timer 1g lt contrl delay fan

Time Delay Switch, 1 Gang, 250V, 10A, 10min

Catalogue Number: 31VETF
timer 1g lt contrl delay fan
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 31VET
Device presentation
basic element with full cover plate
Device mounting
flush
Material
plastic
Autonomy
0.166 hr
[Ue] rated operational voltage
250 V
Rated current
10 A
Fixing mode
by screws
EU RoHS Directive
Compliant
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Specifications

  • Case Studies

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the time delay available on the 31VETF or 2031VETF?

The 31VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the
rear of the device.

What is the replacement for the OW3394 now obsolete ?

There is no direct replacement for the OW3394 however the 31VETF series can be used in most applications.
 
Electronic Timer Controls, Time Delay Switch 250V 10A - 10 minute run-on timer switch for fans / lights, rocker style mechanism.
Also comes in 2000 series 2031VETF.

Please see following link for more information and installation documentation.
https://www.clipsal.com/Trade/search-results?q=31vetf

Do you have a two wire time delay switch available?

Yes, we do have a two wire time delay switch available. The part number is 31VETR.

I have 2 wire 31VETR and i dont have enough load will a 31CAP do the trick?

It will improve the situation however we cannot confirm wether it will fix the problem or not. The alternative is to use the three wire design 31VETR3

Do you have a weatherproof push button timer that does 2 hours?

No, not as a single part, but you can make one with a 56PB push button and a 31VETR timer.

Can the 31VETR , be used with 2 way switching ?

Yes , with the use of a bell press switch mech switching neutral to unit - 31VETR
emailed customer installation instructions...
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=31VETR
User-added image

Can the mech from 2031VETF be bought seperately ?

No, the mech is intergrated into the grid, and cannot be purchased seperately.

Is the 2031VETR3 available in a 15 amp version?

No , The 31VETR series are available in 10a versions only
For more information regarding this product range please visit the Clipsal web site on the link provided.
https://www.clipsal.com/Trade/search-results?q=31vetr
User-added image

Can part number 31VETR3 run a 1.6kw inductive load?

Yes, they will operate up to 2.4kw inductive load. 

Is the 2031vetr available in the C2000 series?

It is only available in either the standard series ( 31VETR) or 2000 series ( 2031VETR)

Can the 31VETR3 be used as normally open and normally closed contact?

Yes, the 31VETR3 can be used as normally open and normally closed contact.

For more information, please refer to the link:
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf 

Image result for 31VETR3 Clipsal

What type of switch mechanisms can be used to remotely switch 31VETR3 / 2031VETR3 push button timer?

Momentary switch mechanisms (Bell press mechanisms) can be used to remotely switch 31VETR3 / 2031VETR3. Example of 30 series momentary switch mechanisms are 30PBBP or 30PBBPL.
For further information, please visit 
https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBP
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PBBPL

Does the 31VETR3 have the option of normally open or normally closed contacts?

Yes, the 31VETR3 has the option of choosing whether the contacts are normally open or normally closed.

Some of the key features are:
  • 3 wire - remote switch input
  • Neon indicator, programmable state
  • Delays between 10 secs and 15 hours
  • Push button to turn load on for set period
  • Toggle push-button to cancel timer
  • Programmable (NO or NC) output
  • No minimum load

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
 

Can the 31VETR3 be used with fans ?

Yes the product can be used with fan.
it is compatible with small motor loads max 2A

https://www.clipsal.com/trade/products/ProductDetail?CatNo=31VETR3

https://updates.clipsal.com/ClipsalOnline/Files/Brochures/W0001273.pdf
 

Key Features

  • 3 wire - remote switch input
  • Neon indicator, programmable state
  • Delays between 10 secs and 15 hours
  • Push button to turn load on for set period
  • Toggle push-button to cancel timer
  • Programmable (NO or NC) output
  • No minimum load
  • Suitable for incandescent or fluorescent lighting
  • 10AX Maximum Load Current
  • OFF Power-Up Status 84mm Mounting Centres
  • AS/NZS3100, AS/NZS3133 AS/NZS CISPR15
  • 0 to 40 deg C Operating Temperature

 

How does the three wire push button timer 31VETR3 or 2031VETR3 work?

The built in push button on the 31VETR3 or 2031VETR3 has the following functions:
• Pressing the button when the timer is passive will initiate timing and set the load, and indicator, to the active state according to the configuration switch settings.
• Pressing the button during timing will cancel timing and set the load, and indicator, to the passive state according to the configuration switch settings.
• To restart the timer when the load is already on, simply perform consecutive turn-on and turn-off functions.
For further information, please refer to the below link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VETR3
https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETR3
 

How does 2031VETF run on timer switch operate?

The Clipsal 2031VETF Series is an electronic time delay switch which provides extended exhaust fan operations to ensure proper ventilation in bathrooms and toilets. It uses a single switch to operate both lighting and an exhaust fan. Both loads switch on simultaneously when the switch is operated, but when the lighting is turned off, the exhaust fan continues to run for several minutes.
Time Delay Intervals Available:
The 201VETF Series is adjustable to allow fans to continue to run from 3 minutes to 10 minutes (approximately) after the lighting is turned off. The delay adjustment is accessible on the rear of the device.
Operation:
Turning on the switch will cause both the lights and the fan to operate. The electronic timer starts when the switch is turned off. The lights are controlled directly by the switch, however, the fan will run for its preset timer period when the lights are turned off. Turning the lights on and off again, while the fan is still running, will cause the timer period to restart.
The fan will activate for a timer cycle whenever power is re-applied to the unit. eg. initial installation, power failure/return, fan replacement.
for further information. please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2031VETF
User-added image