timer 1gang 2wire 10a 254min

Time Delay Switch, 1 Gang, 250V, 10A, 254min, 2 Wire

Catalogue Number: 31VETR
timer 1gang 2wire 10a 254min
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 31VETR
Device presentation
basic element with full cover plate
Device mounting
flush
Material
plastic
Autonomy
4.233 h
[Ue] rated operational voltage
250 V
Network frequency
50 Hz
Rated current
10 A
Fixing mode
by screws
EU RoHS Directive
Compliant
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Specifications

  • Case Studies

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Do you have a two wire time delay switch available?

Yes, we do have a two wire time delay switch available. The part number is 31VETR.

I have 2 wire 31VETR and i dont have enough load will a 31CAP do the trick?

It will improve the situation however we cannot confirm wether it will fix the problem or not. The alternative is to use the three wire design 31VETR3

Is the 2031vetr available in the C2000 series?

It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

Do you have a weatherproof push button timer that does 2 hours?

No, not as a single part, but you can make one with a 56PB push button and a 31VETR timer.

Can the 31VETR , be used with 2 way switching ?

Yes , with the use of a bell press switch mech switching neutral to unit - 31VETR
emailed customer installation instructions...
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=31VETR
User-added image

What is the replacement for the OW3394 now obsolete ?

There is no direct replacement for the OW3394 however the 31VETF series can be used in most applications.
 
Electronic Timer Controls, Time Delay Switch 250V 10A - 10 minute run-on timer switch for fans / lights, rocker style mechanism.
Also comes in 2000 series 2031VETF.

Please see following link for more information and installation documentation.
https://www.clipsal.com/Trade/search-results?q=31vetf

Can part number 31VETR3 run a 1.6kw inductive load?

Yes, they will operate up to 2.4kw inductive load. 

What is the time delay available on the 31VETF or 2031VETF?

The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
rear of the device.

Can the 31VETR3 be used as normally open and normally closed contact?

Yes, the 31VETR3 can be used as normally open and normally closed contact.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf 

Image result for 31VETR3 Clipsal

Is the 2031VETR3 available in a 15 amp version?

No , The 31VETR series are available in 10a versions only
For more information regarding this product range please visit the Clipsal web site on the link provided.
https://www.clipsal.com/Trade/search-results?q=31vetr
User-added image

What type of switch mechanisms can be used to remotely switch 31VETR3 / 2031VETR3 push button timer?

Momentary switch mechanisms (Bell press mechanisms) can be used to remotely switch 31VETR3 / 2031VETR3. Example of 30 series momentary switch mechanisms are 30PBBP or 30PBBPL.
For further information, please visit 
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBP
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBPL

Can the 31VBER be time adjusted

The 31VBER can not be adjusted it operates only on the temperature

of the themostat in place.
for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VBER

User-added image

Does the 31VETR3 have the option of normally open or normally closed contacts?

Yes, the 31VETR3 has the option of choosing whether the contacts are normally open or normally closed.

Some of the key features are:
  • 3 wire - remote switch input
  • Neon indicator, programmable state
  • Delays between 10 secs and 15 hours
  • Push button to turn load on for set period
  • Toggle push-button to cancel timer
  • Programmable (NO or NC) output
  • No minimum load

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
 

Can the 31VETR3 be used with fans ?

Yes the product can be used with fan.
it is compatible with small motor loads max 2A

https://www.clipsal.com/trade/products/ProductDetail?CatNo=31VETR3

https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
 

Key Features

  • 3 wire - remote switch input
  • Neon indicator, programmable state
  • Delays between 10 secs and 15 hours
  • Push button to turn load on for set period
  • Toggle push-button to cancel timer
  • Programmable (NO or NC) output
  • No minimum load
  • Suitable for incandescent or fluorescent lighting
  • 10AX Maximum Load Current
  • OFF Power-Up Status 84mm Mounting Centres
  • AS/NZS3100, AS/NZS3133 AS/NZS CISPR15
  • 0 to 40 deg C Operating Temperature

 

How does the three wire push button timer 31VETR3 or 2031VETR3 work?

The built in push button on the 31VETR3 or 2031VETR3 has the following functions:
• Pressing the button when the timer is passive will initiate timing and set the load, and indicator, to the active state according to the configuration switch settings.
• Pressing the button during timing will cancel timing and set the load, and indicator, to the passive state according to the configuration switch settings.
• To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions.
For further information, please refer to the below link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3
 

Can the 2031VETR switch 24V DC?

No, it is only for 240V~.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Can the 2031VETR be two wayed?

Yes the 2031VETR can have a remote switch wired to it.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

Does the 2031VETR switch an exhaust fan?

Yes the 2031VETR will switch small motor loads. (maximum 2A)

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR


 

Does the 2031VETR have dip switches?

Yes, the 2031VETR does have dip switches.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR

How can 31VETR3/ 2031VETR3 push button timers be remotely switched?


For 31VETR3/ 2031VETR3 push button timers to be remotely switched, additional switches have to be installed in parallel, allowing the timer to be activated from one or more remote locations as shown in the wiring diagram below:


NOTE:
• The remote switch wiring must be rated for 240V a.c.
• The sum of cable lengths used to connect the remote switches must not exceed 100m.
• Remote switches MUST be Normally Open momentary operation type switches.
 

Is it possible to buy just the mech (mechanism) from a 31VBER-WE to place in a different series of plate styles ?

No - Unfortunately the mechanism is part of a complex relay system integrated with the electronics on this plate so it is impossible to remove the mechanism and place into a different plate.

Please see below link for more information.
https://www.clipsal.com/Trade/search-results?q=31vber

Can the 2031VETR and 2031VETR3 operate without a neutral?

The 2031VETR3 will not operate without a neutral however the 2031VETR WILL operate without a neutral as it was designed purely as a 2 wire device I.e. Active & Switched Active.

Is mech only available for part number 2031VETR?

No the mech comes only complete in plate.

What is the alternative for the sun set switch 31VSSR?

The alternative for the sunset switch 31VSSR is 56SSR/2.
Some of its key features are:
  • 2-Wire
  • Dimension: 101.5 x 101.5 x 69.7 mm
  • Timer Setting Range 2H, 4H, 6H, 8H, 12H, Default Setting: DD (Dusk to Dawn)
  • Light Intensity Setting Range 20-500 lux, Default Setting Approximately: 20 lux
  • Operating Temperature 0-45°C
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SSR/2
 

 

What is the part number for a booster element relay?

The part number for a booster element relay is 31VBER.

Some of the key features are:
  • 250V AC
  • 15A
  • For hot water element

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VBER

Can you use the 31VBER on a solar hot water system?

While Schneider Electric does not endorse the use of the product to modify or interfere with the normal operation of any solar hot water system.
It is best to discuss with the manufacturer of the solar hot water system on how to intergrate this in.

For more informaton please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VBER

What is the timing range for a 2031VETR-WE?

The timing range for a 2031VETR-WE is 15 seconds to 254 minutes.
Please see following link for complete range
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3

What is the minimum load for a 2031VETR?

The minimum load for a 2031VETR is 20mA.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001508.pdf 

is there a push button timer which i can place in a switch plate with other switches

We do not do a timer which is removable, the closest is a 2031VETR3-WE.
This comes on it's own plate which it cannot be removed from.
This timer allows the operator to push the button and will remain on until the time has lapsed.
please see below link for more information.
https://www.clipsal.com/Trade/search-results?q=2031vetr

Is there a timer switch in Saturn Series available?

No, however you can use the timer 2031VETR  as a remote timer ie place it in the ceiling and have cables running to a Saturn Series plate with a bell press. When the bell press is pressed it will trigger the 2031VETR.

Bell press part number is a 60PBBP

The saturn series plate less mechanism is 4061VH.

What is the part number for an OFF delay timer for a 20amp strip heater?

There is no OFF delay timer that has 20amp rating .
You can use run on timer  , 2031VETR , controlling 20amp contactor with 240VAC coil - LC1D09U7 for 20amp resistive load
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=2031VETR
https://www.schneider-electric.com.au/en/search/LC1D09U7
User-added image