Mech Switch 1/2way 20A/16AX 250V

Clipsal Iconic - Universal Rocker Switch, 1-Way/2-Way, 250V, 20A/16AX

Catalogue Number: 40USM
Mech Switch 1/2way 20A/16AX 250V
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switch
Device application
lighting
Colour tint
vivid white
Quantity per set
set of 20
Device presentation
mechanism
Control type
rocker
Switch function
1-pole 1/2-way
Rated current
20 A
[Ue] rated operational voltage
250 V
Material
plastic
Connections - terminals
screw terminal
Height
23 mm
Width
23 mm
Depth
32 mm
Net weight
0.016 kg
EU RoHS Directive
Compliant
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Frequently Asked Questions

hide show

What is the part number of Iconic LED indicator lights on the mechanism?

40MLEDW is the part number of Iconic LED indicator lights on the mechanism. It can be used on 40M, 40USM and 40MI only to upgrade them to luminous mechanisms. They are warm white LEDs and can be easily wired and set as locator or indicator.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=40MLEDW&mg=341&g=200000362

What parts are required to make a Saturn permanent connection unit (PCU)?

4032VH + 30USM + 38TB

Is part number 30USM Double pole?

No, part number 30USM is not a double pole.

For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM


User-added image

Is the 40CSFM the same as the 40RSM3 without the capacitor?

Yes, the 40CSFM is the same as the 40RSM3 but without the capacitor and pictogram on the front.

Can I get a 30USM with a red dot on the dolly?

Yes, you can get a 30USM with a red dot. The part number is 30USMRD.

Some of the key features are:
  • Reduced visible arcing and crackling
  • Modular 30 mech design suits most Clipsal switch plates
  • With Red Dolly dot
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USMRD


 

Can the 30USM be used for Fluro loads?

Yes , it is rated to 16AX for fluro based loads.

Is a 30USM-WE a normal switch rocker mechanism

30USM-WE = Universal switch mechanism 20/16AX - compared to the 10A only 30M-WE
(see attached 30USM Brochure)

What is the size of the terminal screws in the Clipsal 30USM mech?

Screw B.S M3.5 X 0.6, 5.6mm CH HD IN

 

Is a 16amp mech available marked 'Heat'?

Part number replaced with 30USM mech but marked 'Heat' is not standard.
 

How many dimmers can I fit in to a BSL plate.

You can put a maximum of 3 dimmers in a grid plate.  You will need to order BSL36VH + 3 x 30USM + 3 x whichever dimmer is appropriate for your lighting

Does the WS229 come with push button mech?

The WS229 comes with a 30USM as standard.
A push button mech will need to be incorporated into a WS229VH.


 

Does Clipsal have a single gang, IP rated, switch plate with a 15 or 20 amp mechanism?

We do not but you can put a 30USM into a 31VHWP-WE to achieve the same thing.

Does Clipsal have a single gang, IP rated, switch plate with a 15 or 20 amp mechanism?

We do not but you can put a 30USM into a 31VHWP-WE to achieve the same thing.

What colour knobs come with the 40RSM2 and RSM3?

This product comes standard with a Vivid White knob (VW). If any other colour is required a knob kit is required.
The part numbers are a 40RSM2KB and 40RSM3KB. The knob kit comes in all colours.

For further information please visit www.clipsal.com/Trade/search-results?q=40RSM



What 400mm deep fixed shelf fits the 3106N39C608 data cabinet?

The 400mm deep fixed shelf that fits the 3106N39C608 data cabinet is a 3106GSF1U40-BK.

What is the M rating of the WSF226 switch?

M80 is the correct rating for the WSF226.

It used to be M100 but the mechs were changed to 30USM which changed the M rating also.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=WSF226

 

Can 30USB be used in ML2025?

Yes. The part number ML2025I can be used with 30USBCM.


 

What is the replacement for a 30M20?

The replacement is a 30USM.

What is the part number for a Classic 2 gang switch in black with 1 switch and 1 fan controller?

The part number for a Classic 2 gang switch in black with 1 switch and 1 fan controller is - https://www.clipsal.com/Trade/search-results?q=C2032VH  & 30USM & 30CSFM
For further information , visit links below:-
https://www.clipsal.com/Trade/search-results?q=C2032VH
https://www.clipsal.com/Trade/search-results?q=30USM
https://www.clipsal.com/Trade/search-results?q=30CSFM
User-added image

Is the 60TSM 2 Way

 It is 2 Way if you use it with a 60TSSM

Will the 30RSM mechanism fit into a Saturn plate?

No, unfortunately this mechanism does'nt fit the Saturn series. However, this mechanism will fit into the coms Saturn series comunication plate 4031VH.

What colour knobs come with the 40RSM2 and RSM3?

This product comes standard with a Vivid White knob (VW). If any other colour is required a knob kit is required.
The part numbers are a 40RSM2KB and 40RSM3KB. The knob kit comes in all colours.

For further information please visit www.clipsal.com/Trade/search-results?q=40RSM


How to make a 2 gang Saturn OneTouch switch

You need to use part codes 4062TC + 2 x 60TSM

Is there a manual for the 140XSM 00100 Quantum analog simulator module ?

Attached you will find the documentation for the 140XSM00100 Quantum analog simulator module.

The Clipsal 30M20 is discontinued, What is the alternative part?

The alternative part for the Clipsal 30M20 is the 30USM: Universal Rocker Switch, 1-Way/2-Way, 250VAC, 20A.
 

What are the dimensions of the 3105PEN7440?

The dimensions of the 3105PEN7440 are 750mm (H) X 405mm (W) X 150mm (D).

Is the 600SM available in red

No, it only comes with White and Black covers.

Which Clipsal 30 Series mechs are available in 3S (Chrome Shadow)

Part codes which are available in 3S -  30M, 30USM, 30MI, 30MD, 30MBPR, 30M35, 32E450UDM, 32E450LM, 32E450TM 

PDL600SM - 600SM can it protect downstream or will it only protect the socket in that plate?

The 600SM protects all other devices on the circuit but it can only handle a limited number of surges.
For more information see attched installation sheet.

What is amp level of 30USB?

30usb has amp level of 1.2

For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USBCMsal.com/Trade/Products/ProductDetail?catno=30USBCM

What is the part number of the curved horizontal mounting flange to suit 400mm diameter surface?

2000MF400 is the Mounting Flange to suit 400mm diameter surface - horizontal. Dimensions are as follows:

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000MF400

What is the inductive load that can be switched by the 30USM?

The 30USM can switch an inductive load of 16A.

Some of the key features are:
  • Ability to switch fluorescent loads up to 16 AX
  • Reduced visible arcing and crackling
  • Modular 30 mech design suits most Clipsal switch plates

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM
 

 

What is part number for Anthracite fan knob to suit 40CSFM?

The part number for Anthracite fan knob to suit is a 40RSM3KB. 

Can i get a 40CSFM in any other colour, other than Vivid white?

The 40CSFM only comes in the colour Vivid White. However if another colour is required an additional knob kit can be purchased.
The knob kit comes in a packet with all 4 colour options. The part number is 40RSM3KB.

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=40RSM3KB

What surge protection can I use behind a powerpoint in the 600 series

 Use a PDL 600SM with a 600 series socket with an extra switch

PDL600SM SURGE PROTECTION MODULE Do we have in Black?

When you purchase a 600SM it comes with a White and Black cover and you can put on either one.

What is the difference in dimensions from the old 3106WC6U35 to the new 3106W06C604?

3106WC6U35 -350mm (H) X 600mm (W) X 350mm (D)
3106W06C604-gy- 363mm (H) X 600mm (W) X 400mm (D)

What is the difference in dimensions from the old 3106WC6U35 to the new 3106W06C604?

3106WC6U35 -350mm (H) X 600mm (W) X 350mm (D)
3106W06C604-gy- 363mm (H) X 600mm (W) X 400mm (D)

Is there a wiring diagram for the 40CSFM 3 Speed fan controller?

Please see the attached document on how to wire the 40CSFM 3 Speed fan controller.

What is the alternate for 60TSM, saturn OneTouch mechanism?

60TSM is replaced by 60TSRM3, OneTouch Switch Mech, is 3-Wire, 6AX, 220-240V AC.

Key Features

  • Touch sensitive control interface
  • Cool Blue LED Halo indicator
  • Audible alert tone
  • Reliable Control of many different load types within the home
  • Capable of up to 3 way switching
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=60TSRM3
 

Is there a Surge Protection Socket Outlet available in the 600 series?

PDL used to do a complete unit - The 695SP however, this is now obsolete. A Surge Protection Outlet can be made up of parts. You will need to use one of the sockets that have an extra switch space such as the 694X or the 695X and replace the extra switch with our Surge Protection Module, the 600SM.

 

What is the part number for a 30 series switch mech that will switch DC voltage?

The best option for a 30 series switch mech that will switch DC voltage is - 30USM, but as it has not been tested or rated for DC use there is no gaurantee as to how long it will last.
The higher the voltage and current to be switched the less switching action it will provide.
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=30USM
 

Is there a 30USB in a 2000 Series double power point?

No, unfortunately that part is not avaliable. However, there is a 2000 Series with a single power point and twin USB charger.
The partnumber is 2015USB2C.
Some of the key features are:
  • 2015 10A GPO
  • Twin 30USBCM USB Chargers
  • Surge, over-current and over-temperature protection
  • Cable compensation for optimised charging
  • Meets BC1.2 USB Charging Standard
  • Meets Class V Energy Efficiency in standby
  • Certified to all relevant safety and EMC requirements for Australia

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015USB2C
 



 

What is the altitude derating for a TeSys D-Line contactor?

Issue:​
What is the altitude derating for a TeSys D-Line contactor?

Product Line:
Digest 177 Section 18 : Contactors and Starters, IEC

Environment:
North American Products

Resolution:
The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

Voltage
3500m x 0.90
4000m x 0.80
4500m x 0.70
5000m x 0.60

Current
3500m x 0.92
4000m x 0.90
4500m x 0.88
5000m x 0.86

For example, an LC1D80 at 5000 meters:
- The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
- The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



 

How is PID programmed on the ATV320 drives?

Issue:
How is PID programmed on the ATV320 drives?

Product line:
ATV320, Altivar 320

Environment:
all

Cause:
To maintain pressure, temperature or flow within a system

Resolution:
Using the dial on the display, Push Enter and turn to CONF > FULL > FUN > PID.

Under the PID Regulator menu set:
PIF - PID feedback assignment

PIF1 - Min PID feedback
PIF2 - Max PID feedback
PIP1 - Min PID reference
PIP2 - Max PID reference

PII - Act. Internal PID ref

RPI - Internal PID ref


Min/Max PID Reference and Feedback are typically set to the range of the transducer.  Act. Internal PID turns on the internal set point.  Internal PID ref is the set point you want to maintain.  

Example:
You have a transducer, 4-20mA output follows a 0-100PSI range.  You want to maintain 40PSI pressure.  The recommended settings would be:
You will need to change the AI3 range from 0-20mA to 4-20mA from the I-O menu then AI3 then CRL3 change it to 4.0

PIF - AI3 
PIF1 - 0
PIF2 - 100
PIP1 - 0
PIP2 - 100
PII - yes
RPI - 40

This would maintain 40PSI (10.4mA feedback) in the system based on 4-20mA signal coming into AI3.  
Feedback < 10.4mA will increase motor speed. 
Feedback > 10.4mA will decrease motor speed.
If the VFD reaction needs to be reversed, set PiC, PID correct reverse, to YES.,

What is the Configuration Chart for the Saturn OneTouch range?

The Configuration Chart for the Saturn OneTouch range is:

4061TC  (1 Gang Grid and Cover Only)
4062TC  (2 Gang Grid and Cover Only)
4063TC  (3 Gang Grid and Cover Only)
4064TC  (4 Gang Grid and Cover Only)
4066TC  (6 Gang Grid and Cover Only)
4061ATC (1 Gang Architrave Grid and Cover Only)
4062ATC (2 Gang Architrave Grid and Cover Only)

All of the above Cover plates can be configured to be Switches or Dimmers to your requirements by ordering the Grid & Cover plate and
then the matching OneTouch Dimmer or Switch.  60TSM (OneTouch switch 400W) or 60TDM (OneTouch Dimmer 350W)