412 skt surface 3pin 10a 250v

Single Socket Outlet, 250VAC, 10A, 3 Pin, Surface Mount

Catalogue Number: 412
412 skt surface 3pin 10a 250v
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Brown 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Quantity per set
set of 1
Cover type
complete housing
Marking
without marking
Local signalling
without light indicator
Device mounting
surface
Fixing mode
by screws
Material
plastic
Surface finish
glossy
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Network frequency
50 Hz
Depth
28 mm
Diameter
47 mm
Fixing center
35...38 mm
Number of poles
1
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the diameter of part number 412?

      Diameter for part number 412 is 47mm.

      What is the diameter for part number 412?

      The diameter for part number 412 is 47mm.

      What does the 412 suffix mean on the ATV312 drives?

      Issue:
      What does the 412 suffix mean on the ATV312 drives?

      Product Line:
      Altivar 312

      Environment:
      All models

      Cause:
      Cannot find source in the USA

      Resolution:
      Suffix 412 indicates a special ATV312 for solar photovoltaic applications.
      It is not marketed in the USA.  Please contact your OEM for suggested replacements.

      Is part number 413 available in Black?

      Yes part number 413 is available in Black.

      What is the socket to suit the Clipsal 492 492/32 492/32HD

      Socket to suit is 402 series

      402  402/32

      Varlogic R12 controller options

      The only option is the NR12 - part number 52449

      Is there a base compatible with the 342-WE

      No, unfortunately there is no base avaliable for this product as it was designed to mount directly to a ceiling. However there is an adaptor plate avaliable which acts as a base, the part number is 150. Some of its key features are:
      • Suits round junction boxes, surface mounting accessories, 342 Ceiling Switches, 412 Series Surface Sockets and surface mounting products with 46 mm and 38 mm dual mounting centres
      • Mounting Centre: 38mm & 46mm
      • 77 mm Diameter x 3 mm Depth

      For further information please visit https://www.clipsal.com/Trade/342&adaptplaes/
       

      Does the Clipsal 438/2 suit the 492

      The 438/2 does suit the 492. 

      What is the female version of a 492

       The female version is 438/2

      What is the part number for a 413 surface socket with 4 flat pins?

      The part number is 410.

      What is the nail on base plate for 413 socket outlet??

      Nail on base plate for socket outlet 413 is - 413NP-TR.
      For further information go to:
      https://www.clipsal.com/Trade/search-results?q=413NP
      User-added image

      Does the 413/15 come with a back plate?

      No it doesn't come with a back plate. You will need a 413NP.

      Some of the key features are:
      • For the use of cable ties for cable clamping
      • Not suitable for 414/4P
      • For 410, 413 and 414 products
      • AS3100, AS/NZS3112, AS3109 Certified
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=413NP

      What Does a 452 Diagnostic Code Error indicate?

      A 452 error indicates the meter had an abnormal power cycle. It does not indicate why the meter had the abnormal power cycle.

      For most meters with a single abnormal power cycle (ie. an associated 452 error), it is suggested the customer should continue to monitor it. The customer may choose to upgrade the meter to latest firmware, which has improved diagnostics ability for future investigation.

      For further issues with the 452 Error please contact your local Tech Support.


       

      What are the dimensions of chassis PAN16 ?

      Dimensions =  PAN16   - showing total width as 232 - Height = 432

      What is the difference between the 492 and 492Y ?

      The 492 is designed to suit  2 core 1mm2 ordinary duty flex while the 492Y is designed to suit 0.75mm2 figure 8 flex.
      For more information regarding this and similar products please follow the link provided to the Clipsal website.
      https://www.clipsal.com/Trade/search-results?q=492
      User-added image

      What extension socket suits the 492 plug?

      The extension socket that suits the 492 plug is the 438/2.

      Some of the key features are:
      • Rewireable cord extension socket
      • 2 Parallel pins
      • Suits 1 sq mm Ordinary duty 2 core flexible cord
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/2

       

      What is the part number of the plug to suit surface socket 410 rated to 10A, 500V?

      The part number of the plug to suit surface socket 410 is 439/4. It is rated to 10A, 500V.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=439/4
      User-added image

      What is the Clipsal socket to suit the 439/4 plug

      Clipsal Socket part number - 410

      What is the new F12 fault error on 5.51 Lexium firmware?

      The F12 fault is used to detect whether the motor is connected to the drive power output. ( X9 connector).
      To disable this feature, set the parameter CPHASE to zero.


      Legacy KB System (APS) Data: RESL156769 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Lexium MHD

      What is the elbowed female M12 5 meter long connecting cable

       You can use a XZCP1241L5

      What is the replacement for the LC1D1810 at 415 volt?

      The replacement for the LC1D1810 at 415 volt is the LC1D18N7.....comes with 1 N/O and 1 N/C auxiliary already fitted as standard. 
       

      Is part no 415 still available

      Part no 415 is still available

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=415

      User-added image

      Is the contactor, LC1D09 available for sale without the coil?

      Our LC1D09 to LC1D1506 have to be ordered with a coil voltage. They are not sold less coil. Coil voltages can be found on H12 in the A4 Catalogue.

      What is the CSA file number for the Altivar ATV18 unit?

      Issue: What is the CSA file number for the Altivar ATV18 unit?
       
      Product Line: ATV18
       
      Environment: All
       
      Cause: N/A
       
      Resolution: The CSA number is LR96921.

       

      What are the available condiut entries for a XCKD, XCKP, or XCKT limit switch?

      Issue:
      Identifying characteristics from part numbers

      Product Line:
      XCKD, XCKD, XCKT limit switches
      ZCD, ZCP, ZCT limit switches

      Environment:
      US Product

      Cause:
      It is necessary to have the appropiate conduit entry on a limit switch

      Resolution:
      For a complete limit switch (XC devices) use the following suffixes:
      P16 - ISO M16
      P20 - ISO M20
      G11 - Pg11
      G13 - PG 13.5
      N12 - 1/2" NPT
      F12 - PF 1/2" NPSF
      D44 - Deutch Connector

      For the adapter to fit with a metallic limit switch body (ZCD devices) order the following pieces:
      ZCDEP16 - ISO M16
      ZCDEP20 - ISO M20
      ZCDEG11 - Pg11
      ZCDEG13 - PG 13.5
      ZCDEN12 - 1/2" NPT
      ZCDEF12 - PF 1/2" NPSF

      For the adapter to fit with a plastic limit switch body (ZCP, ZCT devices) order the following pieces:
      ZCPEP16 - ISO M16
      ZCPEP20 - ISO M20
      ZCPEG11 - Pg11
      ZCPEG13 - PG 13.5
      ZCPEN12 - 1/2" NPT
      ZCPEF12 - PF 1/2" NPSF
      ZCPED44 - Deutch Connector

       

      What is the amount of SF6 gas in 24 kV SF Circuit Breaker range.

      In 24 KV SF Circuit Breaker range, the weight of the SF6 gas per pole for different Circuit Breakers is as follows:
       
      1. SF1 Type 1 – 49 grams 
         
      2. SF1 Type 2 – 112 grams
         
      3. SF2 – 240 grams

      Are there any metal cover plates to suit the PDL 617BT2/2?

      Yes, the 612 cover plate suits the PDL 617BT2/2. There are Polished Brass (MPB), Brushed Bronze (MBBZ) and Stainless Steel (MSS).

      Code example (617BT2/2 cover in Polish Brass): PDL 612MPB

      What is the alternate to a PDL 58 flush socket?

      The PDL 58 is obsolete, there is no direct replacement.

      What is the parts breakdown for the 9001K2L38GH13?

      Issue:
      What is the parts breakdown for the 9001K2L38GH13?

      Product Line:
      Operator Interface

      Environment:
      NEMA1,3R, 4,12 IP55 ,IP66

      Cause:
      The component parts are stock

      Resolution:
      • 9001KA1
      • 9001K2L
      • 9001G7
      • 9001KM38

      What is the part number of the nail plate to suit 414, double surface socket?

      414NP-TR is the nail plate for redesigned 414 Series surface sockets.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=414NP

       

      Do you do a 2 pin version of the 413 quick connect?

      No, there is only the 3pin option. The part number is 413QC.

      Some of the key features are:
      • Quick connect in line surface socket
      • 3 pins
      • Round earth pins

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=413QC

       

      What is the part number for the 512 Mb CF card for the smart and Compact iPCs?

      The part number for the 512 Mb Compact Flash card is MPCYN00CFE00N


      Legacy KB System (APS) Data: RESL174338 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Magelis Smart iPC

      Does Schneider Electric offer prefabricated communication cables for Lexium Integrated Drives with industrial cover that have Ethernet communication?

      Schneider does offer pre-made cables with M12 on device side and RJ45 on Ethernet switching port side.
      The model TCSECL1M3M10S2 is a 10 meter long cable.  (see attached data-sheet)

      The connectors that mate to the drive can also be ordered separate using reference number VW3L5K000

      VW3L5K000 is a kit and will come with 2 males connectors M12 4 pin D coded and 1 M12 protective cap ( used to terminate last device in network ), for building your own comunication cables.

      Does the Matrix-UPS have PDU options to provide for other output receptacle needs?

      APC by Schneider Electric used to have several optional PDUs for use with the Matrix-UPS to provide greater flexibility of electrical connections. All PDU options for the Matrix have been discontinued now for over a decade. 


       

      What does 410 at the end of the ATV312 part number mean? Example: ATV312HD11N4410.

      Issue:
       
      Product Line: ATV312
       
      Environment: Part numbers ending in 410
       
      Cause: N/A
       
      Resolution: This is a custom modified version of the ATV312 that is only sold to the customer who had it customized.  
      A standard ATV312 will not work in it's place.  It has to be ordered through the OEM.

      Why is my Conext CL showing an alarm code: 712 & 713 (AC & DC Int Config Fit Service Alarm)

      Issue: 
      Customer is calling to confirm alarm codes: 712 & 713 (AC&DC Int Config Fit Service Alarm)

      Product Line: 
      Conext CL 18000NA Conext CL 25000NA Conext 20000E Conext CL 25000E

      Environment:  
      On site troubleshooting

      Cause:
      Internal configuration on control processor is incorrect (firmware issue)

      Resolution: 
      Reset by turning off DC and AC 
      Upgrade the firmware (2.6.4 or newer)
      Ensure Bootloader (Control Boot) firmware is 2.02.03 or newer

      What is the part code for a 5 meter cable for a XS1M12PAW01D Inductive Proximity Sensor?

      This proximity Sensor requires a 4 pin M12 female connector, the item required will depend on the environment.
      The part code for a 4 pin M12 pre wired female straight connector with PVC flex is XZCPV1141L5 (angled option = XZCPV1241L5)
      The part code for a 4 pin M12 pre wired female straight connector with PUR flex for severe environments is XZCP1141L5
      The part code for a 4 pin M12 pre wired female straight connector for food & beverage applications is XZCPA1141L5 (ANGLED OPTION = XZCPA1164L5)
      2 or 10m options may also be available
      See attached data sheet

      What are the part numbers for SoMachine 4.2 software?

      The part numbers for SoMachine 4.2 software are:

      - SOMNACCZXSPAZZ - SoMachine V4 License Single - Single (1) License with Mandatory registration
      - SOMNACCZXTPAZZ - SoMachine V4 License Team - Team (10) License with Mandatory registration
      - SOMNACCZXEPAZZ - SoMachine V4 License Entity - Entity (100) License with Mandatory registration

      Note: the part numbers for SoMachine 4.3 are the same, the customer will have to specify that he wants version 4.2

      What is the replacement for a 410-2 Single axis Servo positioner?

      Issue: Replacement


      Product Line: 410, Single axis servo positioner


      Environment: None


      Cause: Obsolescence


      Resolution: There is no direct plug-in replacement for the 410 family of single axis servo positioners. Migration to Lexium 32 series drives is the general recommendation. Regardless of whether the 410 drive is used in a standalone application (or) is a remote drop on a PLC, a Lexium 32M drive may be used as replacement. 410-2 being a 10 A drive (continuous current), a LXM32MD30N4  would be an ideal replacement. If the existing motor is deemed compatible, then a resolver option card may be used to commutate the existing motor. If the 410 drive is used as a remote drop on a PLC exchanging data, an Ethernet option module may be used for communication with the PLC over Modbus/TCP.

      Application specific information would be required for a more accurate listing of replacement parts.

       

      What is part number for socket to suit part number 492?

      The part number for socket to suit is a 438/2
      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/2


      User-added image

      What are the causes of the Trip Circuit Fault or CB Control Fault on a SEPAM relay and how may it be cleared?

      Issue
      A trip circuit fault is displayed on the front face of the SEPAM.

      Product Line      
      SEPAM 20, 40, 50, 80

      Environment    
      SEPAM programming

      Cause
      The trip circuit fault on a SEPAM relay is caused by:
      1. Circuit breaker control is enabled but the contacts I11 and I12 are not connected, or are connected incorrectly.
      2. Circuit breaker control is enabled but the contacts I11 and I12 don't transfer within 200ms.
      3. Circuit breaker control is disable but contacts I11 and I12 are assigned to the open and closed status from the breaker.
      Note: If SEPAM 80 Series is being used I11 = I101 and I12 = I102.



      Resolution
      To correct the issue, connect to the relay using SFT2841 then:
      Case 1. Wire the breaker status contacts to I11 and I12 or wire these contacts correctly.
      Case 2. Go to the program logic screen in SFT2841 and reassign I11 and I12 to either customized use if they are being used, or to not used if the contacts are not wired

      Note: Until the fault has been cleared, the relay will continue to show the Trip Circuit Fault on the front display.
      To clear the fault from the front display, do the following:
      1. Press the Alarm button.
      2. Press the Enter key.
      3. Press the Clear button to clear the fault.

      To clear the fault using SFT2841, do the following:
      1. Connect to the relay
      2. Click the Alarm button
      3. Click the Reset button

       

      What is the part numbers for Masterpact NT/NW finger clusters and grease?

      Product Line:
      Circuit Breakers
      Masterpact NT/NW

      Environment:
      Electrical Distribution Equipment

      Resolution:
      Finger Cluster (Each) S33166
      Cluster Grease (12 oz. Tube) S48899
       

      How do you create a SoMachine archive in SoMachine v4.1, 4.2 or 4.3?

      To create a SoMachine archive in SoMachine v4.1 or 4.2 you will have to navigate to SoMachine Central / top-left green button / Save Project as... / Save Archive...

      Proper Formats for Phone Numbers When Using Send Wireless SMS Message Alert Action from Netbotz appliance.

      Issue:

      Proper Formats for Phone Numbers When Using Send Wireless SMS Message Alert Action from Netbotz appliance.

      Product Line:

      NetBotz

      Environment:

      NetBotz version 2 using sms.

      Cause:

      When using the Send SMS Message alert action, the GSM phone number of an alert recipient can be entered in the local format or in international format.

      Resolution:


      Example of local format when a NetBotz appliance is configured to send SMS to a GSM phone number within U.S.:

      5125551212

      Where 512 is a U.S. area code.

      Example of international format when a NetBotz appliance in U.S. is configured to send SMS to a GSM phone number in Australia:

      +614142222222

      Where 61 is the Australia country code, 414 is an area code, and + sign must be used to indicate that it is in international format.

      SMSPE 4.2 and 4.3 Database maintenance

      Issue
      How to perform database maintenance in SMSPE 4.2 and 4.3

      Product Line
      System Manager Software(SMSPE) 4.2 & 4.3

      Environment
      System Manager Software Database Maintenance

      Resolution
      Refer to the attached document and tools for information on database maintenace for SMSPE 4.2 and 4.3.


      SMS 42 - Database Maintenance- Application note.doc

      DBTools_sql2005compatible.zip

      What is the difference between the 140XTS00206 and the 140XTS01206?


      140-XTS-002-xx cable is rated for .5 Amps per point (read as point 5 Amps)
      140-XTS-012-xx cable is rated for 2 Amps per point (read as 2 Amps)

      The following table outlines the different Cablefast cables, their description, and rating:

      140 XTS 002 03 3 foot cable with sub "D" connector Standard power .5 Amps
      140 XTS 012 03 3 foot cable with sub "D" connector High power 2 Amps
      140 XTS 002 06 6 foot cable with sub "D" connector Standard power .5 Amps
      140 XTS 012 06 6 foot cable with sub "D" connector High power 2 Amps
      140 XTS 002 09 9 foot cable with sub "D" connector Standard power .5 Amps
      140 XTS 012 09 9 foot cable with sub "D" connector High power 2 Amps
      140 XTS 002 12 12 foot cable with sub "D" connector Standard power .5 Amps
      140 XTS 012 12 12 foot cable with sub "D" connector High power 2 Amps
      140 XTS 102 06 6 foot cable with pigtail leads High power 2 Amps
      140 XTS 102 15 15 foot cable with pigtail leads High power 2 Amps




      R-82117


      Note: the quantum line will be going obsolete 12/31/2018 and the M580 is the recommended replacement.

      How to connect the XUSL4E curtain with the obsolete pre-wired connectors used in the obsolete XUSLD/B curtain range?

      XUSL4E type 4 safety light curtains and obsolete XUSLD/B light curtains use similar M12 connectors with the same pin number, on each part of the light curtain. Both side of the obsolete cabling accessories need to be changed for the new curtain XUSL4E connection. Attached document precising how to re-use the obsolete XSZBCT/R pre-wired M12 connectors with the new XUSL4E safety curtain.
       

      How to connect the XUSL4E curtain with the obsolete pre-wired connectors used in the obsolete XUSLP equivalent curtain range, for its replacement?

      XUSL4E type 4 safety light curtains and obsolete XUSLP equivalent light curtains use similar M12 connectors with the same pin number, on each part of the light curtain. Both side of the obsolete cabling accessories need to be changed for the new curtain XUSL4E connection. Attached document precising how to re-use the obsolete XSZPCT/R pre-wired M12 connectors with the new XUSL4E safety curtain.

      How long is the cord on the E12-EO RCD/ MCB switched twin socket outlet?

      The cord on the E12 RCD/ MCB switched twin socket outlet is 3 meters long.
      Some of its key features are:
      • Overload protection
      • Amber power available neon
      • 3 metre power cord
      • In-built indicator to indicate whether an RCD or MCB fault has occurred
      • In-built test facility
      • 10 mA trip current
      • Trip Time: < 40ms
      • Operating Temperature Range: -10 to 55 deg C
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=E12
       

      Do you do the 56K1SW220 with a common key?

      Yes, place CK on the end of the part number and the switch will be provided with a 60103 Low and Fletcher Key.

      Some of the key features are:

      • Standard security KSW
      • 107 mm Height x 101 mm Width x 112 mm Depth
      • M250 rating
      • 25 - 10 AWG conductor terminal
      • Less enclosure
      • For Locking In Only The Off Position
      • Dust-resistant, hoseproof and UV resistant
      • Safety in operation
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56K1SW220

       
      Show More