Clipsal Iconic KITCHEN Rocker 10 Pack

Clipsal Iconic KITCHEN Rocker, 10 Pack

Clipsal Iconic KITCHEN Rocker 10 Pack

Item Number: 40KR-VW

Retail
$33.55
RRP (Inc. GST)

Add a new level of control, convenience, and efficiency to residential or commercial projects with the convenient Clipsal Iconic Kitchen Dolly Rocker switch. Easily control the flow of power to lighting with sleek kitchen switch.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width23 mm

Height icon

Height23 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

rocker

Physical

Quantity per set

set of 10

Marking

kitchen

Switch function

2 positions

Height

23 mm

Width

23 mm

Depth

9 mm

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

14 g

Package 1 Height

9.17 mm

Package 1 width

20.39 mm

Package 1 Length

23.25 mm
Show all specifications

Frequently Asked Questions

hide show

What is the part number for a 1 pole surge arrester with a 40kA rating?

The part number for a 1 pole surge arrester with a 40kA rating is - 940RMT/1

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=940RMT/1
 

What is the part number for a Schneider 1 pole 40kA surge arrester?

The part number for a Schneider 1 pole 40kA surge arrester is - A9L40101

For further information visit link below:-
https://www.schneider-electric.com.au/en/search/A9L40101
User-added image

 

What is the surge protection replacement for an old PDL 40kA surge protection

 You can use a 16561

What is the part code for a NS breaker 3P 250Amp 40kA with 200Amp trip unit and fit busbar system

You can use an LV431406 frame with a LV431431 trip unit and also LV429372 busbar adaptor

What surge protection is offered in the Altivar Field Drives?

Issue:
What surge protection is offered in the Altivar Field Drives?

Product line:
Altivar Field drive, IFD

Environment:
all

Cause:
n/a

Resolution:
The standard field drive comes with the SDSA surge protectors which offer 40kA surge protection.  With factory option H09, the surge module is upgraded to the HWA series which is 80kA. 

What is the maximum number of XR frames allowed with a Symmetra PX 20, 40 and 80kW solution?

 

Issue:
Symmetra PX; What is the maximum number of XR frames allowed with a Symmetra PX solution?


Product line:
Symmetra PX 20, 40, 80kW


Environment:
All models, all serial numbers
 

Cause:
The maximum number of XR frames allowed with a Symmetra PX solution is 4.



Resolution:
"This depends on the size of the Symmetra PX Main Frame.

For a Symmetra PX 20 or 40kW Frame, the maximum number permitted is 4 fully populated (Battery Frames) XR frames. This will give a runtime of 1 hr 40 mins for a 40kW load. The Battery Monitoring Card cannot handle more than this number of addresses for XR frames.

The part number for a fully populated XR frame is SYCFXR8-8. This consists of the XR frame with 8 Batteries Modules. There are 4 Battery Units in a Module this equals an XR frame with 32 Battery Units installed.

For a Symmetra PX 80kW Frame, the maximum number of additional cabinets is 3 fully populated XR frames. This would make for a total of 4 battery frames in addition to the Main UPS frame which houses the Power Modules. This will give a runtime of 35 mins for an 80kW load.

The part number for a fully populated 80Kw XR frame is SYCF8BF-8. This consists of the XR frame with 8 Batteries Modules. As there are 4 Battery Units in a Module this equals an XR frame with 32 Battery Units installed.


Note: Both battery cabinets listed above may be purchased empty (without batteries) by omitting the ""-8"" at the end of the part number."



 

Symmetra PX; 20-80k Seismic Anchoring Brackets

 

 

Issue:

Symmetra PX 20-80k Seismic Brackets

 

Product line:

Symmetra PX 20-80

 

Cause:

The Symmetra 20-80k systems do not have a seismic kit

 

Resolution:

The customer must use the shipping bolt down brackets to bolt the UPS to the floor.  If they have thrown them away then they can buy the AR8112BLK.  See PDF for install drawing

No testing was done for PX40 platform.  However, seismic calculations were performed for PX40 by a Professional Engineer in California.

Note:  PX40 does not have OSHPD pre-approval.  If the customer must have 40kW of PX that is OSHPD pre-approved, they would have to go with the PX100 platform.  That has been tested and carries a, OSHPD pre-approval.

See attached file AKAR-8LGMA8_R0_EN.pdf

 

Symmetra PX1-PX2; What happens when PX1, PX2 and 250/500K PX is EPO'd

Issue:
What happens when PX1, PX2 and 250/500K PX is EPO'd
 
Product line:
Symmetra PX
 
Environment:
All models, all serial numbers
 
Cause:
This document describes how the Symmetra PX reacts to the EPO circuit being activated. Emergency Power Off (EPO) is the capability to power down a piece of electronic equipment or an entire installation, in the case of an emergency, from a single point by activating a push button.
 
For 20K, 40K, 80K PX:
If the EPO circuit in the Symmetra PX is activated the System Enable Switch turns to the off position, the DC Breaker in the Main Frame or in the XR Frame (80kw units only) also switches to off. Mains feed CB will be tripped on ISX PDU. There is no power on the output of the XR Battery Frames or on the output of the Symmetra PX UPS.
 
An EPO event is not recorded in the Event Log.
 
For 100K PX:
Only the Battery CBs on XR frames will be tripped. Customer would need to have optional shut trip on Upstream CB to turn off input power to UPS.
 
For 250K/500K PX:
All Battery CBs on battery frames and Q2 will be tripped
 
Resolution:
Reset EPO switch and follow proper procedures to restart UPS
 

How to set self test day and time on Symmetra UPS products

Issue:
How to set self test day and time on Symmetra UPS products
 
Product line:
Symmetra PX, Symmetra PX2, Symmetra LX, Symmetra RM
 
Environment:
All Product models 160KVA and below, all serial numbers
 
Cause:
The self test interval can be set by the user, but the day/time of the test cannot be programmed.
 
Resolution:
Two actions will reset the counter for the self test interval.
1) A UPS load on command.
2) An adjustment to the self test interval setting.
 
*note that running a manual self test will NOT affect or set the automatic self test timer.
 
Example:
You would like your self test to run every two weeks on Tuesday morning around10 AM – a time you are likely in the office.
 
Suggested method example:
On Tuesday, at 10am, change the self test setting
(esc) to main UPS menu
Setup (enter)
Other (enter)
Self test (enter)
(up/down) change to never (enter)
(enter again) change to 14 days (enter)
 
Your UPS self test should now run 14 days from this day and time.
 
*in the Symmetra PX 48, 100, 160 kVA the menu path is:
UPS -> UPS Configuration -> Other -> Self test
*the self test schedule (interval) can also be adjusted through the network interface.
 
 
Remember that anytime the UPS is commanded on, this timer will also reset.  If an extended power outage causes your UPS to fully drain batteries and shutdown, the self test day/time will be reset to when the UPS is turned back on. Also, if your UPS was turned off while in maintenance bypass for a repair, upon restart the self test counter would also be reset.  For either of these scenarios, you will need to reset the counter as described above at your chosen day and time.
 
 
 

Video: How to check the input and output diodes on ATV61/71 drives

Issue:
How do you check the input diodes and output IGBTs on ATV61/71 drives?

Product line:
Altivar 61 & Altivar 71

Environment:
All models, all serial numbers 

Cause:
Drive has faulted. Customer wants to do a full diode and IGBT check on the drive to see if it is functional.

Resolution:

Warning: This test needs to be done with the power off to the drive and the DC bus discharged.

Sizes 25HP and below
Check input:
Using a digital Fluke multimeter or similar meter set to the diode scale. Measure from L1, L2, L3 to PA/+. Your meter should read 0.3 to 0.7 V in the forward bias direction and 'OL' in the reverse bias direction.
Using the meter in diode scale, measure from L1, L2, L3 to PC/-. Your meter should read 0.3 to 0.7 V in the forward bias direction and 'OL' in the reverse bias direction. 
Check output:
Now measure the output terminals the same way. Be sure your meter is set in diode scale and measure T1, T2, T3 to PA/+. You should read 0.3 to 0.7v in the forward bias direction and 'OL' in the reverse bias direction. 
Measure T1, T2, T3 to the PC/- terminals. Your meter should read 0.3 to 0.7v in the forward direction and 'OL' in the reverse direction.



On 30HP and above sizes
Using the meter in Ohm scale, check L1, L2, L3 to PA/+ you will read 40k Ohms or higher in both forward and reverse direction.
Put your meter in the diode scale and from L1, L2, L3 to PC/-. Your meter should read 0.3 to 0.7v in the forward bias direction and 'OL' in the reverse bias
Now check T1, T2 ,T3 to PA/+ in diode scale. Your meter should read 0.3 to 0.7v in the forward bias direction and 'OL' in the reverse direction.

Network Air FM unit spare parts list

Issue:
Network Air FM unit spare parts list

Product line:
FM35-50, ACFM400, ACFM200, IR40

Environment:
All Serial Numbers

Cause:
Install

Resolution:
Please contact Cooling Tech Support to confirm the part numbers before quoting as some may have changed. 888-695-6500 Option 2, Option 2, Option 2

 
25 Pin Cable Lower (Downflow) 940-0161A  
 
25 Pin Cable Lower (Upflow) 940-0162A  
25 Pin Cable Upper 940-0160A  
35 PISTON FLOW RATER ORIFICE .070  RELSD ITEM  875-4249             
40 PISTON FLOW RATER ORIFICE .080  RELSD ITEM  875-4250             
50 PISTON FLOW RATER ORIFICE .090  RELSD ITEM  875-4251             
ADAPTER ROTO 1 1/4"-12R 7/8"SWT 875-4183 Glycol/Water LL  
ADAPTER ROTO 1"-14R 7/8"SWT (indoor rec'r) 875-4182 Glycol/Water & Air LL  
ASSEMBLY FLOW RATER FM 35       RELSD SKU 0M-3899               
ASSEMBLY FLOW RATER FM 40       RELSD SKU   0M-3900              
ASSEMBLY FLOW RATER FM 50       RELSD SKU   0M-3901              
ASSY DOOR FRONT CENTER DF BLACK 0M-74763  
ASSY DOOR FRONT CENTER UF BLK 0M-74791A  
ASSY FLOW-RATER FM35 W/ CAPILA  UNRELEASED  0M-6897              
ASSY FLOW-RATER FM40 W/ CAP LI  UNRELEASED  0M-6898              
ASSY FLOW-RATER FM50 W/ CAP LI  UNRELEASED  0M-6899              
Baying Kit FM50 0M-74480  
BLOWER ASSY 35-50kW - Spare Part W0M-74736  
BODY FLOW RATER BRASS FM SERIE  RELSD ITEM  875-4248             
CAT5 for EXP unit 0W0797  
CD NETWORKAIR FM NTWRK MNGMT CARD 991-0277A  
CKT BKR 3P 20A 480VAC 6KAIC  (compressors FM 50 ONLY) 530-0203 S283P-K20
CKT BKR 3P K 16A 480Y/277 SUPP (compressors FM 35 and 40) W530-0202  
CKT BKR 3P K 20A 480Y/277 SUPP (compressors FM 50 ONLY) 530-0203A S203P-K20
CKT BRKR 3P 100A 600V W/SHUNT SADDLE 530-0652  
CKT BRKR 3P 150A 600V W/SHUNT SADDLE 530-0654  
CKT BRKR 3P 25A 480V W/SHUNT 530-0556  
CKT BRKR 3P 30A 600V W/SHUNT SADDLE 530-0657  
CKT BRKR 3P 40A 480V W/SHUNT 530-0558  
CKT BRKR 3P 40A 600V W/SHUNT SADDLE 530-0659  
CKT BRKR 3P 50A 600V W/SHUNT SADDLE 530-0660  
CKT BRKR 3P 60A 480V W/SHUNT 530-0673  
CKT BRKR 3P 70A 600V W/SHUNT SADDLE 530-0662  
COIL CLEANER, FIELD FIX SOLUTION #3 690-0155  
COIL SOLENOID 24V 50/60HZ - MKC-1 451-0125  
COIL SOLENOID 24V 50/60HZ - MKC-2 450-0296  
COIL V ASSY FM 35 KW DX 875-0398B  
COIL V ASSY FM 40 KW DX 875-0403A  
COIL V ASSY FM 50 KW DX 875-0406B  
CONDENSATE PAN DRAIN VACUUM FORMED FM35-50 870-79142  
CONDENSATE PUMP HIGH LIFT 208-230V 491-0088A / W491-0088 A5X-2AP-230
CONDENSATE PUMP HIGH LIFT 460-480V 491-0089A / W491-0089 A5X-1AP-460
CONTACTOR,NR 24VAC 1NO () 451-0141 A16-30-10-81
CONTACTOR,NR 24VAC 1NO () 451-0143 A40-30-10-81
CONTACTOR,NR 24VAC 1NO (compressor [K1 & K2]) 451-0105 A30-30-10-81
CONTACTOR,NR 24VAC 1NO (humidifier [K3] & heater [K4]) W451-0104 A9-30-10-81
Door Assy FRONT CENTER DF BLACK 0M-74763  
Door Assy FRONT CENTER UF BLK 0M-74791B  
Door Assy FRONT LH DF/UF RrearReturn BLK 0M-74888A  
Door Assy FRONT LH UF FR BLK 0M-74889B  
Door Assy FRONTT RH DF BLACK 0M-74957A  
Door Assy FT RH UF BLACK 0M-74790A  
Door Assy LH SIDE FM UF BLACK 0M-74546A  
Door Assy PANEL REAR 0M-74892  
Door Handle Assembly (old handle: 840-0187) 840-0717A & pawl (870-79579)  
Duct Collar Downflow ACAC74495  
Duct Collar Upflow ACAC74494  
Emergency Power Off EPW9  
Filter Air 30% UF & DF 5/Unit 756 X 325 X 102MM (29.7 X 12.8 X 4IN) 875-2142A  
Filter Air 85% UF & DF 5/Unit 756 X 325 X 102MM (29.7 X 12.8 X 4IN) 875-2141A  
FIRE DETECTOR  - DOWNFLOW ACAC74493  
FIRE DETECTOR  - UPFLOW ACAC74492  
FLOORSTAND 12" FM35-50 KW W/AIR DEFLECTORS ACFS74121  
FLOORSTAND 15" FM35-50 KW W/AIR DEFLECTORS ACFS74122  
FLOORSTAND 18" FM35-50 KW W/AIR DEFLECTORS ACFS74123  
FLOORSTAND 21" FM35-50 KW W/AIR DEFLECTORS ACFS74124  
FLOORSTAND 24" FM35-50 KW W/AIR DEFLECTORS ACFS74125  
FLOW SW, SPDT 1"MNPT 560-7017 () F61MB-1
FLOW SW, SPDT 1"MNPT 560-7023 F61KB-11
FLTR-DRIER 875-2126  
FM NEW ACFM MODELS - Spare Compressor 40kW, 460-480V W875-3880  
FM NEW ACFM MODELS - Spare Compressor 40kW, 460-480V W875-3881  
FM Spare Compressor 35kW, 230V W875-3274 COMP,SCROLL 208-230/3/60 ZRT108
FM Spare Compressor 35kW, 460V W875-3276 COMP, SCROLL 460/3/60 ZRT108
FM Spare Compressor 35kW, 575V W875-3272 COMP,SCROLL 575/3/60 ZRT108
FM Spare Compressor 40kW, 230V W875-3285 COMP,SCROLL 208-230/3/60 ZRT136
FM Spare Compressor 40kW, 460V W875-3284 COMP,SCROLL 460/3/60 ZRT136
FM Spare Compressor 40kW, 575V W875-3283 COMP,SCROLL 575/3/60 ZRT136
FM Spare Compressor 50kW, 230V W875-3282 COMP,SCROLL 208-230/3/60ZRT188
FM Spare Compressor 50kW, 460V W875-3281 COMP,SCROLL 460/3/60 ZRT188
FM Spare Compressor 50kW, 575V W875-3288 COMP,SCROLL 575/3/60 ZRT188
FUSE BLOCK CLASS CC 3P 30A 600VAC (OPM-NG-SC3) 890-0062  
FUSE CLASS CC 10A 600VAC 516-0078  
FUSE CLASS CC 15A 600VAC 516-0079  
FUSE CLASS CC 20A 600VAC 516-0080  
FUSE CLASS CC 25A 600VAC 516-0081  
FUSE CLASS CC 30A 600VAC 516-0082  
FUSE CLASS CC 3A 600VAC 516-0084  
FUSE CLASS CC 6A 600VAC 516-0083  
HEAT EXCHANGER - FM NAM 35KW GLYCOL R22 870-2822 (0M-74366 Assy) BRAZED PLATE HX WP7M-50
HEAT EXCHANGER - FM NAM 35KW WATER, R22 870-2819 (0M-74342 Assy) BRAZED PLATE HX WP7M-30
HEAT EXCHANGER - FM NAM 40KW GLYCOL R22 870-2823 (0M-74368 Assy) BRAZED PLATE HX WP7M-70
HEAT EXCHANGER - FM NAM 40KW WATER, R22 870-2820 (0M-74367 Assy) BRAZED PLATE HX WP7M-34
HEAT EXCHANGER - FM NAM 50KW GLYCOL R22 870-2824 (0M-74369 Assy) BRAZED PLATE HX WP7M-80
HEAT EXCHANGER - FM NAM 50KW WATER, R22 870-2821 (0M-74343 Assy) BRAZED PLATE HX WP7M-44
HEAT EXCHANGER O-RING 1-3/8" (O-RING) 827-0720  
HEAT EXCHANGER O-RING 7/8 827-0719  
HEAT EXCHANGER S/A COPPER ADAPTER 2-1/4" H/E PIPING 0M-4894  
HEAT EXCHANGER S/A COPPER ADAPTER 2-3/4" H/E PIPING 0M-4895  
Heater Assy 380-410V 9.5 KW 3ELEM 0M-1370B  
Heater Assy 460-480V 9.5 KW 3 ELEM 0M-1368C  
Heater Assy 460V 15.2KW 6-ELEMENT 0M-5821A  
Heater Assy 575-600V 9.5 KW 3ELEM 0M-1366C  
HEATER SCR 3P 2L 240V 40AMP (SCR) 101-0062  
HEATER SCR 3P 2L 480V 40AMP (SCR) 101-0063  
HI-PRESS SW OPENS 375 PSIG Assy (comes with harness) 0M-6919 Assy (540-0101 Switch Only) P100DC-3D  
HTR,CRANKCASE 480V 90W 101-0025  
Humidifier Canister Cleanable 200-230V (BLCT2B00W0) (208V) w491-0473  
Humidifier Canister Cleanable 380-575V (BLCT2D00W0) (460v) w491-0474  
Humidifier Canister Cleanable Low Conductivity 200-230V (BLCT2A00W0) (208) 875-0821  
Humidifier Canister Cleanable Low Conductivity 380-575V (BLCT2C00W0) (460) 875-0849  
Humidifier Canister Replaceable 200-230V (BLOT2B00H0) (208V) w491-0475  
Humidifier Canister Replaceable 380-575V (BLOT2D00H0) (460V) w491-0476  
Humidifier Canister Replaceable Low Conductivity 200-230V (BLOT2A00H0) 875-0850  
Humidifier Canister Replaceable Low Conductivity 380-575V (BLOT2C00H0) (460V) 875-3738  
Humidifier compression fitting 875-0519  
Humidifier Condensate Hose 3/8 ID (Fits over 3/8" OD copper tube on all steam distributors) 660-7003B  
Humidifier CYLINDER HOLDING BELT 875-00029  
Humidifier drain valve (new) color:beige/tan (carel) W875-4257  
Humidifier drain valve (old) color: Black (carel) 875-4232 replaced with W875-4257  
Humidifier fill valve w875-4233  
Humidifier Frame 208-575V -- KUET20AP00 491-0477  
Humidifier Peristolic Pump (requires 24volts in an FM there is a connector ) 491-0510  
Humidifier Peristolic Pump Goo (solution-send with the perostolic pump) 491-0511  
Indoor Receiver 875-5053  
Indoor Receiver Relief Valve 425psig 3/8 MPT X 1/2 FLARE (for outdoor unit) 875-4230  
Key 870-8135  
KIT FM35-50 E-BOX WIRING 0W2677C  
KIT FM35-50 UNIT WIRING DOWNFLOW 0W2678A  
KIT HARDWARE/TOOL FM 0M-5422  
Latch keeper Southco (connects to 840-0081) 840-0080  
Latch Southco (connects to 840-0080) 840-0081  
Lid-Shunt Trip Bezel 870-79683A  
Loss of mains board (Mains Board) W0P4618  
Main Controller Board (NOME Board) W0P4586 (0P4586A)  
MTR ACTR FLOATING W/ FEEDBACK M9116 491-0083 Non-Spring Return
MTR ACTR FLOATING W/ FEEDBACK M9216 491-0082 Spring Return
NMC AP9617  
NTC CAREL TEMP SENSOR [CW temp sensor] W360-0094  
O-RING 1 3/8" Teflon FM units 827-0720  
O-RING 7/8" Teflon FM (heat exhanger) 827-0719  
P66 Controller Single Circuit (dual circuit)P66-AAB-10 391-0027 (391-0028)  
PAD ANTI VIBRATION 6X6X7/8 850-0100  
PCIOM Board W0P4589 (0P4589A)  
Plastic tube (for the T/H/P sensors. PVC 0.125in ID 0.188in OD) 875-0521  
PLENUM, 20" FT//LT, FM 35-50 KW - BLACK ACPL74093  
PLENUM, 20" FT/RT, FM 35-50 KW - BLACK ACPL74092  
PLENUM, 20" FT/RT/LT, FM 35-50 KW - BLACK ACPL74091  
PLENUM, 24" FT, FM 35-50 KW - BLACK ACPL74098  
PLENUM, 24" FT/LT, FM 35-50 KW - BLACK ACPL74097  
PLENUM, 24" FT/RT, FM 35-50 KW - BLACK ACPL74096  
PLENUM, 24" FT/RT/LT, FM 35-50 KW - BLACK ACPL74095  
PLUG 1-1/2 A07437 875-0661  
PowerView Display (single display) wAP9231  
PowerView Label Air (NOME) 885-1577  
PRESSURE RELIEF VALVE - 3/8 MPT X 1/2 FLARE 425 PSIG W875-4230  
QCRAC-MISC-QCC12875-00 (for non-stocked 3rd party parts) Air Miscellaneous Sku  
REACTOR 5% IMP 208-240V 50-60HZ 3HP 420-1000  
REACTOR 5% IMP 400-480V 50-60HZ 3HP 420-1001  
REACTOR 5% IMP208-240V50-60HZ 5HP 420-1003  
REACTOR 5% IMP400-480V50-60HZ 5HP 420-1002  
RECEIVER ASSY & 425 PSIG RELIEF VALVE 0M-3744  
Remote T/H Sensor AP9520TH  
Return/Supply Temperature, Humidity, and Pressure Sensor WAP9520TP  
Rope Water Detector Assembly (0W1586 cable only) ACAC74409  
SEISMIC FLOORSTAND, 12"  FM 35-50 KW W/AIR DEFLECTORS ACFS74131  
SEISMIC FLOORSTAND, 18" FM 35-50 KW W/AIR DEFLECTORS ACFS74132  
SEISMIC FLOORSTAND, 24"  FM 35-50 KW W/AIR DEFLECTORS ACFS74133  
Shunt Trip Bezel (includes lid) 0M-76443A  
SIDE PANEL ASSY, LH UF/RH & LH DF, BLACK 0M-74411C  
SIGHT GLASS 7/8" ODF SOLDER 875-2150  
Smoke Detector Assembly ACAC74491  
SMOKE DETECTOR BASE PHOTOELECTRIC ESL 360-0154  
SMOKE DETECTOR HEAD PHOTOELECTRIC ESL 360-0153  
SMOKE DETECTOR HOUSING 870-79478A  
SOLENOID VALVE REFRIGERATION 3/8 (DEHUM) (FM 875-4196  
SOLENOID VALVE REFRIGERATION 3/8 IN (Dehum) 875-4237  
SOLENOID VALVE REFRIGERATION 5/8 (LL) 451-0182  
SOLENOID VALVE REFRIGERATION 5/8 IN (LL) 875-4238  
Spot Water Detector (Assy. 0M-74243 -- nothing additional just additional cost) 541-0071 (ACAC74415)  
steam hose 660-0071  
SWITCH DOOR (SB1PC10A) (Airblock Interlock Switch) 540-0047  
TAPE, ARMAFLEX INSUL 2X1/8 670-7000  
TELECOUPLNG 8P8C RJ45 STRAIGHT (ethernet telecoupler) W750-0034  
TEMP/HUM/LCD BOARD 0P4588A  
Temperature/Humidity/Pressure Sensor (use WAP9520TP) WAP9520TP  
Terminator (Customer Interface/PCIOM/Supply & Return Temp. Pressure Sensor) 0W04161  
THERMOSTAT TEMP CNTL 25-215F (FIRESTAT) 541-0012  
Touch Up Pait Pen -- Raven Black Paint Pen 690-0108-001  
Tranformer AUTO 3 PHASE 575 X 460 4.0KVA (for Canada) 430-0236  
TRANSDUCER PRESSURE 2CP5 W875-3400  
Transformer (Transformer A, B, & C) W430-0197  
Transformer Swap kit (comes with 3 transformers) 0M-0951(Individual - W430-0197)  
TXV 5/8" X 1 1/8" R22 11 TON 875-1059/875-1057A  
TXV 5/8" X 1-1/8" R22 - (FM NEW ACFM MODELS) W875-1059 875-1058A
TXV 5/8" X 1-1/8" R22 15 TON (FM 50) 875-1058A  
User/Customer Interface Board (where sensors and Cat5e connects) W0P4590  
VALVE 3-WAY 1-1/2 "L" PORT (ValveTeck pn# BVL5X2B270) 875-4384 (replaces 875-4163)  
Adaptor for new 3-way valve 0w3379  
New 3-way valve (includes bracket, acuator, valve, but not plug adaptor) 875-4384  
VALVE 3-WAY 1-1/2 (ZE1644EB+M9511 J.C.) (obselete) 875-4163 (0M-3479 -2way vlve with cap)  
VFD COM E BOX CABLE ASSY FM35-50 0W1537  
VFD MOTOR 3HP 200-240V (6KE1123003X1A1) (evaporator) W491-0079  
VFD MOTOR 3HP 380 - 480V (6KE1143003X1A1) (evaporator) W491-0463  
VFD MOTOR 5HP 200-240V (6KE1123005X1A1) (evaporator) W491-0466  
VFD MOTOR 5HP 380-480V (6KE1143005X1A1) (evaporator) 0J-491-0467A + 0J-0363   
VLV ROTO 1 1/4"; 7/8"SWT 875-4170  
VLV ROTO 1 3/4" 1 1/8"SWT (discharge line for compressor) 875-4173  
VLV ROTO 1 3/4"; 1 3/8"SWT 875-4177A  
VLV ROTO 1 3/4"; 1 3/8"SWT (suction line for compressor) 875-4176  
Water Flow Switch Assy ACAC74412  
WELDMENT FRONT FASCIA 0M-74410D  
WIRE ASSY FM 35-50 AUTOTRANSFORMER 0W1920  
WIRE#24 CAT.5 BLK 1' PATCH (connects PCIOM to User Interface Board) 0W1538  
WIRE#24 CAT.5 BLK 4' PATCH 0W02342  
WIRE#24 CAT.5 BLK 5' PATCH (DF) 0W02343  
WIRE#24 CAT.5 BLK 7' PATCH (DF) 0W1534  
WIRE#24 CAT.5 BLK 7' PATCH (DF) W0W2941  
WIRE#24 CAT.5 BLK 9' PATCH 0W1536  
Wiring Harness for the Smart Slot 10inches 0W0436  
GASKET BLOWER FM SERIES 870-3645A