Clipsal Iconic Family Room Rocker 10 Pack

Clipsal Iconic Family Room Rocker, 10 Pack

Clipsal Iconic Family Room Rocker 10 Pack

Item Number: 40FAR-VW

Retail
$33.55
RRP (Inc. GST)

The Clipsal Iconic Family Dolly Rocker is designed for compatibility with the Clipsal Iconic accessories range to help make your life simpler. In a modern vivid white finish, the dolly rocker looks great in the home.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width23 mm

Height icon

Height23 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

rocker

Physical

Quantity per set

set of 10

Marking

family

Switch function

2 positions

Height

23 mm

Width

23 mm

Depth

9 mm

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

14 g

Package 1 Height

9.17 mm

Package 1 width

20.39 mm

Package 1 Length

23.25 mm
Show all specifications

Frequently Asked Questions

hide show

What is the replacement for a C32L-MA Multi9, Circuit breaker, 40kA, 25A?

The closest replacement for a C32L-MA Multi9, Circuit breaker, 40kA, 25A magnetic only is a 25A, 50kA, a magnetic only unit with the dimensions of 81mm(W) X 103mm(H) X 81mm(D).
The part number for this unit is 18884.
 
This can be found on page 2.1.14 of the 2016 Schneider Product Guide.

Is the Clipal 30FAV a solder connector

They are F connectors on the back.  Clipsal do not do solder on the back of RCA's

Can the 30FAV Red and White be purchased as individual parts

No they come in the pack of 30FAVRWY so red, white and yellow combination

What does Neg stand for under logic inputs in SFT2841?

Product Line  
SEPAM 20
SEPAM 40
SEPAM 50
SEPAM 80

Resolution   
There is a Neg box for the logic inputs in SFT2841. This option, if checked, allows one to wire the input as a negative input. For instance, 1 is normally considered to be high, if you checked Neg, you would effectively be telling the relay that 0 is high.

 

SEPAM Series 40 and 50 Wiring Diagram

Issue  
Need the wiring diagram for the SEPAM 40 and 50.

Product Line   
SEPAM Series 40
SEPAM Series 50


Resolution   
Attached is the wiring diagram for the all SEPAM Series 40 and 50.

Cutout diagram for the SEPAM 40 and 50.

Issue  
Need the cutout diagram for the SEPAM 40 and 50.

Product Line   
SEPAM Series 40
SEPAM Series 50


Resolution   
Attached is the cutout diagram for the all SEPAM Series 40 and 50.
 

3090SCCT Frequently Asked Questions

Product Line
3090SCCT

Environment
Current Transformer

Resolution
What is the minimum load require for accurate readings?
A load of 10% of the max load is required in order to saturate the CT.

For example, a 3090SCCT124 with a 1200A maximum requires a 120A load to be accurate.

Note:Technical support will not troubleshoot loads below 10%.

Is there a 3090SCCT smaller than 200:5?
No. If more accuracy is required please see FA212449 for Solid Core CTs.

Which wire is the positive and negative for the 3090SCCT?
X1, S1, or H1 is the positive wire.
X2, S2, or H2 is the negative wire.

Schneider Electric model SCCT current transformers identify the X1 wire as WHITE and the X2 wire as BLACK.


See FA212245 for all of the wiring standards of the 3090SCCT.

Where can the 3090SCCT cut sheet be found?
The cut sheet for 3090SCCT can be found in FA212730.

Can the leads be extend on the 3090SCCT?
Yes. Please see FA212841.

Are 3090SCCTs sold individually or in sets?
Individually. 

Are the 3090SCCT series current transformers rated for outdoor use?
No. Please see FA212946.

What is the part number for the 3090SCCT?
Part Number Description
3090SCCT022 SPLIT-CORE CT, 200A, 1.25" X 1.51" ID
3090SCCT032 SPLIT-CORE CT, 300A, 1.25" X 1.51" ID
3090SCCT043 SPLIT-CORE CT, 400A, 2.45" X 2.89" ID
3090SCCT063 SPLIT-CORE CT, 600A, 2.45" X 2.89" ID
3090SCCT083 SPLIT-CORE CT, 800A, 2.45" X 2.89"ID
3090SCCT084 SPLIT-CORE CT, 800A, 2.45" X 5.50" ID
3090SCCT124 SPLIT-CORE CT, 1200A, 2.45" X 5.50" ID
3090SCCT164 SPLIT-CORE CT, 1600A, 2.45" X 5.50" ID
3090SCCT204 SPLIT-CORE CT, 2000A, 2.45" X 5.50" ID
3090SCCT244 SPLIT-CORE CT, 2400A, 2.45"X5.50" ID

Notes:
  1. For split-core CTs rated for 2400A to 6000A, please refer to FA359622
  2. For quotes, please contact inside sales at 615-538-3845.

How long does it take the digital input for logic discrimination (ZSI) to be recognized by the Sepam relay?

Issue
User wishes to know how long it takes the digital input for ZSI to be recognized by Sepam relay

Product Line
Sepam series 20
Sepam series 40
Sepam series 80

Environment
Performance

Resolution
It takes approximately 13 ms (one cycle time of the control reading) operating time for the relay to recognize and react to an input change.

Note: For a Sepam series 20, only input I13 can be used to receive a blocking reception.

Unable to access PowerChute Business Edition or PowerChute Network Shutdown web interface with default browser using localhost as the IP address

Issue:
Unable to access PowerChute Business Edition or PowerChute Network Shutdown web interface with default browser using localhost as the IP address
Example: https://localhost:6547

Products:
PowerChute Business Edition web Agent all version
PowerChute Network Shutdown web client all version

Environment:
Linux OS running Mozilla Firefox versions 37, 38, 39, 40

Cause:
https://bugzilla.mozilla.org/show_bug.cgi?id=1148766

Solution:
Upgrade Mozzilla Firefox to version 51.or access the web interface using https://<system IP>:6547 
Examples: https://192.168.1.10:6547



 

SFT2841 Setting and Operation Software Overview

Issue  
Need an overview of the SFT2841 software for the SEPAM relay.

Product Line   
SFT2841
SEPAM 20
SEPAM 40
SEPAM 80


Resolution   
The SFT2841 software is the setting and operating tool for SEPAM series 20, SEPAM series 40 et SEPAM series 80. It may be used in 2 operating modes:
  •  unconnected to SEPAM, to prepare parameter and protection settings
  •  connected to SEPAM, to download and upload SEPAM parameter and protection settings and have access to all operating functions.
Please see attachment for more information.

Input Circuit Breaker Requirements for Symmetra PX 20/40/80 kw


Issue:
This document describes the required input over current protection (circuit breaker) required when installing a Symmetra PX

 
Product line:
Symmetra PX1 Products


Environment:

All models/ all serial numbers

Cause:
Input Circuit Breaker Requirements for Symmetra PX 20/40/80 kw

Resolution:
ISX 20K (All-in-One)
90A 208vac

Symmetra PX 40
175A 208vac
80A 480vac (PDU w/ Step Down Transformer required)
60A 600vac (PDU w/ Step Down Transformer required)

Symmetra PX 80
350A 208vac
150A 480vac (PDU w/ Step Down Transformer required)
125A 600vac (PDU w/ Step Down Transformer required)


For more information about this subject please refer to Application Notes 148, 149, and  150. (APC Symmetra PX Frame Installation Deviation and Selection of Input Circuit Breaker Ratings)

App note 150
https://www.apc.com/salestools/AWAR-7KEP2T/AWAR-7KEP2T_R0_EN.pdf
 
App note 149
https://www.apc.com/salestools/AWAR-7KEPUW/AWAR-7KEPUW_R0_EN.pdf
 
App note 148
https://www.apc.com/salestools/AWAR-7KEQPR/AWAR-7KEQPR_R0_EN.pdf

Application of SEPAM Relays for Arc Flash Hazard Reduction at LOW_VOLTAGE Switchgear

Issue  
Need to limit the ARC flash hazard using the SEPAM relay.

Product Line
SEPAM 20
SEPAM 40
SEPAM 80

Resolution
This report documents application of the SEPAM protective relay for reduction of arc flash hazard levels at LOW_VOLTAGE switchgear not equipped with a main breaker. A common configuration for an industrial electric distribution system is to supply unit substation transformers from a primary distribution system consisting of one or more 15 kV class switchgear assemblies with feeder breakers and medium voltage cable. Each primary distribution feeder supplies one or more unit substation transformers and associated LOW_VOLTAGE switchgear. The LOW_VOLTAGE switchgear may or may not be equipped with a main breaker. For switchgear not equipped with a main breaker, a protective relay can be applied as a virtual main to sense total current at the LOW_VOLTAGE bus and provide a trip signal to the medium voltage feeder breaker supplying the unit substation. If the virtual main relay can trip the medium voltage breaker with minimal time delay, significant reduction in the arc flash incident energy and hazard level at the LOW_VOLTAGE switchgear can be obtained.

 

Show More