switch surface 2way 4term

Flush Switches, Surface Switches, 250V 10A - 2 Way, 4 Terminal

Catalogue Number: 363
switch surface 2way 4term
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Device presentation
basic element
Switch function
2-way
Control type
toggle
Device mounting
surface
Fixing mode
by screws
Local signalling
without
[Ue] rated operational voltage
250 V AC
Rated current
10 A
Marking
without marking
EU RoHS Directive
Compliant
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

  • Corporate Marketing

Frequently Asked Questions

hide show

My smartlink does not recognize my PowerTag A9 P63 & A9 F63 - what should I do?

The new PowerTag A9 P63 & A9 F63 are supported by Smartlink Firmware from version V 2.2.0 + Ecoreach version V2.7.X
Update your Smartlink and Ecoreach version using Ecoreach software 

Is part number 343 available as 2 way?

Yes. Part number 343 is standard as 2 way.

I am looking for a replacement Goldair Heater

We are no longer agents for the Goldair range.  You can contact SSM (Specialised Sales & Marketing) 0800 963 963

Is there an alternative for SS165/15/2?

There is no direct replacement for the SS165/15/2
The closest product to the SS165/5/2 is the 362 and 363 series of surface switches

For more information please visit the Clipsal web site on the links provided .
https://www.clipsal.com/Trade/search-results?q=362
https://www.clipsal.com/Trade/search-results?q=363

How do I dispose / recycle APC batteries?

Phone 0800 333 373 APC technical team in the Phillipines or go to the website: recycle.apcpacific.com/nz
 

For PowerTag A9 P63 & F63 (1P + N), how to fasten the current measurement module so that it does not freely move in the cabinet ?

One possible solution would be to stick an adhesive cable tie mount to the side of the PowerTag and attach the cable tie to the neutral power wire.

Is the Clipsal 343 a 2 way switch

This is a two way switch

What is the overall dimension of 651A2-BK?

Overall dimension of 651A2-BK is 365 (W) x 209 (H) x138(D).

For PowerTag A9 P63 & F63, do I have to fasten the current sensor on the power cable?

It's not necessary.

Is there a mounting ring for the 343 pull switch?

No, unfortunately there is nothing available.

I see that PowerTag A9 P63, M63 are said to be compatible only with Schneider Electric products included in the selection guide (CA908058). Can I mount it on different brand products?

Schneider Electric has carried out tests for heating and mechanical compatibility with the products covered by the selection guide (CA908058).Schneider Electric is not able to conduct these tests for all products on the market.
The other possibility is to use the PowerTag A9 F63 version while ensuring the compatibility of the electrical connection. 

Are the ATV Process drives (ATV630, ATV650, ATV930, ATV950) conformal coated?  What about the ATV320 and ATV340?

Issue: 
Are the ATV Process and ATV Machine drives conformal coated? 

Product Line:
ALTIVAR 630
ALTIVAR 650
ALTIVAR 930
ALTIVAR 950
ALTIVAR 320
ALTIVAR 340

Environment:
All
 
Cause:
N/A

Resolution:
Altivar Process (ATV6x0 and ATV9x) withstand to harsh environments:
- Chemical class 3C3 conforming to IEC/EN 60721-3-3.
- Mechanical class 3S3 conforming to IEC/EN 60721-3-3.
Except:
- Altivar Process ATV630C22...C31N4 drives are certified as chemical class 3C2 and mechanical class 3S2 conforming to IEC/EN 60721.
- Altivar Process ATV930C22...C31N4 drives are certified as chemical class 3C2 and mechanical class 3S2 conforming to IEC/EN 60721.

Altivar Machine (ATV320 and ATV340) withstand to harsh environments:
- Chemical class 3C3 conforming to IEC/EN 60721-3-3.
- Mechanical class 3S2 conforming to IEC/EN 60721-3-3.

However, in all cases, there are no published certificates that we can send out. 

What is the impact on energy measurement (kWh) if I mount the PowerTag A9 F63 Power Module upside down?

No impact on energy measurement

Need a 360 degree PIR low voltage occupancy sensor

 Use a SAE_UE_MS_CSAWE.

Why does the system type in an Enercept Meter not change when writing to register 36?

Product Range
Enercept Meter

Environment
Setup

Resolution
You must choose the register type to be Single Holding Register (R03 / W06).

What is the part code for a 700VA Fan speed controller?

We do not have a 700VA Fan speed controller.

What is the warranty period for TPLP1 and TPLP2, 36W LED panel lights?

TPLP1 and TPLP2 is guaranteed against faulty workmanship and materials for a period of three (3) years for the LED panel and three (3) years for the LED driver, from the date of installation.
For further information on the product please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=TPLP1
https://www.clipsal.com/Trade/Products/ProductDetail?catno=TPLP2


 

What justifies the choice of the PowerTag A9 F63 blade terminals?

The blade terminal of the PowerTag A9 F63 has been designed so that it does not generate any mechanical interference with the power wire, regardless of the type of cable (flexible / rigid) and the preparation of its end (bare / insulated crimped cable end / non-insulated crimped cable end). This blade terminal can not be considered as a crimped cable end, but it should be considered as a specifically designed electrical connection in the same way as: the connection terminals of a PowerTag M63 or P63, or the tooth of a distribution comb. When connecting the power wire to a screw terminal in accordance with the recommendations given in the installation instructions (cable type, section, stripping length, type of preparation, tightening torque, correct alignment between blade terminal and power wire), no degradation is generated by the PowerTag Flex blade terminal on the mechanical withstand and the quality of the cable connection.

What is part number for occupancy sensor 360 degrees ultrasonic?

The part number for occupancy sensor 360 degrees ultrasonic 752/CD1RC.

For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=752/CD1RC


User-added image

Do you have a BT connector E.g. 563 but for 35mm with 3 screws?

No, however we do have a connector that suits up to 2x 35mm2 cables with two screws. The part number is 563K35.

Some of the key features are:
  • 2 cables
  • Clear insulated
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=563K35.
 

Is Microsoft Office 365 supported with PME 8.x?

Issue:
A customer would like to know if PME 8.x is compatible with MS Office 365.

Product Line:
PME 8.x

Environment:
Software Compatibility

Resolution:
Currently PME 8.x supports Excel 2016 which is part of Office 365. This is strictly in the sense that Excel 2016 is installed locally on the server or engineering client in order to run reports.  The cloud based components of 365 are not supported.

What are the dimensions for a PDL Thermosafe heater?

PDL no longer supplies the Thermosafe range, or any heating appliances.

255 x 362 is the cutout size for the flush mount box.
See attached pdf for more.

 

Do you sell a Y piece with conduit entries?

Yes 263 series of conduit fittings has a Y shape fitting.
263Y20
please see link below for more details
https://www.clipsal.com/Trade/Products/ProductDetail?catno=263Y20
 

What does the "383" suffix represent on and ATV71....N4383 ?

Issue:
What does the "383" suffix represent on and ATV71....N4383 ?

Product Line:
ATV71

Environment:
ATV 71H075N4…HD75N4

Cause:
Non

Resolution:
Variable speed drive for synchronous motor with speed feedback
The drives are supplied as standard for asynchronous motors with or without sensor feedback.
ATV 71H075N4…HD75N4 drives can control not only those motors included in the standard offer, but also synchronous motors with speed feedback, by adding 383 at the end of the reference.
Example: ATV 71H075N4 becomes ATV 71H075N4383.
See available encoder interface cards.

What is the 600 series unit that will fit on to a 125ml modempak ducting

Need to contact Modempak for confirmation (ph - 0800 663 367) but in theory if the mounting clip for the ducting has 84mm
centres it should fit the PDL 600 Series

Timeout behavior of 140 DDO 364 00

Goals and Symptoms

The purpose of this resolution is to inform the user about an unexpected Timeout behavior of the Quantum Output module 140 DDO 364 00.

Facts and Changes

Quantum Output modules default in case of Timeout of communication to a PLC in general is Set to Zero.
Due to an incorrect default parameter of the 140 DDO 364 00, the Timeout behavior is Hold Last Value.

Affected Concept versions: Concept 2.2
Concept 2.5SR1
Concept 2.5SR2
Concept 2.6SR1


To change the Timeout behavior, the user has to open the Module Parameter screen and has to leave it by the OK button. To leave it by the Cancel button will not change the Timeout behavior.
 

Causes and Fixes

The Timeout default will be corrected with Concept 2.6SR2


Legacy KB System (APS) Data: RESL161741 V1.0, Originally authored by on , Last Edited by on
Related ranges: Concept

What is the part number for a 36W Battern light?

The part numbers for the 36W battern are BB136NEL for a 1x36W bare battern,BB236NEL for a 2x36W bare battern, DB136NEL for a 2x36W diffused battern and DB236NEL for a 2x36W diffused battern.

Some of the key features are:
  • Electronic batterns and T-bar
  • Reliable and energy-efficient lighting
  • Polycarbonate end caps and lamp holders
  • Weatherproof versions formed in Polycarbonate base and diffuser
  • Colour 840 lamps included
  • DALI control options available
  • Range of reflectors and wire guards to suit
  • End-to-end mounting possible with pre-formed cable entry punch-outs
  • Large terminal blocks for looping applications

For further information please visit https://www.clipsal.com/Trade/Products/Lighting
 

Are the process drives treated for increased protection for dusty and corrosive environments?

Issue:
Replacement for the S337 option.

Product Line:
ATV630 and ATV930

Environment:
All models and serial numbers

Cause:
None

Resolution:
All Altivar Process drives have the higher rated 3C3 rating as standard.  This replaces the S337 option on the ATV61 and ATV71 drives.

What is the part number for dual tech , dual load 360 degree occupancy sensor?

The part number for the dual tech dual load 360 degree occupancy sensor is - 752/CD2RC
For further information about the above sensor , go to link below:
https://www.clipsal.com/Trade/search-results?q=752/CD2RC

User-added image

What is the part number for the 360 degree flush mount infrascan?

The part number for the 360 degree flush mount infrascan are
753 .... its a 2 wire device
https://www.clipsal.com/Trade/Products/ProductDetail?catno=753

753R ... its a 3 wire device
https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R

User-added image
 

What is the part number for a 360 degree infrascan for internal use ?

The part number for a 360 degree infrascan for internal use is - 753R

For further information , visity link below:-
https://www.clipsal.com/Trade/search-results?q=753R

User-added image

What is the part name for the standalone C-Bus power supply?

The part name for the standalone C-Bus power supply is 5500PS

This power supply should only be used to power C-Bus hardware, and provides up to 350mA at 36v DC

Note, this power supply is not suitable for use with the CTC series touchscreens, these units have their own power supplies

Is there a 360 degree sensor with a fluro lighting rating

The SAE_UE_MS_CDB has a fluro rating of 900VA/100uf compensated

Is there a 360 degree infrascan for C-Bus?

Yes, the part name is 5753PEIRL

Which indoor 360 degree sensor can have more than one unit controlling the same load/light?

753R-WE

Can multiple 753R 360 degree sensors be used on the same circuit?

Yes they can providing they are the 3 wire design.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=753R

Do you do a 753R 360 degree sensor that has a timer of 1 hour?

No, unfortunatley this part is no longer available and we have no direct alternative.

For further information please visit https://www.clipsal.com/Trade/search-results/sensor.

What is part no for surface mount 360 degree Infrascan

Part no 753SSR

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=753SSR

User-added image

Can you get an Altistart ATS46 softstart with full voltage bypass?

Issue: Can you get an Altistart ATS46 softstart with full voltage bypass?
 
Product Line: ATS46 8638 8639
 
Environment: Enclosed ATS46
 
Cause: N/A
 
Resolution: It is available with some enclosed units as an option.

With 8638 (Fusible disconnect) units or 8639 (Circuit breaker disconnect) enclosed soft starters the full voltage bypass is option Z24

This option is NOT available with 8636 (non-combination) type enclosed units.

 

Does the W870-8135 NetShelter key work on the combination handle AR8132A?

Issue: 
A customer claims that their new AR8132A door handles can be opened with the standard NetShelter 333 key: W870-8135. 

Product Line: 
NetShelter SX, AR8132A

Environment: 
All models, all serial numbers. 

Cause: 
The AR8132A uses a different key, but the standard 333 key will also open the lock. 

Resolution: 
The AR8132A will accept any key similar when the combination is set to the factory default of 000. 
Once a new combination is set, only the key included with the AR8132A will open the lock. 

Is there a 20A version of a 343 pull cord ceiling switch?

No, unfortunately we do not offer a 20A version. However we do offer a 15A version which is the closest alternative. The part number is 306-*.
* = Colour code E.g. 306-BR is brown.
 

What are the letters marked on the front of the product (X, Y, Z) and on the voltage measurement cable of the PowerTag A9 F63 used for?

The letters are used to make the correspondence between the measurement of the current sensors and the voltage measurements.

I believe someone has hacked my Wiser Link system, what do I do?

If you have any doubt regarding the integrity of your system, contact Schneider Electric Customer Care Center on 1300 369 233

If I face an issue during installation and commissioning whom should I contact?

Contact :partner.supportau@schneider-electric.com
CUSTOMER SERVICE 1300 369 233 (7:30AM TO 7:00PM (MON TO FRI) AEST)
TECHNICAL SUPPORT 1300 202 525 (7:30 AM to 7:00 PM MON TO FRI AEST)

For further information please visit Trade - Clipsal by Schneider Electric

Is there a MSDS for 157FSM?

Yes, the material safety data sheet for the 157FSM Flexible Fire Resistant Sealant is available on request only.
To receive a copy, please call the Clipsal Technical Department on 1300 369 233.

What is the part number for a 360 degree sensor that can have lighting controlled by a LUX level setting?

The part number for a 360 degree sensor that can have lighting controlled by a LUX level setting is - 752/CD1RC
For further information , visit link below:
https://www.clipsal.com/Trade/search-results?q=752/CD1RC
User-added image

What is the right way to connect and chain the MET 148, MSA 141, and DSM 303 accessories on the Sepam 20 or 40?

Goals and Symptoms

What is the right way to connect and chain the MET 148, MSA 141, and DSM 303 accessories on the Sepam 20 or 40?

Causes and Fixes


On the D Port you have to connect and chain in order:

(1) MSA 141

(2) MET 148 ( Attention: Option 2 MET 148 for Sepam 40 only )

(3) DSM 303 (Always at the end of this chain and only if no more than 2 accessories already connected on Sepam)

Note: you can't connect more 3 accessories on this chain so if you already have 1 MSA 141 and 2 MET 148 it is impossible to set also 1 DSM 303. In this case if you want to put this DSM 303, you have to remove the MSA 141 or 1 MET 148.

Key words and phrases: MSA141, MET148, DSM303

AEDL3


Legacy KB System (APS) Data: RESL201098 V1.0, Originally authored by DaMi on 01/22/2010, Last Edited by DaMi on 01/22/2010
Related ranges: Sepam accessories, Sepam series 20, Sepam series 40

Apple Support for NetBotz Appliances

Issue:
Apple Support for NetBotz Appliances

Product Line:
NetBotz

Environment:
Any version

Cause:
Operating system compatibility.

Resolution:
The NetBotz Advanced View (and NetBotz Central Console) do not work with the Apple Macintosh Platform.

The Basic View which is pure HTML should work fine on Apple platforms.
 

What modules support the 140 XSM00200 16 point discrete simulator module connector?

The simulator module connector is designed to operate with the 140DAI 540 00 and the 140 DAI 740 00 modules. These modules are 115 and 230 volts AC and field wire in the same manner. If the power source was reduced to 30volts or less AC the module 140DAI 353 00 could also be used for simulating discrete inputs.


What is the code for an indoors PIR sensor , 360 degrees , that can be wired in parallel.?

Code = 753-WE or 753R-WE
Show More