Quantcast

Clipsal Iconic Study Rocker 10 Pack

Vivid White | Clipsal Iconic Study Rocker 10 Pack

Clipsal Iconic Study Rocker 10 Pack

Item Number: 40STR-VW

Build this product i

Retail
$33.55
RRP (Inc. GST)

Save time and energy with the convenient Clipsal Iconic Study Dolly Rocker switch that allows you to turn on and off the lights to your study or office at the flick of a switch. Easy to read pictogram allows for clear and universal identification.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width23 mm

Height icon

Height23 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

rocker

Colour tint

vivid white (VW)

Physical

Quantity per set

set of 10

Marking

study

Switch function

2 positions

Height

23 mm

Width

23 mm

Depth

9 mm

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

14 g

Package 1 Height

9.17 mm

Package 1 width

98 mm

Package 1 Length

175 mm
Show all specifications

Frequently Asked Questions

hide show

Preventa XCS_CSA certificate of the XCSPA, XCSPL, XCSPR, XCSTA, XCSPL, XCSTR plastic safety switches

Please find attached the CSA certificate of the XCSPA, XCSPL, XCSPR, XCSTA, XCSPL, XCSTR plastic safety switches

Preventa XCS - CCC certificate of the XCSPA, XCSTA, XCSPL, XCSTL, XCSPR, XCSTR safety limit switches (origin France)

Find attached the CCC certificate of the XCSPA, XCSTA, XCSPL, XCSTL, XCSPR, XCSTR safety limit switches produced in France, and valid up to September 2024

XCSPL XCSTL XCSPR XCSTL safety switches - EC/EU declaration of conformity

Find attached 2016 update EC/EU declaration of conformity for our XCSPL XCSTL XCSPR XCSTR plastic safety switches. The Low Voltage and EMC directive changed.

Osisense XC_EAC certificate of the XCMD, XCK, XCS ... limit switches and safety limit switches

Please find attached Russian EAC certificate of our XCMD, XCK, XCS ... switches, valid up to February 2025

What does "CT/PT Correction Points" mean in the Instr Xformer Correction (ITC) Module on an ION meter?

In ION meters, The Instr Xformer Correction (ITC) Module is used to correct inaccuracies in the current transformers (CTs) and potential transformers (PTs). This module applies correction factors for ratio errors and phase angle errors to instrument transformers, hence, reducing or eliminating the need to replace transformers in installations where high-accuracy is required.
The module in summary requires to enter a set of example data, then applies interpolation based on the data set given to the correct inaccurate Voltage-Current values. In the module, the Phase Correction Data setup register is used to enter a string of delimited pairs of the test points and associated error for the phase angle of the CT or PT. The test point is expressed as a percentage of the rated secondary nominal rating. The phase angle error is expressed as a real value in minutes.

The Test Point mentioned above is also known as CT/PT Correction Points in industry.


Date Created: June 4, 2009
Last Revised: July 16, 2009
Public
Original Author: KG
All content © 1992-2009 Schneider Electric


Legacy KB System (APS) Data: RESL199373 V1.0, Originally authored by MiNe on 07/17/2009, Last Edited by MiNe on 07/17/2009
Related ranges: ION8600, ION7550/ION7650

Why is the trip C.B. feature not available for Sepam 40?

Issue
The option to select trip CB is not available in the protections.

Product Line
Sepam 40

Resolution
The Trip C.B. feature for ANSI 46 is only available if CB Control is set to ON.


 
Show More