outlet cooker 32a

Cooker Socket Outlet, 250VAC, 32A, 3 Pin

Catalogue Number: 31VCS
outlet cooker 32a
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Quantity per set
set of 1
Cover type
full cover plate
Marking
without marking
Local signalling
without light indicator
Device mounting
flush
Fixing mode
by screws
Material
plastic
[In] rated current
32 A
[Ue] rated operational voltage
250 V AC
Depth
11 mm
Length
115 mm
Width
73 mm
Fixing center
84 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Product Environmental

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      In the 31VK1 series can the key be removed in the " on " position ?

      No , to remove the key in the " on position a 31VK2 is required , 31VK1 will only allow key removal in the " Off " position.

      What is the white cover plate for a 2031VCS

      The part code is 2000-WE surround cover plate

      Are spare keys available for part number 31VK1?

      Keys can be provided as special order.

      What is the dimension of 31VA, 32VA, 33VA, 34VA, 35V and 36VA standard sized vertical flush switches?

      31VA, 32VA,  33VA,  34VA,  35VA and 36VA standard sized vertical flush switches have a dimension of 115mm(length) x 73mm(width) x 11mm(depth). Mounting centres are 84mm apart. The switches are rated to 250V AC, 10A, 1 way/ 2 way.
      For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000108.pdf

       

      Do you offer a key switch like the 31VK2 but in the 2000 Series?

      No, Unfortunately we do not offer a key switch in the 2000 series. The only series we offer a key switch is the Standard Series and the industrial 56 Series.

      Can i get multipule 31VK1 switches with the same key?

      Yes, you can get multiple 31VK1 switches with the same key.
      If you put CK after the part number they come with the same key.

      Some of the key features are:
      • Key Operated Switches
      • Common Keyed
      • Locks in off position

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK1CK

       

      Can the key be pulled out in both ON and OFF position in 31VK2 and 31VK2/2 key operated switches?

      Yes, the key can be pulled out in both ON and OFF position in 31VK2  (one way) and 31VK2/2 (two way) key operated switches. They lock in ON and OFF position
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK2
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VK2/2
      User-added image

      What is the part number for a replacement sunset switch for the 31VSST?

      The part number for a replacement sunset switch for the 31VSST is - 31VSSR/3

      For further information, visit the link below:-
      https://www.clipsal.com/Trade/search-results?q=31VSSR/3
      User-added image

       

      What is the alternative for the sun set switch 31VSSR?

      The alternative for the sunset switch 31VSSR is 56SSR/2.
      Some of its key features are:
      • 2-Wire
      • Dimension: 101.5 x 101.5 x 69.7 mm
      • Timer Setting Range 2H, 4H, 6H, 8H, 12H, Default Setting: DD (Dusk to Dawn)
      • Light Intensity Setting Range 20-500 lux, Default Setting Approximately: 20 lux
      • Operating Temperature 0-45°C
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56SSR/2
       

       

      NetBotz Version 1 Appliances Service Alert - January 2004

      Issue:

      NetBotz Version 1 Appliances Service Alert - January 2004

      Product Line:

      NetBotz

      Environment:

      NetBotz version 1

      Cause:

      NetBotz has discovered a software defect that affects our Series 300/400 appliances. This defect, which originates within the licensed operating system used by these appliances, can cause the appliance to become unresponsive on boot up. Series 300/400 owners should NOT reboot their appliances until the fix for this defect has been applied.

      Resolution:



      Appliance Models Affected
      This defect affects the following appliances:
      • WallBotz 300, 300B, 310, 310C, 400, 400C
      • RackBotz 303, 310, 310C, 400, 400C
      Note: WallBotz 500 appliances are not affected by this defect.

      Defect Description
      This defect is a result of intermittent, incorrect date/time computations carried out by the operating system during the appliance boot process. If a 300/400 Series encounters one of these time/date error it could result in a “system initialization” error during startup, causing the operating system to “hang” and the appliance to become unresponsive.

      Defect Resolution
      BotzWare v1.3.8 ensures appliance stability by working around this licensed operating system defect. Note that unlike most BotzWare updates this update is not available on the NetBotz updates web facility. Instead, this BotzWare update must be downloaded to, and installed to the appliance from, your workstation.

      To install the BotzWare v1.3.8 upgrade to you Series 300/400 appliance:
      1. Click here to download the BotzWare v.1.3.8 upgrade files.
      2. Once the download has completed, use a file compression/ decompression program (such as WinZip) to expand and save the upgrade image files to a temporary directory on your workstation.
      3. Start the Advanced View interface and then log into the 300/400 Series appliance you wish to upgrade.
      4. Start the Appliance Upgrade task.
      5. Click Browse Locally for Upgrade Images, use the file selection window to navigate to and select the BotzWare v1.3.8 upgrade image, and then click Upgrade to complete the upgrade procedure.
      6. Shut down the Advanced View interface. Then, restart the Advanced View and connect to the appliance you have just finished upgrading. You will receive a “Version Mismatch” error message, and will be prompted to upgrade the Advanced View interface. Click on Browse and use the file selection window to navigate to and select the netbotzclient.jar file that is located in the temporary upgrade images folder you created in Step 2.