switch 1g vert std ptn 10a 250

Flush Switch, 1 Gang, 250VAC, 10A, Standard, Vertical, PTN

Catalogue Number: 31VA
switch 1g vert std ptn 10a 250
Retail
$23.58*
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Black 1 PCE
  • Cream 1 PCE
  • Red 1 PCE
  • Resistant White Electric 1 PCE

Specifications

hide show
Range of product
Standard Series
Product brand
Clipsal
Device presentation
basic element with full cover plate and grid
Switch function
  • 1-way
  • 2-way
    • Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Fixing mode
      by screws
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      without marking
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the dimension of 31VA, 32VA, 33VA, 34VA, 35V and 36VA standard sized vertical flush switches?

      31VA, 32VA,  33VA,  34VA,  35VA and 36VA standard sized vertical flush switches have a dimension of 115mm(length) x 73mm(width) x 11mm(depth). Mounting centres are 84mm apart. The switches are rated to 250V AC, 10A, 1 way/ 2 way.
      For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000108.pdf

       

      What is the maximum cut out size of a Clipsal plate in the Standard Series?

      52mm x 76mm

      Example References (not comprehensive):
      31VX
      31VH
      31VA

      Is part number 32VA still available in Brown?

      Yes. Part number 32VA -BR is standard part.

      What is the inrush of a K range contactor

       The inrush is 30VA but the holding is 4.5VA

      what is consumption of lC1k0910B7 ?

      30VA In Rush 

      4.5 VA Sealed 

      In the 31VK switches what is the difference between a K1 and K2?

      The 31VK1 can have the key removed in the OFF position only while in the 31VK2 the key can be removed in both the ON and OFF positions.

      For further information please visit https://www.clipsal.com/Trade/search-results?q=31VK

      What is the part number of 1 gang flush switch plate less mechanism?

      31VH is 1 gang flush switch plate, Standard range less mechanism suitable for vertical/horizontal mounting.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31VH

      Can the key switches from the 31VK series be removed and placed onto a 4 gang plate?

      No, unfortunately the key switch mechanisms are not removeable and therefore cannot be put onto any other plates.
      Some of the key features for the 31VK Series are:
      • 1 gang
      • Dimension: 115 mm Length x 73 mm Width x 11 mm Depth
      • Mounting centers: 84 mm
      • Common keyed switch
      • Locks in on and off position
      For further information please visit https://www.clipsal.com/Trade/search-results?q=31VK%20Series
       

       

      Can you hardwire the input/output of the Matrix-UPS?

      Issue:
      Can the input or output of a Matrix UPS be hardwired?

      Product Line:
      Matrix UPS

      Environment:
      All serial ranges

      Cause:
      A user may wish to hardwire the input/output of the UPS rather than use the supplied input power cord.

      Resolution:
      APC offers a hardwire kit to be used with the 120/208 Matrix-UPS product. The part #s for these kits are as follows:

      MXA001: 5kVA Hardwire kit
      MXA002: 3kVA Hardwire kit

      These hardwire kits replace the standard back plate and allows the input and output of the Matrix to be wired directly to their corresponding electrical panels. This kit provides 120V, 208V and 240V on the output. The electrical specifications for both the Matrix 3kVA and Matrix 5kVA UPS systems are as follows:

      Input Over-current Protection
      3kVA: 20 A
      5kVA: 30 A

      Input/Output Wire Size
      3kVA: 12 AWG
      5kVA: 10 AWG


      Video: How do I replace the APCRBC140 or RBC44 battery modules in my SURT or SRT series Smart-UPS?

      Issue:
      How do I replace the batteries in my SURT or SRT series Smart-UPS?

      Product Line:
      Smart-UPS Online

      Environment:
      All SURT/SRT models 3Kva or larger, All Serial Numbers

      Cause:
      The average life span of a battery module is 3-5 years depending on environment and usage. For best performance the ambient temperature should be 68-77 degrees Fahrenheit. Replacing battery modules is a quick and easy process and can be performed without turning off the UPS. Please note that while you do not have to power down the UPS, you will not have any battery back up protection for the short period when no batteries are installed in the UPS.

      Resolution:
      All SURT and SRT units 3kva or larger use the APCRBC140 RBC Kit (This RBC kit replaced the older RBC44. APCRBC140 can be used in SRT or SURT unit, RBC44 only work in SURT)
      One APCRBC140 includes two battery modules
      3kva-6kva units use ONE APCRBC140 kit (Two Modules)
      8kva-10kva units use TWO APCRBC140 kits (Four Modules)

      To replace your batteries:
      • Remove the plastic bezel from the front of the UPS by pulling it off straight towards you
      • Remove the screws that hold the protective metal battery bay covers in place.
        • On 3-6kva units - Slide the cover to the left, then open like a door
        • On 8-10kva units - The bay covers come  off of the unit entirely
      • Disconnect the battery connectors by pulling straight out towards you
      • Slide the modules out of the UPS one by one. Be careful - They're heavy
      • Once all modules are removed, repeat these steps in reverse order to install new batteries
      • When the new batteries are installed, run a self test to clear any "Replace Battery" alarms

      Video: SRT UPS reports Battery Charger Event, Event Code 142

      Issue:
      The UPS reports: Battery Charger Event – event code 142 on the display or in the NMC event logs


       
      Product Line:
      SRT Models
       
      Cause:
      This event may be caused by a blown charger fuse, or bad batteries.
       
      Resolution:
      To determine the cause of this behavior, perform the following troubleshooting steps:
      • With the UPS input connected to AC mains, disconnect all the batteries in the system: all internal batteries and any external batteries, if used.
      • Go to the Status section on the display and under Battery, check Voltage.
      Note: You do not need to perform measurements on the UPS battery terminals.
      • If the voltage displayed on the UPS display is below the “Voltage level” (refer to the below values), the charger fuse is blown and the UPS requires replacement.
      • If the voltage displayed on the UPS display is at, or above, the “Voltage level, the batteries need to be replaced.
       
      Models Voltage level
      SRT 2.2kVA models If under 80V, the UPS should be replaced;
       
      SRT 3kVA models If under 100V, the UPS should be replaced;
       
      SRT 5-6kVA models If under 200V, the UPS should be replaced;
       
      SRT 8-10kVA models If under 200V, the UPS should be replaced;
       
      
       

      LED blocks: When, How, Which surge suppressors to implement.

      Goals and Symptoms

      LED blocks:
      When, How, Which surge suppressors to implement.

      Facts and Changes

      LED
      ZBV
      ZBZBV
      Suppressor

      Causes and Fixes

      - When to implement surge suppressors :

      If the LED is exposed to high voltage, short term spikes such as those created when large coils are de-energised ( solenoids, large contactor etc.) then damage may occur to the circuitry, causing a premature failure of the device. This damage can also occur where the inrush to the coil is high.

      The catalogue characteristics state that where the pilot light is fitted directly in parallel across an inductive coil, the inrush of the coil must not exceed 30VA. Remember that the inrush of the coil is usually very high compared to the nominal power consumption.
      If this value of 30VA is exceeded, then a suppressor block must be used in conjunction with the pilot light. It is also advisable to fit suppression across the inductive load to reduce the back emf produced.


      - How to implement surge suppressors :
      Connect the suppressor in parallel with the LED block.


      - Which surge suppressors to implement :
      ZBVJ* and ZBVB* => mostly used on 12Vdc or 24Vdc, the inductive loads are generaly low. However it is recommended to implement a freewheel diode. You can use the ZBZG156 which includes a diode.
      ZBVG* (110...120Vac) => Use ZBZVG (maximum power of coil 120VA).
      ZBVBG* (24...120V ac/dc) and ZBVM* (230Vac) => Use ZBZVM (maximum power of coil 230VA).


      For coils with a power above the suppressors limitation, use a dedicated suppressors on the coil itself:
      Freewheel diodes for DC applications.
      Bidirectionnal diodes or varistors for AC applications.


      Legacy KB System (APS) Data: RESL204809 V1.0, Originally authored by LaBe on 03/16/2011, Last Edited by LaBe on 03/16/2011