adaptor bayonet cap

BC Lampholder Adaptor

Catalogue Number: 466
adaptor bayonet cap
Retail
$16.60
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Black 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
BC lamp holder adaptor
Colour tint
white electric
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
16 g
Package 1 Height
40 mm
Package 1 width
22 mm
Package 1 Length
27 mm
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

Frequently Asked Questions

hide show

What is the explanation of the Parameter FLC1 in TeSys T.

FLC1 is the parameter to enter the Motor nominal current in TeSys T. In this parameter, the Motor nominal current is entered as a percentage of the rated value of the TeSys T. 

Example:
 
For TeSys T of range 8Amps (LTMR08) and a motor of 2 Amps nominal current, you have to set the FLC1 value to 25% because the Motor nominal current is 25% of the full load current of TeSys T Module (LTMR08).
 
This means that the current in register 466 (value of current in percent) take the value of 100% when you reach 25% of the current of the TeSys T Module rated current value.

Why is my Conext CL showing an alarm code: 4661 & 4662 ( PV1&PV2 SPD Service Alarm)

Issue: 
Customer is calling to confirm alarm codes: 4661 & 4662 ( PV1&PV2 SPD Service Alarm) 

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Cause:
PV1 or PV2 input SPD reached End of Life
SPD remote control wiring issue

Resolution: 
Check the SPD and replace EOL cartridges if required
Check SPD remote wiring 

Clipsal 426 is discontinued, what is a suitable replacement

the 426 is desigend to fit a junction box - an alternative would be to use the PDL570R (surface socket) + PDL530 (mounting block)

Is the socket available for the Clipsal appliance plugs 464 & 465?

No, we don't have an offer for the socket

What are the processor and clock speeds of the current Quantum CPUs?

The following chart lists all current Quantum CPUs and their processor clock speeds:

CPU Model
Processor / clock speed
140CPU11302
186 / 20 MHz
140CPU11303
186 / 20 MHz
140CPU43412A
486 / 66 MHz
140CPU53414B
586 / 133 MHz
140CPU31110
486 / 66 MHz
140CPU65150
586 / 166 MHz
140CPU65160
586 / 266 MHz
140CPU67160
586 / 266 MHz

Where to download the Zelio Soft2 version 4.6 from??

How do I upgrade Vijeo Designer 4.6 to Vijeo Designer 6.2?

You will have to upgrade from Vijeo Designer 4.6 to Vijeo Designer 6.1 Then you can upgrade from 6.1 to 6.2.

What is the replacement for ATV31H055M2 VSD?

 The replacement for ATV31H055M2 is  ATV312H055M2

ATV312H055M2 
variable speed drive ATV312 - 0.55kW - 1.4kVA - 46W - 200..240 V- 1-phase supply

For more information see;=https://www.schneider-electric.com.au/en/search/ATV312H055M2?category=product

Do you sell the 486 RCD tester leads as a spare part?

No, unfortunately this tester is no longer available. Therefore spare parts have also been discontinued.

This tester has been replaced with the all in one 493 Spark-E-Mate.

Some of the key features are:

  • Earth continuity
  • Insulation resistance
  • Polarity
  • Circuit connections 
  • fault loop impedance
  • RCD Trip
  • digital LCD dispay
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=493

Why is my Conext CL showing an alarm code: 4660 (AC Mod OT Wrn Service Alarm)

Issue: 
Customer is calling to confirm an alarm code: 4660 (AC Mod OT Wrn Service Alarm)

Product Line: 
Conext CL 18000NA Conext CL 25000NA Conext CL 20000E Conext CL 25000E

Environment:  
On site troubleshooting

Resolution: 
Check cooling (fans, air inlet, air outlet, installation conditions)
AC module sensor has crossed nominal operating range and the inverter starts to derate output power
If nothing abnormal, call local Technical Support for assistance in troubleshooting and starting an RMA

Cause:
High external temp, cooling problem, internal circuit detection issue

How can you get Altivar ATV16 to hold in place without using mechanical holding brake?

Issue: How can you get Altivar ATV16 to hold motor in place without using mechanical holding brake?
 
Product Line: ATV16
 
Environment: All
 
Cause: N/A
 
Resolution: The ATV16 Can`t produce 100% torque at zero speed so the drive will not work in this type application.


 

Is it possible to get replacement blades for a 6220-0?

Yes it is.
The part number is SP-254-16709.
This is done as a special and will take between 4-6 weeks for delivery.

For more information, visit the website at www.clipsal.com/Trade/search-results and click on the link to view a brochure.