Quantcast

General Accessories Screws, 16mm x M3.5 x 0.8 Pitch, Plated

General Accessories Screws, 16mm x M3.5 x 0.8 Pitch, Plated

General Accessories Screws, 16mm x M3.5 x 0.8 Pitch, Plated

Item Number: 353B

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Length

16 mm

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP060307EN

Others

Thread type

M3.5

Shape of screw head

raised countersunk

Package 1 Weight

1 g
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Specifications

  • Corporate Marketing

Frequently Asked Questions

hide show

Changing counter value while Hot Standby switchover

Goals and Symptoms

This resolution describes a workaround for an effect by a Hot Standby switchover with RIO and a software counter.
The RIO cable connection to the Primary CRP 931 fails.
An input from a 140 DDI 353 00 module has value "1" at the same time.
The Standby system switches to Primary (what is correct).
But the input bit gets for a short time the value "0", because the CRA is not available while switchover.

If the binary input is linked to a software counter the counter will change the value. Also affected are program parts, which use this binary input together with Edge detection.

Facts and Changes

Problem is known with the following components:
Concept 2.6 SR2
140CPU43412A, EXEC 1.25, Kernel 1.01
140CHS11000, EXEC 1.04, Kernel 1.00
140CRP93100, EXEC 1.15, Kernel 1.01
140 DDI 353 00

It should exist with all Hot Standby systems equiped with 140CRP93100, every discrete Input and a software counter or a Edge detection is linked to the Input module.

Causes and Fixes

Use the EN input of the software counter and link it to the healthy bit of the Input module. This avoids to increase the counter during RIO cable interrupt.


Legacy KB System (APS) Data: RESL167770 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Quantum

Where can one find technical information on the Powerpact H J and L circuit breakers?

Issue:
Technical information on Powerpact circuit breakers including ratings, accessories, terminations, trip units, trip curves, and dimensions

Product Line:
Circuit breakers

Environment:
Powerpact H, J, and L

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult  product catalog:
Powerpact H/J/L:  0611CT1001
See attachments for trip unit manuals.

For help with Micrologic trip units for Powerpact H, J, and L circuit breakers, including modbus communications, consult instruction manuals:
Powerpact H, J, L Micrologic types 0 1 2 3; see User Guide 48940-310-01
Powerpact H, J, L Micrologic types 5 6; see User Guide 48940-312-01
Powerpact H, J, L modbus communications, see ULP System User Guide 48940-329-01
Modbus™ Communication—User Guide For PowerPact™ H-, J- and L-Frame Circuit Breakers 48940-328-01
PowerPact™ H-, J-, and L-Frame Circuit Breakers Modbus Communication Guide 0611IB1302 

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.
 

Information on Powerpact M, P, and R breaker ratings, accessories, terminations, trip units, trip curves, dimensions, and troubleshooting

Issue:
Technical information on MCCB's and their ratings, accessories, terminations, trip units, trip curves, dimensions, application, and troubleshooting

Product Line:
Circuit Breakers

Environment:
Powerpact M P R circuit breakers

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult the product catalogs:
Powerpact M/P/R:  0612CT0101

For help with Micrologic trip units and modbus communications for Masterpact and Powerpact P and R circuit breakers, consult instruction manuals:
Powerpact P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03
Modbus™ Communications System for Micrologic™ A, P, and H Trip Units 0613IB1201
Powerpact P, R, and Masterpact NW, NT Micrologic™ Modbus User Guide 0613IB1313  (Contains information about the currently unavailable IFE Ethernet interface)

For selection information for catalog numbers for breakers and accessories, consult the Parts List:
Masterpact NT and NW:  0613DB1607

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.