30M MARKED MIRROR

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, MIRROR

Catalogue Number: 30M-MIRROR
30M MARKED MIRROR
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Series 30
  • Standard Series
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
    • 2-way
    • 1-way
      • Actuator
        rocker
        Number of rocker
        1
        Device mounting
        flush
        Local signalling
        without
        [Ue] rated operational voltage
        250 V AC
        Rated current
        10 A
        Marking
        mirror
        Marking location
        marking on surface
        Sustainable offer status
        Green Premium product
        REACh Regulation
        Reference contains Substances of Very High Concern above the threshold
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN
        Circularity Profile
        N/A

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Technical Leaflet

        • Installation Instruction

        • Specifications

        • Certificates (MSDS)

        • Corporate Marketing

        Frequently Asked Questions

        hide show

        ETSNZ - How can we use the M221 to read UINT32 and FLOAT32 data types out of a Power meter PM5300?

        Symptoms:
        • If you use the READ_VAR at address 130 with quantity = 1 you will get an error : CommError = 254 and OperError = 3.
        • If you change the quantity = 2 you will still get the same error : CommError = 254 and OperError = 3: You will get the high order byte in %MW130 = 0 and lower order byte in %MW131 = 0.
        The general register list for the Power meters gives you the Jbus addressing registers and not the Modbus addressing registers.
        Jbus addressing starts a n and the Modbus addressing then should be n -1.
        • If you now use the READ_VAR at address 129 (n -1) with quantity = 1 you will get the same error : CommError = 254 and OperError = 3.
        • If you change the quantity = 2 life is good: You will get the high order byte in %MW130 = xxxx and lower order byte in %MW131 = xxx.

        SoMachine Basic FB send receive SMS: Com Error 255 with Oper Error 16

        OperError Codes when CommError Code is 255 (Message refused) 
         
           Values   Operation
         
        16
          Phone number of the received message not matching with the list (white list protection)
        17
        Received message doesn’t match with the cmd list (issued only if the sender phone number matches with the one entry of the phone list)

        Solution:
        16 : Write the Phone number list with international notation, exemple: for 0518497647 use 33518497647  where 33 is the international code number of the country.
        17 : The received message must be the same as the one configured (Case sensitive)