Mech Switch 1way 32A 250V VW

Clipsal Iconic - Switch Mechanism, 1-Way, 250V, 32A

Catalogue Number: 40M32
Mech Switch 1way 32A 250V VW
Colour: Vivid White
Colour: Per UOM Std.
  • Vivid White 1 PCE
Added to cart

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switch
Device application
  • small motor loads
  • cooking appliances
    • Colour tint
      vivid white
      Quantity per set
      set of 20
      Device presentation
      mechanism
      Control type
      rocker
      Switch function
      1-pole 1-way
      Rated current
      32 A
      [Ue] rated operational voltage
      250 V
      Material
      plastic
      Connections - terminals
      screw terminal
      Height
      23 mm
      Width
      23 mm
      Depth
      32 mm
      Net weight
      0.016 kg
      EU RoHS Directive
      Compliant
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Product Environmental

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the part number of a dolly to suit 40M32, Iconic 32A mechanism?

      40R32 is the part number for a dolly to suit 40M32. It is available in Vivid White (VW), Warm Grey (WY), Cool Grey (CY) and Anthracite (AN).

      For further information, please visit https://www.clipsal.com/Trade/search-results?q=40r32

       

      What size cable will the T100-BK terminals accomodate?

      10mm2 to 50mm2

      Saturn - is there an option for banana mechanisms in this range?

      YES - 30BCRM OR 30BCBM OR both in a 4031 or 4032 Communication plate.

      What colours are the PDL 680M32 available in?

      The PDL 680M32 (switch module, 1 way, 2 terminal, 32A, 240V) is only available in white or black.
      https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=825

      Is 40MD20 double pole, single throw switch mechanism?

      Yes, 40MD20 is an Iconic double pole single throw switch mechanism rated to 20AX, 250V, 1 way.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MD20

      What plug suits the 402/32outlet?

      The plug that suits the 402/32 outlet is the 492/32.

      what is the surface socket for 492/32 ?

      402/32

      Will the 60R32 fit into a 4062VH plate ?

      No , The 60R32 series mechs are only designed to go into the 4025XA and 4025XUA plate styles. If Mechs over 32 amp are required for Saturn plates then you will need either 4031VH plate and 30M35 series mechs or the dedicated cooker plates 4061D32 or 4061/45 series

      What Saturn Zen 2 gang plate accommoddates 30m35 mech?

      The Saturn Zen 2 gang  plate accommoddates 30m35 mech is Z4032VH.

      Can part number 30M35 be used in 2031V66?

      No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

       

      Can a Clipsal 30MD20 be used as a changeover switch?

       No - It is just a 2 pole switch
      But a 30MD2 is a 2p 2way (6 terminals)

      Fuse and circuit breaker rating for LXM32

      Issue:
      What is the fuse or circuit breaker rating for LXM32 drives?

      Product Line:
      LXM32

      Resolution:
      For 115VAC and 230VAC drives, the maximum fuse to be connected upstream is 25 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic.
      For 400VAC and 480VAC drives, the maximum fuse to be connected upstream is 30/32 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic.

      Which RS-232 cable is used for communication from PC to SCADAPack 4000 series Transmitters?

      Schneider Electric 3-wire serial cable p/n TBUM297801 is used to connect from an 3-pin based RS-232 port on the SCADAPack 4000 series Transmitter (4012, 4032, 4102, 4203DR, 4203DS) to DE-9P connector on a DTE such as a PC.

      Does the 30M35 come in dark grey?

      The 30M35 does not come in dark grey.

      However it does come in Chrome Shadow or Soft Grey.

      For further information please visit https://www.clipsal.com/Trade

      Can a 30M35 mech fit into Saturn plate

      The 30m35 will only fit into any Saturn plate that can accommodate any 30 series mech eg Saturn plates 4031VH to 4036VH
      for information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=4031VH

      User-added image

      Will the 60R32 fit into the 4025XA ?

      Yes, the 60R32 series are designed only to be fitted into the 4025XUA and 4025XA series

      What size cable does the 60R32 accommodate?

      The 60R32 switch mechanism accommodates up to  4 x 1.5mm2 or 3 x 2.5mm2 or a single 4mm or a single 6mm.

      Does the 60R32 suit the Zen range also?

      Yes, the 60R32 suits the Zen range.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=60R32

       

      What neutral link will 70mm2 cable fit in?

      The neutral link big enough for 70mm2 cables would be the BP350/7.

      Some of the key features are:
      • Black base and cover
      • Two screw per take off tunnel
      • Incoming cables clamped with single grub screw
      • 2 tunnels: 15.0 mm Diameter accommodate 120 sq mm cables
      • 2 tunnels: 9.5 mm Diameter accommodate 50 sq mm cables
      • 2 tunnels: 8.0 mm Diameter accommodate 35 sq mm cables
      • 1 tunnel: 5.5 mm Diameter accommodates 16 sq mm cables
      • Terminal bar: 25.4 x 19 x 95.3 mm
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=BP350/7​

       

      What is the socket to suit the Clipsal 492 492/32 492/32HD

      Socket to suit is 402 series

      402  402/32

      Can I fit 2 x 2.5 cables in the terminals for a 402/32

      Yes - as its rated at 15A 4 x 2.5mm cables will fit

      What is the data jacks that fits the Saturn 4032VH data plate

      You will need to use the 4032VH plates and any Clipsal 30 Series data and AV mechs,  
      these plates will aslo fit any 30 series switch mech,
      EG  30TV75M, 30PFM, 30HDMIA, VDIB17756U-we

      What is the part number for Iconic intermediate switch mechanism?

      40MIL is Clipsal Iconic Intermediate Switch Mechanism rated to 250V, 10A with LED indicator.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MIL

       

      Is there a mains connection box that can accommodate 90mm square cable?

      No the largest can accommodate up to 50mm2 and the part number is a 650/4/35-BK.

      What is the diameter of the LXM32 power cable?

      Please see attached file
       

      Is there a 35A double pole mechanism?

      No. We have 30M35 which is 1 pole, 35A mech.

      Video: LXM32 - with-without tunning

      Read actual torque on a LXM32 in SoMachine

      Issue:
      Read LXM32 actual torque in SoMachine

      Product Line:
      LXM32M, LXM32A, LXM32C

      Resolution:
      The easiest way to read the actual torque on a LXM32 drive is to use the function block MC_ReadActualTorque_LXM (See attached screenshot)

      What is the mechanism that goes into 4025XUA

      60R16 which is rated at 16 amps and used for general lighting etc.
      60r32 which is rated at 32 amps and can be used for stoves and ovens.

      Please see below link for  further documentation
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=60R32

      What colour of 60R32 mechanism will suit Saturn horizon 4025XA or 4025XUA plates?

      60R32-CC, 250V, 32A switch mechanism  will suit Saturn horizon 4025XA or 4025XUA plates. CC is for charcoal.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=60R32

      What is the part number for a 30 series switch mech , labelled ZONE 1 , 2 , 3 ?

      The part number for a 30 series switch mech , labelled ZONE 1 , 2 , 3 is - 30MZ1 , 30MZ2 , 30MZ3
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=30MZ1

      Looking for the CN10 connector for LXM32 drive

      Issue:
      Looking for the CN10 connector for the LXM32 drive

      Product Line:
      LXM32

      Resolution:
      The CN10 connector on the LXM32 drive cannot be sold alone.
      It comes in a complete connectors kit, part# VW3M2202. This kit is included in the box when buying a LXM32 drive and can be ordered separately.

      Is there a 35A Mech for Saturn Zen Series

      No there is no saturn mech available. There is either the Z4061/45 cooker switch plate or the 30M35 in a Z4031VH Plate

      What is the part number for the 30M35 in chrome shadow?

      The part number is 30M35-3S, but not anymore available for sale in New-Zealand.

      What is part number for 35Amp mech to suit Saturn?

      The part number 30M35 mech will go into 4031VH plate. 
       

      How to save or restore the LXM32 parameters using a SIM card?

      Issue:
      Save or restore the LXM32 parameters using a SIM card

      Product Line:
      LXM32 servo drives

      Resolution:
      Please see attached document.

      Autotune a LXM32 servo drive through SoMove

      Issue:
      Procedure to autotune a LXM32 drive through SoMove

      Product Line:
      LXM32
      SoMove

      Resolution:
      The attached manual shows how to autotune a LXM32 drive through the SoMove software.
       

      Getting error E7701 on LXM32 drive

      Issue:
      Getting E7701 on the LXM32 drive

      Product Line:
      LXM32

      Resolution:
      E7701 is a system error: Timeout during connection to power stage.
      The drive will have to be replaced. This error cannot be reset.

      Video: How to upgrade the firmware of the LXM32

      Is there a cooker mech for 4025XA?

      Yes, 60R32 or 60R32COOK - 32A , mech. Do not have a double pole version.

      What is the part number for the extra mechanism 32A that fits the 4025XU?

      the part number is 60R32

      What is the recommended spacing for 22mm pushbuttons ?

      Issue:
      What is the recommended  spacing for  22mm pushbuttons ?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      Horizontal spacing is 1.18`` or 30mm, vertical spacing is 1.57`` or 40mm, hole size 0.88`` ( recommended 0.89`` ) or 22.5mm


       

      What is the size of the inter conductor for the N-series recloser cables (38kV)?

      This size will vary depending upon the rating of the conductors:


      • 1. 250A 80mm2
        2. 340A 120mm2
        3. 400A 180mm2
        4. 630A 240mm2
        5. 800A 400mm2

        These are shown in more detail in the attached guide.

        Olex cables.pdfOlex cables.pdf


      Legacy KB System (APS) Data: RESL212274 V1.0, Originally authored by DaFr on 08/09/2013, Last Edited by DaFr on 08/09/2013
      Related ranges: Others protection relays

      How can a floating point value be moved into 4XXXX registers in a Quantum PLC with 984 LL?


      A floating point value can be moved into 4XXXX registers with the equation network. An example of moving a floating point value of 123.456 into registers 40001 and 40002 is shown below:

       

      Is there a backing plate for the 402/32?

      No, unfortunately the 402/32 does not have a backing plate.

      Some of the key features are:
      • Single outlet
      • Front connection
      • 2 polarised flat pins

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=402/32



       

      What is the undervoltage limit for the LXM32 drive?

      Issue:
      Undervoltage limit for the LXM32 drive?

      Product Line:
      Lexium 32

      Resolution:
      The undervoltage limit varies depending on the servo drive's part number.
      The attachment shows the different limits.

      Getting error E7701 on LXM32 and unable to reset

      Goals and Symptoms
      Getting error E7701 on LXM32 and unable to reset

      Facts and Changes

      LXM32

      Causes and Fixes

      E7701:System error: Timeout during connection to power stage.
      You can try to update the firmware if you have an older revision.
      This is an error in the power stage so most of the time, you need to send the LXM32 back for replacement

      Error A320 on a LXM32 drive

      Issue:
      What is error A320 on a LXM32 drive?

      Product Line:
      Lexium 32

      Resolution:
      A320 is a following error. The parameter is _SigLatched Bit 8
      Reason could be a high external load or an acceleration that is too high.
      Solution is to reduce external load or acceleration or use a differently rated drive.
      Error response can be adjusted via parameter ErrorResp_p_dif

      How to auto-enable the LXM32 drive using SoMove?

      Issue:
      Auto enable the LXM32 drive using SoMove

      Product Line:
      LXM32

      Resolution:
      Instead of having to activate an input in order to enable the LXM32 drive, you can set the following parameters to automatically enable the drive on power-up:
      In SoMove (See attached):
      Axis Configuration > IO_AutoEnaConfig = ON
      Axis Configuration > IO_AutoEnable = AutoOn

      Connect and change parameters on a LXM32 drive using SoMachine

      Issue:
      Can I connect and change parameters on LXM32 servo drive using SoMachine?

      Product Line:
      SoMachine

      Resolution:
      In SoMachine, when you add a LXM32 drive to the network, you can double click it and go to the 'Configuration of the device' tab, where you can see a SoMove-like screen (See attached).
      Just like the SoMove interface, you can connect to the drive and upload/download/edit parameters.
      Show More