switch time delay hose proof

Pneumatic Timer Controls, Time Delay Switch 250V 10A - Weatherproof / Hoseproof

Catalogue Number: 319HP
switch time delay hose proof
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
EU RoHS Directive
Compliant
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Specifications

  • Case Studies

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What is the IP rating for the 319HP, pneumatic timer?

The IP rating for the 319HP, pneumatic timer is - IP65

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=319HP
User-added image

 

Is there a gland on the back of the 319HP

 Yes there is

What is the part number for a surface mount enclosure to suit 319HP Pneumatic timer?

238/25 is a surface mount enclosure with 25mm end entries that will suit 319HP.

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238/25

What is the maximum time for a Clipsal 319HP time delay switch

Primarily designed for up to 10 minutes with care 20 minutes may be possible.

FYI We now have a range of new timers and time clocks modules which can be installed into any iconic plate or a installed and triggered by any momentary switch they can be installed placed inside the flush box

What is the part number for weatherproof / hose proof pneumatic timer?

319HP is the part number for weatherproof / hose proof pneumatic timer rated to 250V, 50Hz, 10A-6AX.
IP rating of 319HP is IP56.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=319HP

 

Does part number 319RA come with 1 NC contact?

Yes the 319RA comes with 1 NC contact.

What is the code for the load correction device for OneTouch

 The part code 31CAP

Can you use a 31CAP on the 750WPR 3 wire sensor?

Yes, the 31CAP can be used on both 2 wire and 3 wires sensors.

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP

What is the NEMA 1 Kit for ATV71 over 350HP @ 575VAC?

Issue:
What is the NEMA 1 Kit for ATV71 over 350HP @ 575VAC?

Product Line:
AV71HC40Y
AV71HC50Y
AV71HC63Y

Environment:
Any.

Cause:
Nema 1 Kit part number.

Resolution:

There is no Nema 1 Kit for these 3 drives.
There is only the IP31 kit.
 

Can you use the 31CAP on a Leading Edge Dimmer?

No, the Leading Edge dimmer has a maximum input capacitance of 300nf, you would be able to use the 31LCDA as an alternative.
Trailing Edge and C-Bus Universal dimmers do not have a capacitance limit and either can be used.

I have 2 wire 31VETR and i dont have enough load will a 31CAP do the trick?

It will improve the situation however we cannot confirm wether it will fix the problem or not. The alternative is to use the three wire design 31VETR3

What are the characteristics of a 31CAP capacitor?

The characteristics of a 31CAP capacitor are:
Values Description
Amp 0.025A (Ampere)  =  25mA (Milliampere).
Watts 6W
Voltage 240V
Microfarad 0.33μF
Maximum amount stacked in parallel 3

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP

What is the minimum load required by the 2 wire infrascan?

The minimum load for a 2 wire infrascan is 40W. If the load is less than this you can use a 31CAP wired in paralel across the load.

Can a 751 be used with 25W LED?

Yes, it can but you will need to put a 31CAP in parallel with the load.

 

What is the dimension of INS43630, Optiline 50 manual pull up furniture box?

The dimension of INS43630 is 319mm /Ø112mm. Hole dimension: Ø100mm.
INS43630 Pop-up function desk unit, one-sided, manual. Configured with 1x double power outlet, Australian standard, with 3m 1.5mm2 external cable without plug and 2x 30 Mech/keystone data outlet. When inactive, the box lies flush with the desk-top. By a light pressure on the top, the box can be lifted up from the desk surface. As soon as the box is not in use, it is easily pressed back to the flush level. Earthed.
Material: Aluminium, natural anodized, and powder coated zinc and aluminum.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS43630
 

I have Saturn series LED switches in two way configuration that pulse when load is switched off

This can be corrected with the use of a 31CAP load correction Capacitor.

For further information on this product please visit the Clipsal website on the  link below
https://www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP
 

Why wont the 753SSR sensor turn off the lights, it is wired to a contactor?

Even though this is a 3 wire device it still has leakage current and enough to keep the contactor energised therefore your lights will remain on. The way to prevent this is to use a 31CAP in parralell with the load. This will provide an alternate path to neutral.

What is the difference between the 31Cap and 31LCDA?

The 31CAP is a load correction device which consists of a"Capacitor only " to help 2 wire products achieve minimum load levels. The 31LCDA has circuitry built in to the device  to enable it to correct minor compatibility issues found between dimmers and Led downlights for example slight flickering when dimmed at a higher level.



31CAP - Corrects the load for 2 wire devices.


For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP



31LCDA - Helps with compatibility issues.



For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=31LCDA

Will a 2-wire Infrascan 750WP Sensor operate with 20W load?

No, Unfortunately a 20W load will not operate a 2-wire Infrascan 750WP Sensor as it has a minimum load of 40W. You can increse the minimum load by adding multiple lights or a larger light. Alternatively you can install a product called a 31CAP which is a capacitor specifically designed to "increase" the minimum load. 

The characteristics of a 31CAP capacitor are:
Values Description
Amp 0.025A (Ampere)  =  25mA (Milliampere).
Watts 6W
Voltage 240V
Microfarad 0.33μF
Maximum amount stacked in parallel 3

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=31CAP

 

Where should the Load correction devices 31CAP and S31LCDA be used?

The 31CAP is to be use with the following two wire products
Infrascan 750WP, 751, 753.
Timer 31VETR
Sunset Switch WS226SSR/2, 56SSR/2, 31VSSR/2

The S31LCDA is suitable for use with Clipsal & Schneider Electric 2-Wire, mains powered Dimmers that use
Leading Edge, Trailing Edge and Universal Dimming.
Other Suitable loads: Dimmable CFL/ Dimmable LED with Electronic control

(Load correction Devices may not correct all problems)