Quantcast

General Accessories Screws, 12mm X M3.5 X 0.8 Pitch, Plated

General Accessories Screws, 12mm X M3.5 X 0.8 Pitch, Plated

General Accessories Screws, 12mm X M3.5 X 0.8 Pitch, Plated

Item Number: 353

Retail
$23.33
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

Length

12 mm

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP060307EN

Others

Thread type

M3.5

Shape of screw head

  • slotted
  • raised countersunk
    • Package 1 Weight

      1 g

      Package 1 Height

      7 mm

      Package 1 width

      7 mm

      Package 1 Length

      13 mm
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Specifications

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      My lights won't dim correctly on a C-Bus Leading Edge Dimmer?

      Does this installation have 3 Phase power??

      If so, check that the 'Control' side and the 'Switching' Side of the Leading Edge Dimmer are connected on the same voltage phase! You are not able to have a separate voltage phase on either of these connections as this unit is not internally connected...

      See, Notes: on page 5 of the linked document

      image.png

      If this installation is a single phase configuration, check the Lighting Driver to make sure this is dimmable and is a Leading Edge driver.

      Some poor quality Lighting Drivers will result in a staggered or erratic dimming experience, we'd suggest trying other brands of drivers in this case, if the driver is built into the light fitting itself then we'd suggest trying a whole new fitting.

      Click HERE for the installation Instructions

      How do you wire an RCD RCD440/30 with no neutral?

      You need a 2200Ω resistor going from the outgoing neutralto the outgoing white phase. be sure there in no cable in the ingoing neutral terminal as that would create a dead short.

      This Task should only ever be performed by a licenced electrician.

      This image is not available because: You don’t have the privileges to see it, or it has been removed from the system

       

      What are the remote reset (after fault trip) options in Masterpact MTZ ACBs?

      When a fault trip happens, the fault trip indicator SDE indicates ‘fault’ and the blue fault trip reset button pops up. To close the breaker, the reset button needs to be pressed down.

      To do a remote reset after fault trip, two solutions, RES and RAR, are provided.
      image.pngimage.png



      RES
      Please see the following detailed explanation of RES from Masterpact MTZ Catalogue.
      image.png
      image.png

      Example terminal block marking for RES for MTZ2/MTZ3 Fixed and drawout devices.
      image.png

      Please see below showing how blue reset button pops back in when the RES is used.
      FAQ05_GIF.gif




      RAR
      Please see the following detailed explanation of RES from Masterpact MTZ Catalogue.
      image.png

      Please refer more details in Masterpact MTZ Catalogue and User Guide.
       

      What is the part number for a 5 pole contactor with 3 N/O 2 N/C contacts and 240VAC coil?

      The part number for a 5 pole contactor with 3 N/O 2 N/C contacts and 240VAC coil is - CAD32U7

      For further information, visit the link below:-
      https://www.schneider-electric.com.au/en/search/CAD32U7
      User-added image
       

      What is the current alternative to the LR1D40353A65?

      The current alternative is the LRD332 but that will not fit on the older versions of contactors, that will need to be mounting on an LC1D40A contactor.

      Where can I find information on the sw100, sw101, sw102 and sw103 dip switches on the ATV212 drives?

      Issue:
      ATV212 information from the SW101, SW102, and SW103 dip switches.

      Product Line:
      Altivar ATV212

      Environment:
      Altivar 212 drive

      Cause:
      Needs to know where they can find information on the dip switch settings.

      Resolution:
      There are 5 dip switches on the ATV212 drives
      SW101= FM analog output U= voltage output I = current output
      SW102= Sink Source switch
      SW103= Term Switch. Selection of communication terminal resistor. When SW103 is set to Term, internal 120 Ohm termination resistor is connected between A and B terminals.
      SW100= VIA= VIA analog input switch (U= voltage input or I= current input)
          VIB= VIB analog input switch (0-10-vdc input or PTC input)

        

          

       
      Show More