Clipsal - General Accessories, Screws, 12mm X M3.5 X 0.8 Pitch, Plated

Clipsal - General Accessories, Screws, 12mm X M3.5 X 0.8 Pitch, Plated

Clipsal - General Accessories, Screws, 12mm X M3.5 X 0.8 Pitch, Plated

Item Number: 353

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Length

12 mm

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP060307EN

Others

Package 1 Bare Product Quantity

1

Thread type

M3.5

Shape of screw head

  • slotted
  • raised countersunk

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7 mm

Package 1 Width

7 mm

Package 1 Length

13 mm

Package 1 Weight

1 g

Unit Type of Package 2

BB1

Number of Units in Package 2

100

Package 2 Height

3.4 cm

Package 2 Width

5.2 cm

Package 2 Length

7.3 cm

Package 2 Weight

0.1 kg

Unit Type of Package 3

CAR

Number of Units in Package 3

10000

Package 3 Height

22.6 cm

Package 3 Width

19.1 cm

Package 3 Length

35.9 cm

Package 3 Weight

10 kg
Show all specifications

Frequently Asked Questions

hide show

Will NSX breaker trip if acknowledge Isd Alarm on Micrologic trip unit when the breaker is ON (Service)

Issue:
 
Will NSX breaker trip if acknowledge Isd Alarm on Micrologic trip unit when the breaker is ON (Service)
 
Product Line:
 
ComPacT NSX new generation

 
Environment:
 
NSX
 
Resolution:
 
Yes, reset the fault or acknowledge Alarm will not cause a C/B tripping.

However, customer should follow the Responding to a Trip and maintenance recommended for different trip condition mentioned in NSX User guide, page 191/216 on the NSX User guide as on this FAQ published date.
 

Can we add third party gateway as child gateway to PAS600 or PAS800

Issue:

Need to know if we can add third party gateway as child gateway to PAS600 or PAS800

Product Line:

Panel Server Universal

Environment:

PAS600 and PAS800

Resolution:

You cannot add third party child gateway to the PAS, as mentioned in user guide link below page 125/146 only native gateways listed can use as child gateway as of now 12/12/2022.

Please keep refer to the latest user guide for any new updates.

https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=DOCA0172EN-06.pdf&p_Doc_Ref=DOCA0172EN&_ga=2.228082717.1801643049.1670801858-1648353019.1661729931

Architecture Diagram
 

What are the remote reset (after fault trip) options in Masterpact MTZ ACBs?

When a fault trip happens, the fault trip indicator SDE indicates ‘fault’ and the blue fault trip reset button pops up. To close the breaker, the reset button needs to be pressed down.

To do a remote reset after fault trip, two solutions, RES and RAR, are provided.
image.pngimage.png



RES
Please see the following detailed explanation of RES from Masterpact MTZ Catalogue.
image.png
image.png

Example terminal block marking for RES for MTZ2/MTZ3 Fixed and drawout devices.
image.png

Please see below showing how blue reset button pops back in when the RES is used.
FAQ05_GIF.gif




RAR
Please see the following detailed explanation of RES from Masterpact MTZ Catalogue.
image.png

Please refer more details in Masterpact MTZ Catalogue and User Guide.
 

What is the part number for a 5 pole contactor with 3 N/O 2 N/C contacts and 240VAC coil?

The part number for a 5 pole contactor with 3 N/O 2 N/C contacts and 240VAC coil is - CAD32U7

For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/CAD32U7
User-added image
 

Where can I find information on the sw100, sw101, sw102 and sw103 dip switches on the ATV212 drives?

Issue:
ATV212 information from the SW101, SW102, and SW103 dip switches.

Product Line:
Altivar ATV212

Environment:
Altivar 212 drive

Cause:
Needs to know where they can find information on the dip switch settings.

Resolution:
There are 5 dip switches on the ATV212 drives
SW101= FM analog output U= voltage output I = current output
SW102= Sink Source switch
SW103= Term Switch. Selection of communication terminal resistor. When SW103 is set to Term, internal 120 Ohm termination resistor is connected between A and B terminals.
SW100= VIA= VIA analog input switch (U= voltage input or I= current input)
    VIB= VIB analog input switch (0-10-vdc input or PTC input)

  

    

 

What's the difference between a regular Home member, an Administrator and the Homeowner?

The Homeowner has access to all functions. Administrator has access to all functions except the ability to transfer the homeowner rights, delete the home and granting administrator rights to other members. A common member only has access to operate devices, receive notifications (alarm, moment/automation trigger, device added/removed and invite) from a home, configure device settings and schedules.

Show More