Mech Switch 1/2way 10AX 250V
40M
Mech Switch 1/2way 10AX 250V
40M

Clipsal Iconic Switch Mechanism, 1-Way/2-Way, 250V,10AX

Catalogue Number: 40M
Mech Switch 1/2way 10AX 250V
40M
Mech Switch 1/2way 10AX 250V
40M
Retail
$13.06
RRP (Inc. GST)

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switch
Device application
lighting
Colour tint
vivid white
Quantity per set
set of 20
Device presentation
mechanism
Control type
rocker
Switch function
1-pole 1/2-way
Rated current
10 A
[Ue] rated operational voltage
250 V
Material
plastic
Connections - terminals
screw terminal
Height
23 mm
Width
23 mm
Depth
32 mm
Net weight
0.016 kg
Package 1 Weight
16 g
Package 1 Height
22 mm
Package 1 width
22 mm
Package 1 Length
31 mm
EU RoHS Directive
Under investigation
Environmental Disclosure
ENVPEP120506EN

Documents & downloads

hide show

Frequently Asked Questions

hide show

What mechs fit into Pro Series grids?

 Pro Series is compatible with all PDL300 Series & Clipsal 40M mechanisms.

What is Iconic part no for cap to suit 40M

Part no 40AR
for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=40AR-WY

User-added image

 

Is there a mounting block that suits the 40?

Yes, there is a mounting block for the 40. The part number is 447.

Some of the key features are:
  • Moulded mounting blocks
  • With metal inserts
  • 3 mounting screw positions
  • suits 40, 40D and switches with 115x48 mm flush plates and 98 mm mounting centres

For further information please visithttps://www.clipsal.com/Trade/Products/ProductDetail?catno=447

 

Power loss of our RFI filter VW3A58407 and VW3A58408.

Goals and Symptoms

Power loss of our RFI filter VW3A58407 and VW3A58408.

Facts and Changes

VW3A58407
VW3A58408.

Causes and Fixes

This information is not available for the moment.
401 = 5 w
402 = 11 w
403 = 11 w

No information for 407 and 408.


Legacy KB System (APS) Data: RESL156483 V3.0, Originally authored by on , Last Edited by on
Related ranges: Altivar 58

What is the recommended maximum cable length (with part numbers) for the TM3BCEIP Bus Coupler?

Issue
What cable do I use for the TM3BCEIP Ethernet/IP or Modbus TCP Bus Coupler?
What is the maximum length for the cable(s)?

Product Line 
Modicon TM3

Environment
Distributed I/O Modules for M221, M241, M251, M262 PLCs

Resolution
The cabling options for the TM3BCEIP Bus Coupler module are as follows.
All cables listed below are Ethernet Shielded cables for DTE connections with equipped with RJ45 connectors at each end.

For environments without Electromagnetic Interference (EMI), the maximum cable length recommended is 80m. Part numbers are as follows:
CE compliant cables:
490NTW0002 - 2m (6.56 ft)
490NTW0005 - 5m (16.4 ft)
490NTW00012  - 12m (39.37 ft)
490NTW00040 - 40m (131.23 ft)
490NTW00080 - 80m (262.47 ft)

UL compliant cables:
490NTW0002U - 2m (6.56 ft)
490NTW0005U - 5m (16.4 ft)
490NTW00012U  - 12m (39.37 ft)
490NTW00040U - 40m (131.23 ft)
490NTW00080U - 80m (262.47 ft)

For harsh environments with Electromagnetic Interference (EMI), the maximum cable length recommended is 10m. Part Numbers are as follows:
CE compliant cables:
TCSECE3M3M1S4 - 1m (3.28 ft)
TCSECE3M3M2S4 - 2m (6.56 ft)
TCSECE3M3M3S4 - 3m (9.84 ft)
TCSECE3M3M5S4 - 5m (16.4 ft)
TCSECE3M3M10S4 - 10m (32.81 ft)

UL compliant cables:
TCSECU3M3M1S4 - 1m (3.28 ft)
TCSECU3M3M2S4 - 2m (6.56 ft)
TCSECU3M3M3S4 - 3m (9.84 ft)
TCSECU3M3M5S4 - 5m (16.4 ft)
TCSECU3M3M10S4 - 10m (32.81 ft)

Is part number 49M available in Anthracite?

No. Unfortunately, the part number 49M  is only available in Vivid White.

What is the part number for a 2 gang Iconic switch plate and switch mech and dimmer?

The part number for a 2 gang Iconic switch plate and switch mech and dimmer is - 3042HA , 40M & 41E300PBUD2SM

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3042HA
https://www.clipsal.com/Trade/search-results?q=40M
https://www.clipsal.com/Trade/search-results?q=41E300PBUD2SM
User-added image

Can Xanbus Cable be installed Underground for use with XW/XW+/CSW System?

Yes, but requires the use of proper outdoor/underground cables of the correct build and standard and is not to exceed the maximum length - Xanbus total 40m @ 250kbps.
Requires the use of Ethernet Cable designed for underground use. Can use CAT 5e or CAT 6 JELLY FILLED cable with correct outdoor rating and is compliant with local standards.
 

What is the part number of Iconic LED indicator lights on the mechanism?

40MLEDW is the part number of Iconic LED indicator lights on the mechanism. It can be used on 40M, 40USM and 40MI only to upgrade them to luminous mechanisms. They are warm white LEDs and can be easily wired and set as locator or indicator.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=40MLEDW&mg=341&g=200000362

What are the ATV630D11N4 Dimensions and weight?

Dimension = 409 x 171 x 233
7.7kg
 

Is there a code for a spare 405 key for Himel enclosures?

No, but a PRA90039 is the least costly lock, supplied with 2 x 405 keys.

What is the wattage for a Clipsal CE250 ceiling fan

 The wattage is 40w
Show More