screw 175 bugle jar 7x45mm

General Accessories Screws, Bugle Head, Self Drilling Point, 7 X 45Mm, Jar 175

Catalogue Number: 357/45J
screw 175 bugle jar 7x45mm
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Material
steel
Surface treatment
zinc plated
Screw gauge
7g
Length
45 mm
Shape of screw head
  • pozidriv No 2
  • bugle head
    • Screwdriver shape
      Philips
      Screw type
      self drilling
      Size of screw head
      9 mm
      Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP060307EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the part number for the bitsa box?

      The part number for the bitsa box is 357TB.
      Some of the key features are:
      • Tool boxes
      • 12 compartment transparent box with assorted screws, screws and quantities included
      • Includes: 357WF30 (100), 357/20 (150), 357WH12 (350), 357P30 (200), 357P20 (300), 357WH25 (100), 357PH50 (50), 357/63 (50), 357WHP32 (100), 357PH45 (100), 357/35 (100), 357/40 (100)
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=357TB


       

      NetBotz Room Monitor 355/455 POE Power Specifications

      Issue:

      NetBotz Room Monitor 355/455 POE Power Specifications

      Product Line:

      NetBotz

      Environment:

      NetBotz Version 3 using POE

      Cause:

      POE specifications

      Resolution:

      The NetBotz 355 and 455 are Class 0 POE devices.

      The IEEE standard 802.3 for supplying power over Ethernet allows the device providing power to use a voltage between 36–57 V DC. The nominal voltage is 48 V with a current of 10–400 mA, subject to a maximum load power of 15.40 Watts.
       

      NetBotz v3 | Serial connection issues

      Issue:
      Issues connecting serially to a v3 NetBotz appliance.

      Product Line:
      NetBotz v3 Wall Appliance: 355/356 (NBWL0355/6) & 455/456 (NBWL0455/6)
      NetBotz v3 Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)

      Environment:
      NetBotz v3 (all versions)

      Cause:
      NetBotz version 3 appliances have integrated USB to serial adapters to allow connecting to the appliance using a USB-A to USB-B cable.  The USB connection to the appliance may not work properly without installing the required FTDI serial driver first.

      Resolution:

      Download and Install the driver from FTDI
      Issues with USB 3.0 Ports from some manufacturers
       
      Download and Install the driver from FTDI

      1) Navigate to https://www.ftdichip.com/Drivers/VCP.htm
      2) Download the driver as a setup executable.


      3) Once downloaded run the setup executable to install the necessary drivers.
      4) The USB cable may need to be unplugged and plugged back in to establish the proper serial connection.
      5) There should now be an entry for a USB Serial communication port under Ports (COM & LPT).
       
      Issues with Windows 7 USB 3.0 ports with FTDI driver

      After installing the correct driver, the NetBotz Appliance may still show as an unknown device within the device manager when using a USB 3.0 port on a Windows 7 system.  To allow the driver to work properly, connect to the appliance using a USB 2.0 port. More information about the issue can be found on the FTDI site here:
      https://www.ftdichip.com/Support/Documents/TechnicalNotes/TN_152_USB_3.0_Compatibility_Issues_Explained.pdf
       

      NetBotz v3 | How do I enable/disable SNMP?

      Issue:
      Issues connecting serially to a v3 NetBotz appliance.

      Product Line:
      NetBotz v3 Wall Appliance: 355/356 (NBWL0355/6) & 455/456 (NBWL0455/6)
      NetBotz v3 Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)

      Environment:
      NetBotz v3 (all versions)
      NetBotz v2 (all verisons)

      Resolution:

      Enable SNMP on a v3 NetBotz Appliance

      1) Download and install the Advanced View Application.  Instructions for download can be found in knowledge base FA230223.
      NOTE: If Advanced View is already installed, skip step 1.

      2) Log into your NetBotz appliance as an administrator using the Advanced View application.

      3) Select the Configuration tab and then under Appliance Settings navigate into SNMP.

      4) Check the box for Enable SNMP agent.

      5) Fill out the information within Version 1/Version 2c or Version 3 tabs.
      NOTE: SNMPv3 settings are based on user profiles.  For user profile configuration see knowledge base FA323442.

      6) Select OK to save the settings.


      Disabling SNMP 

      1) Download and install the Advanced View Application.  Instructions for download can be found in knowledge base FA230223.
      NOTE: If Advanced View is already installed, skip step 1.

      2) Log into your NetBotz appliance as an administrator using the Advanced View application.

      3) Select the Configuration tab and then under Appliance Settings navigate into SNMP.

      4) Uncheck the box for Enable SNMP agent.
      NOTE: Specific SNMP portocol versions can not be individually enabled/disabled.  SNMP is either enabled/disabled as a whole protocol.

      6) Select OK to save the settings.

      NetBotz v3 | Can an Advanced Software Pack be transferred to a different NetBotz appliance?

      Issue:
      Can an Advanced Software Pack be transferred to a different NetBotz Appliance?

      Product Line:
      NetBotz v3 Wall Appliance: 455/456 (NBWL0455/6)
      NetBotz v3 Rack Appliance: 450/451 (NBRK0450/1)

      Environment:
      NetBotz v3 (all versions)

      Cause:
      A new NetBotz appliance was purchased and the old one had an Advanced Software Pack associted to it.

      Resolution:

      The Advanced Software Pack License is tied to the first NetBotz unit it is assigned to.  It cannot be transferred.  For each new NetBotz unit purchased, an Advanced Software Pack License will also need to be purchased. 

      NOTE: If the NetBotz Appliance was replaced by technical support due to hardware failure, a replacement Advanced Software Pack can be associated to the replacement appliance.

      NetBotz v3 | Camera POD 160A appears to not function properly

      Issue:
      Why does the Camera POD 160A appear to not work with the NetBotz appliance it is connected to?

      Product Line:
      NetBotz v3 Wall Appliance: 455/456 (NBWL0455/6)
      NetBotz v3 Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)
      NetBotz v3 Accessories: Camera POD 160A (NBPD0160A)

      Environment:
      NetBotz v3 (firmware below 4.6.2)
      NetBotz Camera POD 160A

      Cause:
      Newer NetBotz Camera Pods (NBPD0160A) are running a hardware revision that are not compatible with older NetBotz firmware. This causes the camera to appear failed and not register on the main NetBotz unit. 

      Resolution:

      Updating the NetBotz appliance to firmware version 4.6.2 or later will correct the problem.  If you have upgraded or are already running 4.6.2 or later and are still experiencing difficulties, contact technical support.
      Please note that this could also happen on a NetBotz 355A or 455A with the on-board camera with firmware prior to 4.6.2..

      Verifying NetBotz Appliance Firmware Revision

      1) Log into the NetBotz appliance using the Advanced View application.
      NOTE: For instructions on downloading Advanced View, see knowledge base FA230223.

      2) Select the About tab.

      3) The firmware revision will be listed in the Bootstrap Version field.


      Upgrade NetBotz Appliance Firmware

      Instructions on upgrading a NetBotz appliance firmware can be found within knowledge base FA158254.

       

      NetBotz v3 | How do I manage user credentials and login alerting?

      Issue:
      Process for configuring user credentials and login alerting on a version 3 NetBotz appliance.

      Product Line:
      NetBotz v3 Wall Appliance: 355/356 (NBWL0355/6) & 455/456 (NBWL0455/6)
      NetBotz v3 Rack Appliance: 450/451 (NBRK0450/1), 550 (NBRK0550), & 570 (NBRK0570)

      Environment:
      NetBotz v3 (all versions)

      Resolution:

      TIP: 
      To ensure security, change the default Administrator account User name and Password.
      NOTE: The Guest and Administrator Accounts are permanent and cannot be removed. Their settings can be modified.
      NOTE: If you give the Guest account any set of privileges other than "None", you are effectively giving unauthenticated users access to the features of the device. The security of the appliance's network should be considered before taking this step.

      Accessing User Settings
      Editing an Existing User
      Creating a New User
      Login Alerting Settings
       
      Accessing User Settings

      1) Log into the NetBotz appliance using the Advanced View application.
      NOTE: For instructions on downloading Advanced View, see knowledge base FA230223.

      2) Select the Configuration tab.

      3) Under Appliance Settings, double-click into Users.
       
      Editing an Existing User

      1) Select a user from the list and click Edit.
      NOTE: The default Guest and Administrator Accounts are permanent and cannot be removed. Their settings can be modified, with the exception of the Administrator account's privilege set.

      2) The following information can be edited:
      - Name: Descriptive name that displays in the Users list.
      - User Name: Username used for authentication.
      - Password (Verify Password): Password used in combination with the User Name for authentication.

      3) Click OK to save the changes.
       
      Creating a New User

      1) Select Add below the Users list.

      2) Provide the following information:
      Name:  Descriptive name that displays in the Users list.
      - User Name: Username used for authentication.
      - Password (Verify Password): Password used in combination with the User Name for authentication.

      3) Chose a Privilege Set (Listed below) from the drop down list and then click OK.
      Privilege Set Description
      Administrator Gives user access to all information and configuration icons.
      Application Gives user access to only the Navigation, Sensor Data, and selected portions of the Information/Action panes. User accounts configured with the Application privilege set can view the Cameras, Graphs, Alerts, and About panes.
      Application (with Alert Update) Gives user access to only the Navigation, Sensor Data, and selected portions of the Information/Action panes.
      The user can also resolve alert conditions for thresholds that are configured with the Return-To-Normal Requires User Input setting in their Advanced Settings. This privilege set does not permit access to the configuration pane.
      Sensor Gives user access to only the Navigation, Sensor Data, and selected portions of the Information/Action panes. User accounts configured with the Sensor privilege set can view the Cameras, Graphs, and About panes.
      This privilege set does not permit access to the Alerts pane, or to the Appliance Log, Change Root Password, and Reboot Appliance Tool menu selections.
      Sensor (No Camera) Gives user access to only the Navigation, Sensor Data, and selected portions of the Information/Action panes. User accounts configured with the Sensor (No Camera) privilege set can view Graphs and About panes.
      This privilege set does not permit access to the Cameras pane, Alerts pane, Configuration pane, or to the Appliance Log, Change Root Password, and Reboot Appliance Tool menu selections.
      None Does not permit access to any of the appliance features.
       
      Login Alerting Settings

      Login failure alert severity can be set to any of the following: None, Informational, Warning, Error, Critical, or Failure (default).

      Login failure alert profile to can set to any of the defined alert profiles to provide a login failure security email.

      How to calculate Energy readings from the raw Integer register data on an Energy Meter

      Issue
      The energy values are stored across two 16-bit integer registers on an energy meter. 

      Product Line
      Energy Meter

      Environment
      Reading and converting Modbus register values

      Resolution
      The Energy Meter stores energy across two 16-bit integer registers.

      Register #1 and Register #2 (Modbus address 257/258 for Register #1 and 259/260 for Register #2). Register #2 is the High WORD and Register #1 is the Low WORD. 

      The Multiplier/Divisor table states that both of these registers must be divided by 32 to obtain the real value from the raw data.
      The Multiplier/Divisor should NOT be applied to both registers. It is applied to the final value of both registers.

      To calculate the Energy the registers must first be arranged as the register list states [2] is the High word and [1] is the Low word.

      To make [2] the High word it needs to be shifted to the left 16 bits.
      To accomplish this multiply the value in [2] by 65,356.
      You will then add this value to the value in [1].
      The final value will be divided or multiplied by the correct scaling value. Please see the example listed below.

      For this example we will assume an Energy Meter with 300 amp CTs. According to the Integer Multiplier/ Divisor table, 300 amp CTs will give a divisor value, (d), of 32 and a multiplier value, (m), of 0.03125.
      We will assume the following register values.
      Register #1 = 29,586
      Register #2 = 31

      Using Divisor Table
      kWh = ([R2]*65,536+[R1])/d
      kWh = (31*65,536+29,586) / 32
      kWh = 64412.56

      Using Multiplier Table
      kWh = ([R2]*65,536+[R1]) * m
      kWh = (31*65,536+29,586) * 0.03125
      kWh = 64412.56

      *Note the divisor will not always be 32 and the multiplier will not always be 0.03125. For the correct values please see the Integer Multiplier Table.