SWITCH MECH 1-2W 10A SENSOR
switch mech 1/2w 10a sensor
SWITCH MECH 1-2W 10A SENSOR
switch mech 1/2w 10a sensor

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, SENSOR

Catalogue Number: 30MSEN
SWITCH MECH 1-2W 10A SENSOR
switch mech 1/2w 10a sensor
SWITCH MECH 1-2W 10A SENSOR
switch mech 1/2w 10a sensor
Retail
$26.72*
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Cream 1 PCE

Specifications

hide show
Range of product
  • Series 30
  • Standard Series
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
      2-way
      Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      sensor
      Marking location
      marking on surface
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • End of Life Manual

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Is the 30MBPN available in a 12V version?

      Yes, it is the part number is 30MBPN12.

      ION 6200 Digital Output - operational details not covered in the product documentation

      Product Line
      ION6200

      Environment
      Digital Outputs

      Resolution
      As energy accumulates, the ION 6200 digital output toggles from Open to Close, or from Close to Open, instead of pulsing. This is called KY pulsing. By default, the ION6200 meter has two Pulser modules preset to send pulses every 1 kWh and every 1 kVARh to the 2 solid state relays on the meter. The settings on the front for the defaults are out1 = wH, tc 1 = 1 and out2 =VArh, tc = 1. Notice that both out1 and out2 do not show k(kilo), but all out settings are in k(kilo), and that the tc(time constant) setting is also referenced as kT in some cases.
      Here are some parameter limits and operational constraints to keep in mind for the ION6200 meter:

      • Maximum Transition frequency = 20 per second
      • Minimum Period between Transition = 30ms, fixed
      • Kt Value must to set to a value greater than 0.1 for the digital output to operate correctly and accurately. This is due to bounds on the internal accuracy of the values maintained within the meter.

      Note also that the digital output toggles in batches at the beginning of each second. Thus, the digital output operates in bursts potentially at the beginning of each new 1 second boundary for no more than 600ms (20 transition x 30ms) in each one-second cycle. Calculations can be made to show that this implies that accuracy of measurements derived from this meter's pulsing capability must be averaged over at least a 15 minute period in order for them to reliably fall within the 0.5 accuracy class of this meter. This is not a reflection of the accuracy of the meter's measurement capability so much as a consequence of the specific way that this meter outputs measurement data via its digital outputs.

      At what point will Altistart ATS23 unit trip after light is flashing indicating it is pulling more than 130%?

      Issue:   At what point will Altistart ATS23 unit trip after light is flashing indicating it is pulling more than 130%?
       
      Product Line:   ATS23
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   Informed that this is a class 10 overload so looking at a table you see that at 150% it takes 90seconds, at 300% it takes 30sec & at 425% it takes 5 seconds so have to follow this.