SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN

Decorative SurRound 2 Gang HORIZONTAL Saturn

Catalogue Number: 4000H2
SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN
SURROUND 2 GANG HORIZONTAL SATURN
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Saturn Series 4000
Product brand
Clipsal
Mounting position
horizontal
Sustainable offer status
Green Premium product
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure
ENVPEP120506EN

Frequently Asked Questions

hide show

What is the mounting frame for the 4025H2

 Part code is 4000H2

What is the Cut-Out, Dimensions and/ or Template for a 4000VH2 quad surround?

Please see the below image for the Dimensions and/ or Template for a 4025H2 quad outlet.

How do I scale 0 - 4095 to 6400 - 32000 using 984 Ladder Logic?

The following network scales data from 0-4095 to 6400 - 32,000 when 4-20ma (6400 = 4 mA, 32,000 = 20 mA) outputs are required
but a 0-20ma analog output is used. .





Register 400001 and 400002 are used together in the top node of the EMTH Block, where 400001 is
always 0000 data and 400002 is the variable data, 0-4095, to be scaled. Register 400003, displayed in data
format float, is a fixed floating point value that the user enters as 6.25153 (note that two registers are
used to create the floating point value, 400003 & 400004 in this example). Register 400005 (and 400006)
is the floating point result of the integer and floating point multiplication (EMTH block).





The FTOI (Floating Point TO Integer) block converts the floating point result of registers 400005
and 400006 to an integer value in a single register 400007.

The AD16 block adds the top node register 400007 to the middle node constant 6400 and places
the result in register 400009. This register will then map to one of the analog outputs.

The following data screens shows the input values of 0 and 4095 and there corresponding results.





Is there a decorative surround for the 4025H2 quad outlet?

Yes the part number for a decorative surround for the 4025H2 quad outlet is a 4000H2.

How do I scale data from 0-32,000 to 0-4095 using 984 Ladder Logic?

 

The following network scales data from 0-32,000 to 0-4095 for use with analog signals.





 
Register 300001 contains the analog input data (0-32,000).

This data gets BLKM (Block Moved) to register 400002. 

Registers 400001 and 400002 are the top integer nodes of an EMTH (Divide Integer by Floating point) which is divided by registers 400003 and 400004 (display 400003 as data type float), the middle node registers that contain the floating point constant (7.814408).  

The floating point result is found in registers 400005 and 400006 that is then converted by the FTOI
(Floating point TO Integer) Block to register 400007.

Starting Register number in Modbus Read functions

Goals and Symptoms

When performing Modbus read commands, it is important to apply the right starting register address in the read function. Otherwise, the wrong register will be accessed from the meter, giving unexpected data for the meter parameter being read.


  • Meter is functioning as expected. The front panel values for voltages and currents are within expected ranges for the system being monitored. However, modbus read functions from a master station (e.g. a PLC) give values that do not correspond to the front panel values.

Facts and Changes

Modbus, modbus rtu, function read, modbus map, holding register, staring register, function 03, modbus read packet

Causes and Fixes

Cause
One probable cause would be that, the modbus function read command is not pointing to the right registers. The modbus protocol requires an offset to be introduced in the starting register address when reading the slaves register.

Resolution

When reading the meter parameters, the Master must send the device a Read Holding Registers packet. This packet must specify a start register and the number of registers to read. When the function read is received, the slave responds with a packet containing the registers in the range defined in the read request.

However, consider the 3710 Modbus map, which states that according to the MODBUS protocol, in response to a request for address 4xxxx, the master reads register xxxx-1 from the slave (3710). For example, a request for register 40011 returns register 10 from the slave.

What does the above statement mean? Why is an offset required?

Holding registers, by default, are defined the 4xxxx range, the first holding register staring at 40001. The starting register in the read packet is, on the other hand, numbered from zero. Hence, the start register zero automatically points to holding register 40001, starting register one points to holding register 40002, etc. The fact that the first holding register is 40001 and not 40000 explains the offset that needs to be introduced in the starting register number.

Hence, considering the 3710 Modbus Map statement, if the Master needs to read register 40011, then the corresponding starting register that needs to be put in the read function would be 10 (0A hex) since register 40011 is the register 10 from the first holding register, 40001:
40001 > Start register 0
40002 > Start register 1
40003 > Start register 2
40004 > Start register 3
40005 > Start register 4
40006 > Start register 5
40007 > Start register 6
40008 > Start register 7
40009 > Start register 8
40010 > Start register 9
40011 > Start register 10

The Modbus Read Request Packet for a master reading 3 registers from a slave with unit ID 100 (64 Hex) and for starting register of 40011 should be:
 

Slave ID
Function
Start Register (40011)
# of Registers
CRC Checksum
64
03
00
0A
00032C3C


To summarize, when looking at a modbus map, the starting register number to be used in the read function:

Start Register = Modbus Register 40001.

 

Original article#12774

Public

All content © 1992-2007 Schneider Electric


Legacy KB System (APS) Data: RESL188799 V1.0, Originally authored by KBAdPM on 11/03/2007, Last Edited by KBAdPM on 11/03/2007
Related ranges: Modbus / JBus

Can you get a plate larger than 6 gang in the 2000 series?

Not directly, but using the 2000/2 or 2000h2 series you can fit 2 plates under one surround.

What are the dimension for the 2000H2?

The dimension for the 2000H2 are - H232mm x W 76mm x D13mm

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2000H2
User-added image

When using Concept, what may cause a 4000h Stop Code on my Momentum I/O Bus CPU?

The 4000h stop code may be generated by a bad I/O map, extended memory error or missing loadable. This error will also occur when a Momentum I/OBus network has a third party Interbus device on the network but undefined. The Concept ModConnect tool must be used to generate a MDC file that will define the module and allow the Concept database to insert this definition in the I/O map configuration. A common symptom of this problem is the program will download and start with no problems with an older computer that has the MDC definitions installed. When the project is moved to another computer without the modules MDC file, the project will report a 4000h error after download/ start. To eliminate this error generate a new MDC file using the Concept Modconnect tool.


Can I tell what the Modbus Plus address of my Modicon PLC is via 984 ladder logic?

Yes, the contents of the address configured in node 2 of the MSTR Instruction Function Code #3 (Get Local Statistics) will give you the Modbus Plus Network address of the PLC.
Below is a example of a MSTR Instruction using Function Code #3 (Get Local Statistics) to get the Modbus Plus address of the PLC

400001 = 3 (Operation Type)
400003 = 1 (length)
400004 = 2 (Offset)
400010 = 2 (Network address of this station)

How can a floating point value be moved into 4XXXX registers in a Quantum PLC with 984 LL?


A floating point value can be moved into 4XXXX registers with the equation network. An example of moving a floating point value of 123.456 into registers 40001 and 40002 is shown below:

 

Do the 4000PP suit both the Saturn and Saturn Zen ranges?

Yes, the 4000PP will cover bother ranges.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=4000PP

Show More