of-life and end-of-support in North America for the Wiser Air Thermostat and the decommissioning of the Wiser Air Thermostat mobile and web applications.
 
The Schneider Electric Support Team will continue to help customers still using the product until servers are decommissioned.
 
 
 
 
Wiser Air models
 
 
Eligible Wiser Air Thermostat models:
 
  • WISERAIR10BLKU
  • WISERAIR10BLKUS
  • WISERAIR10WHTUS
  • WISERAIR10BLKCA
  • WISERAIR10WHTCA

Wiser Air can only be controlled via the thermostat if the application servers are down or unable to access the Wiser Air account.

 

How to backup and restore Dalibuilding database?

Require SQL Server Management Studio backup and Attach Databases in Management Studio

To Backup > Right click on the database and select Task > Backup

Select Location and Ok .BAK file

 

to Restore, Right click > Restore Database

Choose Device > click the three dot

Then Click Add > 

 

Select the backup .BAK then Ok > Ok then OK

What's the difference between a regular Home member, an Administrator and the Homeowner?

The Homeowner has access to all functions. Administrator has access to all functions except the ability to transfer the homeowner rights, delete the home and granting administrator rights to other members. A common member only has access to operate devices, receive notifications (alarm, moment/automation trigger, device added/removed and invite) from a home, configure device settings and schedules.

Show More