Clipsal Iconic Sensor Rocker 10 Pack

Clipsal Iconic Sensor Rocker, 10 Pack

Clipsal Iconic Sensor Rocker 10 Pack

Item Number: 40SR-VW

Retail
$33.55
RRP (Inc. GST)

The Clipsal Iconic Sensor Dolly Rocker switch is the perfect way to gain greater control and easily turn on and off your light sensors. Each sensor switch has an easy to read pictogram that transcends language.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width23 mm

Height icon

Height23 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

rocker

Physical

Quantity per set

set of 10

Marking

sensor

Switch function

2 positions

Height

23 mm

Width

23 mm

Depth

9 mm

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

14 g

Package 1 Height

9.17 mm

Package 1 width

98 mm

Package 1 Length

175 mm
Show all specifications

Frequently Asked Questions

hide show

Does PowerLogic SCADA support waveform data of ION meters?

No, Powerlogic SCADA (PLS) currently does not support the waveform data from ION meters; valid through PLS v7.10 SR3.
Waveforms from the following devices are currently supported as of v7.10 SR3: Circuit Monitor 3000s, Circuit Monitor 4000s, Power Meter 800s, and Sepam 20s, 40s, and 80s.


Legacy KB System (APS) Data: RESL200266 V2.0, Originally authored by KBAdPM on 10/16/2009, Last Edited by MaTh on 12/01/2010
Related ranges: PowerLogic SCADA 7.1

Sepam is showing a reverse rotation Alarm.

Issue   
On the front display of the Sepam it is showing a reverse rotation Alarm.

Product Line   
Sepam Series 40
Sepam Series 80

Cause   
The Sepam is looking at the voltage phase rotation.  On the Sepam 40s it is looking for an ABC rotation.  The Sepam 80s it can be wired ABC or ACB.

Resolution   
Sepam 40:
The only way to fix the reverse rotation alarm is to re-wire the voltages to an ABC rotation even if its a ACB rotation.  To help on the wiring please click here for the Sepam 40 wiring diagram.

Sepam 80:
One can just make the changes in SFT2841 by going to the General characteristics tab.  In the Electrical network box look for Phase rotation direction and select which rotation is needed.