spacer mounting pvc std ptn
Mounting Spacer
spacer mounting pvc std ptn
Mounting Spacer

Mounting Flange, ShAllow Mount

Catalogue Number: 449AS
spacer mounting pvc std ptn
Mounting Spacer
spacer mounting pvc std ptn
Mounting Spacer
Colour: White Electric
Colour: Per UOM Std.
  • Beige 1 PCE
  • Black 1 PCE
  • Cream 1 PCE
  • Red 1 PCE
  • White Electric 1 PCE

Specifications

hide show
Product brand
Clipsal
Product or component type
flange mounting kit
Shape
rectangular
Fixing center
84 mm
Depth
10 mm
Length
119 mm
Width
74 mm
Material
PVC (polyvinyl chloride)
REACh free of SVHC
Yes
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Specifications

  • Case Studies

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is mounting block to suit P2031VH?

Part no P2031VH will fit on either 449A or 449ASD mounting block

Do you do a 449ASD to suit the Slimline Series?

Yes the part number is 449BSD.

What is the part number for an insulating back plate for a 449A?

The part number for an insulating back plate for a 449A is 449AP.

Some of the key features are:
  • Provides 10 mm extra depth for additional cabling
  • 4 mounting screw positions
  • Mounting direction: Horizontal and vertical

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449AP



 

what is the part no for a shallow mounting block like the 449A?

the part no is 449ASD
https://www.clipsal.com/Trade/Products/ProductDetail?catno=449ASDUser-added image

Do the 448 and 449A, both suit the Prestige range?

Yes, they do suit the Prestige Range.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=448 
https://www.clipsal.com/Trade/Products/ProductDetail?catno=449A 



 

Is the 449A available in transparent?

Yes, the 449A is available in transparent. The part number is 449A-TR.

Some of the key features are:
  • Moulded surface mounting blocks
  • With metal inserts
  • 6 mounting screw positions
  • Mounting direction:Horizontal and vertical
  • 12 combined cable/conduit cut-outs
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449A

 

What are the dimensions of the 449A mounting block?

The 449A has the dimensions 122mm long, 78mm wide, 32mm deep.

Some of the key features are:
  • Moulded surface mounting blocks
  • With metal inserts
  • To suit all standard size accessories

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449A

Will a 2000 series plate mount on a 449ASD mounting block?

Yes, a 2000 series plate will mount on a 449ASD mounting block.

Some of the key features are:
  • Moulded mounting flanges
  • standard size
  • Deep mounting
  • With metal inserts
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449ASD

 

What glue is suitable for use with a 449A mounting box?

You can use any glue that is suitable for use with PVC.

What is part no for mounting block to suit A31VX

Part no A31VX will fit onto any standard wall box eg 449a

- Does the 30USBCM fit into 2025XA and C2025XA

Yes it will fit into 2025XA / C2025XA, with the following mounting hardware only: 154, 154RM, 154/1, 155NAR, 155VNAR, 155PRM, 156/2, 157, 164, 449A. Will not fit SC2025XA / 25XA. ( Also please note that it will need to be placed into plate in vertical configuration)
For more information on the 30USBCM please visit the Clipsal web site or click  link provided .https://www.clipsal.com/Trade/search-results?q=30usbcm

What is the mounting block to suit the PDL 800 Series

The 449C is deep (34mm) and the 449CSD is shallow (16mm).
Both can be fitted to the 449BAP to create a double insulated mounting block, this will add 9mm to the depth..

Is there a mounting block for a A25A?

No, unfortunately there is no mounting block for a A25A.

However the A15A can be mounted on a mounting block eg. 449A

Do we have a mounting block suitable for Iconic?

Using the Clipsal 449A there will be slight overhang on the ends for Iconic range. It is recommended to use the 449C for a better solution. 

 

What is the code for a C125N lockout device?

The code is the 44936

Is 449B, mounting block available in black?

Unfortunately not, 449B is not available in black. It is only available in White Electric.
For further information, please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=449B

Can you use a 2449ASD with a 2000MFV800?

Yes, they can be used together but you may need longer screws.

What is the part number for a shallow mounting block to suit slimline?

449BSD 16mm mounting block to suit slimline

What is the mounting accessory for the PDL 895A?

Any standard flush box (144MT) or standard mounting clip or bracket is suitable as the 800 series has standard mounting hole dimensions, or the 449CSD shallow (16mm) or 449C deep (34mm) mounting blocks.

Is there a mounting block to suit the Saturn range?

The 449BSD is the part number for a mounting block specifically designed for Slimline but will suit Saturn ranges.

Please see below brochure for entire new range.
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000262.pdf

Is there a part number for a mounting block for Saturn , standard size

449B-WE. or 449BSD ,Only available in white - These are designed to suit the Slimline series but will accommodate the Saturn range as they have similar recess mount requirements.

For more information please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=449b

What is fault code CLF on an ATS48?

Issue:
ATS48 displays code CLF

Product Line:
Altistart 48

Environment:
All models

Cause:
CLF error in the display.

Resolution:
The ATS48 monitors the control power on CL1/CL2.  If the voltage experiences a sag below 44Vac for more than 200msec, but returns quickly enough for the internal power supply to ride through, then the ATS48 will fault CLF.

Verify the presence and stability of power on CL1/CL2.

ATS48 internal causes may include:
Control terminal not seated properly
Wiring from control board to power board J4 plug
Defective/failed power board

What is the part number of the mounting flange to suit Modena M8025L, auto-switched double socket outlet?

449CSD is the part number of the mounting flange suitable for M8025L.

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449CSD

what is the Depth of the 449BSD ?

The 449BSD is 16mm Deep.
For more information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=449B

I need information about dissipation (power loss) for line choke VZ1L530U045T. Do you have any data about harmonic level during start/stop sequence w...

Goals and Symptoms

I need information about dissipation (power loss) for line choke VZ1L530U045T. Do you have any data about harmonic level during start/stop sequence with and without line choke. When we use line choke with ATS, and have line and bypass contactor (connected to ATS !), is it possible to bypass line choke at END OF RAMP (then it will be used just during start/stop sequence), or it must be connected during whole motor run time? Other way of question: how to install line choke: 1. after line contactor and supply of bypass contactor - outgoing side of choke connected to ATS, or 2. between circuitbreaker and line contactor? Customer wants to implement variant 1. Is it recommendable? System will be implemented on ship, 440V, 60Hz, with generator 1140kW, 1460A. Motor is 285kW, 443A. Softstarter will be ATS48C59Y, and will not be disconnected after starting sequence.

Facts and Changes

ATS and line choke

Causes and Fixes

Line inductance are recommended if there are a few ATS on a same supply to avoid mutual perturbations due to voltage harmonics.
Also It may limit the transient overvoltage if the supply is perturbed.


ATS48 generates significant current harmonics uniquely during the starting and stopping phase, in steady state (when the thyristors are full conducting) they are negligible THD<2% and null with the starter is bypassed.
The harmonics level is difficult to calculate accuratly because it's depending on the impedance of the all installation and it varies with the motor load (power factor is not constant).
The following value are average for a general case:
The maximum values are
Row 5 : 20% of fundamental
Row 7 : 14% of fundamental
Row 11 : 9% of fundamental
Row 13 : 6.7% of fundamental
Other rows are negligible.

Row 3 : less than 10% can appears with a low power factor (no load or at bigenning of starting).

Power loss for VZ1L530U045T = 531 Watts

You can use line choke during start/stop sequence and bypassed after that, connect between the ATS and the line contactor just after the wiring for bypass line ( ie in the user's manual put the choke in place of rapid fuses )


Legacy KB System (APS) Data: RESL159815 V1.0, Originally authored by on , Last Edited by on
Related ranges: Altistart 48