MASTER YOUR CASTLE with your new build or reno project
Enter competition
socket flush 3pin 10a 250v

415

UnSwitched Sockets, Flush Mount, Power Outlet Single 250V 10A - 3 pin

socket flush 3pin 10a 250v
Colour: White Electric
Colour: Per UOM Std.
  • Brown 1 PCE
  • Grey 1 PCE
  • White Electric 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
  • Single outlet
  • Escutcheon Plate Socket
  • 3 pins
  • Straight Angle of Plug
  • Terminals accommodate 3 x 2.5 sq mm cables & earth contact terminal accommodates 4 x 4 sq mm cables
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Device mounting
flush
Fixing mode
by screws
Material
PVC (polyvinyl chloride)
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
27 mm
Length
94 mm
Width
42 mm
Fixing center
84 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Environmental Disclosure
      ENVPEP130201EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the replacement for the LC1D1810 at 415 volt?

      The replacement for the LC1D1810 at 415 volt is the LC1D18N7.....comes with 1 N/O and 1 N/C auxiliary already fitted as standard. 
       

      Is part no 415 still available

      Part no 415 is still available

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=415

      User-added image

      What is the alternate to a PDL 58 flush socket?

      The PDL 58 is obsolete, there is no direct replacement.

      Motor power in kW of a LE1M35U705

      0.25 kW at 415 V AC 50/60 Hz
      0.25 kW at 380...400 V AC 50/60 Hz
      0.12 kW at 240 V AC 50/60 Hz
      0.12 kW at 220...230 V AC 50/60 Hz
       

      The LC1D4011N7 is a discontinued part - what is the alternative?

      LC1D4011N7
      Reason for substitution:  end of life
      Substitution date:  30/12/2009
       
      This product is replaced by:
      LC1D40AN7   -   TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil

      Product enquiries for Generator website

      If you have a product enquire on the Generator Reward Website you can contact the Accumulate Fulfilment Team 1300 135 415 If the customer is still not receiving enough information ESCALATE to Stav Angelopoulos

      I ordered a product from the Generator Rewards website, and hasn’t been delivered

      If you have purchased a product online, please make sure you provide your confirmation number then you can contact the Accumulate Fulfilment Team on 1300 135 415 or email generator@accumulate.com.au If the customer is still not receiving enough information ESCALATE to Stav Angelopoulos

      Are contactors LC1D38.. and LC1D40A.. the same size?

      No the two contactor are not the same size, LC1D40A.. is bigger.

      LC1D38N7
      TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 415 V AC 50/60 Hz coil     LC1D40AN7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil

      For more information see:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D38N7;
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D40AN7




       

      What is the 240v Shunt trip MX to fit a iC120 circuit breaker?

      The MX stunt trip 100 VAC to 415 VAC and 110 VDC to 130 VDC to fit the iC120 and the C120 circuit breakers is the A9N26946

      see data sheet .....
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N26946
      User-added image

      What is the replacement for LC1D40004N5 Contactor?

      What are the parts that make up the 29472?

      The two parts that make up the 29472 are:
      29380..........AUTOMATIC CONTROLLER UA 380 TO 415 V......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=29380
      +
      29364......INTERFACE FOR AUTOMATIC CONTROL.......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=29364
      User-added image                 User-added image

      What are the parts that make up the 29472?

      The 2 parts that make up the 29472 are 29380..........AUTOMATIC CONTROLLER UA 380 TO 415 V......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=29380
      +
      29364......INTERFACE FOR AUTOMATIC CONTROL.......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=29364
      User-added image                 User-added image

      I have a fault product that was purchased from the Generator Rewards website

      If you have purchased a product online and there is a fault, please make sure you provide your confirmation number then you can contact the Accumulate Fulfilment Team 1300 135 415 or email generator@accumulate.com.au If the customer is still not receiving enough information ESCALATE to Stav Angelopoulos

      What is the Short Circuit Current Rating for Altistart 48 Range of Soft Starters for 415 Volt (Q series) and 690 volt(Y series).

      The Short Circuit Current Rating (SCCR) for Altistart 48 Range of Soft Starters is as follows: 

      For Q series:
       
      1. SCCR for ATS 48D17x to ATS 48C32x is 50 KA.
       
      2. SCCR for ATS 48C41x to ATS 48M12x is 70 KA.
       
      For Y series:
       
      1. Refer attachment for the Short Circuit Protection Device (Type 1 Coordination).

      What is the voltage and AIC rating on the Multi 9, C45 breakers?

      Issue:
      What is the voltage and AIC rating on the Multi 9, C45 breakers

      Product Line:
      Circuit Breakers

      Environment:
      Applies to C45 circuit breakers only

      Cause:
      Ratings for the C45 circuit breakers

      Resolution:
      For C45 circuit breakers, the 1 pole breaker is rated 5 kA @ 240V, and the 2, 3, 4 pole is rated 5 kA @ 415 V.

      Can the Sepam series 80 voltage inputs be connected directly to a 415 V 4-wire 3-phase LV system (without the use of Voltage transformers)?

      The continuous thermal withstand of the Sepam series 80 voltage inputs is 240V AC, which means that it is not possible to connect the Sepam directly to the network. Furthermore, the Sepam setting tool (SFT2841) does not allow such voltage values to be entered.

      Re-published to revised security level: 17 June 2008 by DRM

      Applies To: Sepam 1000+ (Sepam Series 20 and Sepam Series 40)

      Public

      All content © 1992-2008 Schneider Electric


      Legacy KB System (APS) Data: RESL166655 V2.0, Originally authored by LaVI on 06/18/2008, Last Edited by DaMi on 06/18/2008
      Related ranges: Sepam series 80

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      Are replacement  AC coil available for CAD32 and CAD50 relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      What are the terminal bolt sizes for NSX breakers?

      The bolt sizes are provided on the table below.
       
      NSX Breakers Bolt Size
      NSX100 6MM BOLT
      NSX160 8MM BOLT
      NSX250 8MM BOLT
      NSX400 10MM BOLT
      NSX630 10MM BOLT

      Some other key features on the NSX range are:
      • Nominal current: 16 to 630 A
      • 6 breaking performances from 25to 150 kA at 415 V
      • Voltage rating: up to 690 V
      • 2 physical sizes from 16 to 630 A
      • 3 and 4-pole versions
      • Isolation with positive break indication
      • Large range of electronic and thermal-magnetic protections
      • Earth leakage protection by associated Vigi Module
      • Measure of main electrical values : I, U, P, E, THD, f, CosF
      •  Wide range of common auxiliaries and accessories interchangeable on site
      • Plug and Play Wiring system and communicating accessories
      • Compliance with international standards: IEC 60947-1 and 2, Nema, IEC 68230 for type 2 Tropicalisation, CCC
      • Compliance with specifications of marine classification companies: Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, RINA.
      For further information please see https://www.schneider-electric.com.au/en/product-range/1887-compact-nsx--630a?xtmc=NSX&xtcr=5

      Compact NSX <630A

      What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

      Product Line:
       
      Tesys D line Contactors
       
      Resolution:
       
      The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

      Note 1: LC1D150 contactors are only available with *7 coil codes.
      Note 2: Coil Code ending number represents frequency rating as follows:
      5 = 50 Hertz
      6 = 60 Hertz
      7 = 50/60 Hertz

      AC Volts ___Code                DC Volts ___Code
      24 ___ B5 or B6 or B7          12 ___ Not Avail.        
      42 ___ D5 or D7                   24 ___ BD
      48 ___ E5 or E6 or E7          36 ___ CD
      110 ___ F5 or F6 or F7         48 ___ ED
      115 ___ FE5 or FE7             60 ___ ND
      120 ___ G6 or G7                72 ___ SD
      127 ___ FC5 or FC7            110 ___ FD
      208 ___ L6 or LE7               125 ___ GD
      220 ___ M5 or M6 or M7       220 ___ MD
      230 ___ P5 or P7                 250 ___ UD
      240 ___ U5 or U6 or U7        440 ___ RD
      277 ___ W6 or UE7                
      380 ___ Q5 or Q6 or Q7                
      400 ___ V5 or V7                
      415 ___ N5 or N7                
      440 ___ R5 or R6 or R7                
      480 ___ T6 or T7                
      500 ___ S5 or S7                


       

      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

      Issue:
      Identifying replacement coils for tesys D non-reversing and reversing conactors

      Product Line:
      IEC Contactors and Starters

      Environment:
      Products sold and used in the United States

      Cause:
      Replacement coil is needed

      Resolution:
      DC replacement coils are not available.
      AC Coils are 50/60 hertz for voltages as listed below:

      Volts - Part Number
      12 ____ LXD1J7
      21 ____ LXD1Z7
      24 ____ LXD1B7
      32 ____ LXD1C7
      36 ____ LXD1CC7
      42 ____ LXD1D7
      48 ____ LXD1E7
      60 ____ LXD1EE7
      100 ___ LXD1K7 ( never brought to North America )
      110 ___ LXD1F7
      115 ___ LXD1FE7
      120 ___ LXD1G7
      127 ___ LXD1FC7
      200 ___ LXD1L7
      208 ___ LXD1LE7
      220 ___ LXD1M7
      230 ___ LXD1P7
      240 ___ LXD1U7
      277 ___ LXD1W7
      380 ___ LXD1Q7
      400 ___ LXD1V7
      415 ___ LXD1N7
      440 ___ LXD1R7
      480 ___ LXD1T7
      575 ___ LXD1SC7
      600 ___ LXD1X7
      690 ___ LXD1Y7


      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

      PM8000 Frequently Asked Questions

      Issue
      PM8000 Frequently Asked Questions

      Product Line
      PM8000 series meters
      PM8240
      PM8243
      PM8244

      Environment
      Power Monitoring
      Energy Management
      Specification, Functions and Characteristics, Catalog Number, User Guide, Installation Guide

      Issue
      Find the answer to commonly asked questions about the PM8000 as well as user/installation guides for that meter.

      Resolution

      What are the control power input requirements?
      120 to 300 V DC ± 10%
      50/60 Hz ± 10% : 90 to 415 V ± 10%
      Burden:
          Meter only: 18VA max at 415V AC, 6W at 300V DC
          Fully optioned Meter: 36 VA max at 415V AC, 17W at 300V DC

      What is the rating of the current inputs?
      Nominal 5 A (Class 0.2S) or 1 A (Class 0.5S )
      Measured current: 50 mA to 10 A
      Starting current: 5 mA
      Withstand: 20 A continuous, 50 A @10 sec/hr, 500 @ 1 sec/hr
      Impedance: 0.3 mΩ
      Burden: 0.024 VA at 10 A

      What are the voltage inputs rated at?
      Measured voltage: 57 to 400 V L-N / 100 to 690 V L-L (Wye) or 100 to 600 V L-L (Delta or Wye with unearthed neutral)
      Frequency: 50/60 Hz ± 15%,
      400 Hz ± 10%
      Overload: 600 V L-N or
      1035 V L-L

      What are the options to connect the PM8000 via RS485?
      The PM8000 can be connected via RS485 2 wire. The remote display does not have the option to connect RS485 4 wire as the PM800 does.
      in order to communicate RS485 4-wire, a 2 to 4 wire converter needs to be used.

      What are the maximum number of digital and analog inputs on the PM8000 series?
      27 Digital inputs
      16 Analog inputs

      What is the difference between PM8243 and PM8244?
      PM8243 is DIN rail meter with no display.
      PM8244 is DIN rail meter with remote display. The PM8244 is essentially a PM8243 + remote display (PM89RD96) 

      Documentation:
      For additional specifications for your meter and accessories, view the User Manual on page 155-160 (Document # 7EN02-0336-03).
      PowerLogic PM8000 series User manual: https://www.schneider-electric.us/en/download/document/7EN02-0336/

      For specifications related to installation, such as measured voltage and current ranges, inputs/outputs and control power information, View the installation sheet attached on page 7 (Document # EAV47344-03).
      PowerLogic PM8240 installation guide: https://www.schneider-electric.us/en/download/document/EAV47343/
      PowerLogic PM8243 installation guide: https://www.schneider-electric.us/en/download/document/EAV47344/

      For complete specifications and Catalog number, view PM8000 Technical Datasheet attached.
      PM8000 Technical Datasheet: https://www.schneider-electric.com/en/download/document/PLSED310058EN_Web/

      For information on installing the remote display see the PM89RD96 installation sheet.
      PowerLogic PM89RD96 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47345/

      For information on installing the digital and analog option modules see PM89M2600 & PM89M0024 installation sheet.
      PowerLogic PM89M2600 & PM89M0024 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47347/

      For information on the PM8000 Modbus registers see the PM8000 Modbus Map.
      PM8000 Modbus Map: https://www.schneider-electric.com/en/download/document/PM8000_Modbus_Map/