switch 1gang key operated

Switch, 1 Gang, 250VAC, 20A, 1 Way, Locks In On and Off Position, Key Operated

Catalogue Number: 31VK2
switch 1gang key operated
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Device presentation
basic element with full cover plate
Switch function
1-way
Actuator
key
Device mounting
flush
Fixing mode
by screws
Local signalling
without
[Ue] rated operational voltage
250 V AC
Rated current
  • 20 A
  • 16 AX, fluorescent lamp
    • Marking
      ON-OFF
      EU RoHS Directive
      Compliant
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      In the 31VK1 series can the key be removed in the " on " position ?

      No , to remove the key in the " on position a 31VK2 is required , 31VK1 will only allow key removal in the " Off " position.

      Do you offer a key switch like the 31VK2 but in the 2000 Series?

      No, Unfortunately we do not offer a key switch in the 2000 series. The only series we offer a key switch is the Standard Series and the industrial 56 Series.

      Can the key be pulled out in both ON and OFF position in 31VK2 and 31VK2/2 key operated switches?

      Yes, the key can be pulled out in both ON and OFF position in 31VK2  (one way) and 31VK2/2 (two way) key operated switches. They lock in ON and OFF position
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK2
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK2/2
      User-added image

      Are spare keys available for part number 31VK1?

      Keys can be provided as special order.

      Can i get multipule 31VK1 switches with the same key?

      Yes, you can get multiple 31VK1 switches with the same key.
      If you put CK after the part number they come with the same key.

      Some of the key features are:
      • Key Operated Switches
      • Common Keyed
      • Locks in off position

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK1CK

       

      In the 31VK switches what is the difference between a K1 and K2?

      The 31VK1 can have the key removed in the OFF position only while in the 31VK2 the key can be removed in both the ON and OFF positions.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=31VK

      Can the key switches from the 31VK series be removed and placed onto a 4 gang plate?

      No, unfortunately the key switch mechanisms are not removeable and therefore cannot be put onto any other plates.
      Some of the key features for the 31VK Series are:
      • 1 gang
      • Dimension: 115 mm Length x 73 mm Width x 11 mm Depth
      • Mounting centers: 84 mm
      • Common keyed switch
      • Locks in on and off position
      For further information please visit https://www.clipsal.com/Trade/search-results?q=31VK%20Series
       

       

      What is the code for an extended rotary handle for 31052 (INS400) ?

      Code = 31052 Suits INS320 to INS 630 - Black

      What is the dimension of 31VA, 32VA, 33VA, 34VA, 35V and 36VA standard sized vertical flush switches?

      31VA, 32VA,  33VA,  34VA,  35VA and 36VA standard sized vertical flush switches have a dimension of 115mm(length) x 73mm(width) x 11mm(depth). Mounting centres are 84mm apart. The switches are rated to 250V AC, 10A, 1 way/ 2 way.
      For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000108.pdf

       

      What is the substitution of an XBCD which isn't a catalogue version as the XBCD*9* ones ?

      Because these XBCD were variable composition ones, we can't give you an equivalence.

      The best is to indentify the scheme of the product and then to create a K1/K2 product.

      Is there a lockable double GPO in any residential range?

      No there isn't but you can install a 31VK1, upstream from the GPO and control the power to it that way...

      What is the part number for the key only for the 2036VKT4?

      The part number for the key only for the 2036VKT4 is 2036VKT.

      Some of the key features are:
      • To suit 2036VKT and 36VKT series switches
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2036VKT
       

      When polling dual registers in InfraStruXure Central 6.0, both registers must be polled together.

      Issue:

      When polling dual registers in InfraStruXure Central / StruxureWare Data Center Expert, both registers must be polled together.

      Product Line:

      InfraStruXure Central / StruxureWare Data Center Expert

      Environment:

      Modbus communications

      Cause:

      Modbus registers are limited in size, which limits the values they can store and return to a BMS. Unsigned values can not exceed 65535. Because some values returned by ISXC may be greater than this maximum value, we have created the ability to use 2 registers together as a pair to allow for this larger output. If you choose to configure 31001 as a dual register, it will encompass 31001 and 31002.

      Resolution:

      When polling these registers, poll both 31001 and 31002 (or whatever register pair you have set up this way) during the same poll. Failure to do so will return invalid results.

      ATV71 Load Sharing: : Needs a whitepaper on Load Sharing

      Issue:
       ATV71 Load Sharing: Needs a whitepaper on Load Sharing

      Product Line:
       ATV71

      Environment:
      Load sharing

       
      Cause:
       
      We don't have more than the training module concerning the load sharing, this document has been created from the development file where there are the same synoptic. However I attach the load sharing training module.

      . When LBA is equal to NO, the load balance function is not activated
      . When LBA is equal to YES, the load balance function is activated, and the correction using torque reference allows to reduce or increase the speed of the motor depending on the load.
      . The load balance speed correction could be adjusted by parameter :
      . LBF : adjust the time constant (low filter) of the torque reference
      . LBC : define the nominal speed load balance correction
      . LBC1 : define the low speed for torque decreasing function speed reference
      . LBC2 : define the high speed for torque decreasing function speed reference
      . LBC3 : define the torque offset for torque correction

      . The load balance speed correction is equal at : LoadBalanceSpeedCor = K1*K2 (see the diagram in training module)
      Reminder
      This function is used only in SVC vector control.
      Default value :
      LBC = 0Hz
      LBF = 100ms
      LBC1= 0Hz
      LBC2= 0Hz
      LBC3= 0%