switch mech 1/2w 10a alarm

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, ALARM

Catalogue Number: 30AM
switch mech 1/2w 10a alarm
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Standard Series
  • Series 30
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
      2-way
      Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Surface finish
      glossy
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      alarm
      Marking location
      marking on surface
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the cable for the Lexcom system

      Use VDIR534830 for the 300m drum

      How many Boxes of 305m 2D4P6IPV3B-BU in a pallett ?

      There are 36 boxes (Rolls) of 305M Cable per pallet.

      What is the replacement code for a 29587 breaker

       Use a LV438575 - NSX100N 30Amp 1P 50kA breaker

      Is part number 30MAM available in 15amp?

      The part number is a - 30MAM15

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MAM15


      User-added image

      Is the 3105RG6Q3B RG6 quad shield coax 305m cable FOXTEL approved?

      The 3105RG6Q3B RG6 quad shield coax 305m cable is FOXTEL and Austar approved.

      The Foxtel approval number is F10129 and the Austar approval number is P07982.

      What Earth leakage protection relay do i need?

      Firstly Choose from the two types of relays, (DIN rail mount or Front-panel mount) Using the tables below.
      Then make a selection dependent on the voltage required along with the settings desired.


      Vigirex Earth Leakage Protection Relay (DIN rail mount)
      TYPE POWER SUPPLY SETTINGS REFERENCE
      RH21M 12 to 24V AC- 12 to 48V DC 30mA-Inst, 300mA-Insta or 300mA-60ms 56160
        48V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56161
        110 to 130V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56162
        220 to 240V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56163
        380 to 415V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56164
        440 to 525VAC 30mA-Inst, 300mA-Insta or 300mA-60ms 56165
      RH99M 12 to 24V AC- 12 to 48V DC 30mA to 30A- Inst to 4.5s 56170
        48V AC 30mA to 30A- Inst to 4.5s 56171
        110 to 130V AC 30mA to 30A- Inst to 4.5s 56172
        220 to 240V AC 30mA to 30A- Inst to 4.5s 56173
        380 to 415V AC 30mA to 30A- Inst to 4.5s 56174
        440 to 525V ac 30mA to 30A- Inst to 4.5s 56175




      Vigirex Earth Leakage Protection Relay (Front-Panel mount)
      TYPE POWER SUPPLY SETTINGS REFERENCE
      RH21P 12 to 24V AC- 12 to 48V DC 30mA-Inst, 300mA-Insta or 300mA-60ms 56260
        48V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56261
        110 to 130V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56262
        220 to 240V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56263
        380 to 415V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56264
        440 to 525VAC 30mA-Inst, 300mA-Insta or 300mA-60ms 56265
      RH99P 12 to 24V AC- 12 to 48V DC 30mA to 30A- Inst to 4.5s 56270
        48V AC 30mA to 30A- Inst to 4.5s 56271
        110 to 130V AC 30mA to 30A- Inst to 4.5s 56272
        220 to 240V AC 30mA to 30A- Inst to 4.5s 56273
        380 to 415V AC 30mA to 30A- Inst to 4.5s 56274
        440 to 525V ac 30mA to 30A- Inst to 4.5s 56275
      RHU 220 to 240V AC 15mA to 30A- Inst to 5s 28560(1)

      Then choose a Toroidal to suit:
      Vigirex Sensors (Toroidal and rectangular)
      TYPE DESCRIPTION DIMENSION RATED OPERATIONAL CURRENT REFERENCE
      Closed Toroid,A-type TA30 30mm 65A 50437(2)
        PA40 50mm 85A 50438(2)
        IA80 80mm 160A 50439
        MA120 120mm 250A 50440
        SA200 200mm 400A 50441
        GA300 300mm 630A 50442
      Split Toroid, OA-type POA 46mm 85A 50485
        GOA 110mm 250A 50486
      Rectangular Sensors Small Rectangular Sensors 280 x 115mm 1600A 56053(3)
        Large Rectangular Sensors 470 x 160mm 3200A 56054(3)

      For further information please visit https://www.schneider-electric.com.au/en/


      Vigirex RH10MP-RH21MP-RH99MP-RH197-RHU


       

      What is the part code for a Cat5 cable in pink?

      The part code is 5005C305B, sold in 305m boxes.

      What length does the 2D4P6AIPV3R-BU cable come in?

      2D4P6AIPV3R-BU comes in a 305M box

      Is the PDL 30A switched

       No it is not

      What is the code for our external Cat6 Cable?

      The part code is ACT4P6UPEJ3RBK and it comes in a 305m Box.

      Is there a part similar to the grid plate 2031VX that has a terminal block on the back?

      Yes, The grid plate has a terminal block on the back and is rated at 30A. The part number is 2031VXCB.

      Can you wire an over ride into a 2 wire 750WP?

      Yes. In order to get the system to work, you will need to wire in either 2x 30M's or a 30MAM into a wall plate and connect to the sensor.

      For further information on the sensor, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=750WP

      User-added image

      Is 30m series mech available in colour 3A?

      Yes, the part number is 30M is a -3A.


       

      What is the UL wire specification for the NSYTRP44 terminal block?

      Issue:
      What is the UL wire specification for the NSYTRP44 terminal block?
      Product Line:
      Linergy TR Screw terminal blocks.
      Environment:
      Linergy TR NSYTRP44, NSYTRP44BL,
      Cause:
      To clarify the wire selection for the customer’s application.
      Resolution:
      600V, 30A, 24-10AWG, which is found on page 61 in the LINERGY CATALOG 9080CT1301
       

      What do I need to put together a single phase 30A 56 Series RCD

      Use 56CB4 + A9R51240 40amp RCCB

      What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

      Product Line:
      Circuit Breakers

      Environment:
      Electrical Distribution Equipment

      Resolution:
      The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

      whta is the Adaptor plate for ZB4 to go in a 30mm hole?

      The part number for the adaptor plate for mounting a ZB4 unit into a 30mm hole is ZB4BZ012.
       

      what is the part number for CAT7 cable.

      The part number is 2D4P7ALSF3R-OR.
      This comes in a 305m box and is orange in colour unlike Cat 6 and below which is normally blue.
      Please see Internet link for more products and detail relating to this product.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2D4P7ALSF3R

      What is the maximum DALI line length?

      The maximum length of a DALI line is 300m (when using minimum 1.5mm cable). If there is a specific requirement to use a line length of over 300m, it is possible to use a device such as a DALI repeater. As this is not a DALI CONTROL product, a 3rd party device would need to be sourced

      Is there a 30M sensor?

      No, however we have a sensor mechanism to suit the PDL range. the part number is 100MPIR.

      Is 30M available marked SPA?

      Yes, part number is available as standard 30MSPA

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MSPA

      30mm 480V LED Light Modules

      Issue:
      Are there 30mm light modules for 480V with LED lights?

      Product Line:
      30mm Operators - GIC Product

      Environment:
      US Product

      Cause:
      Product Selection

      Resolution:
      There are several light modules available:
      9001KM5LG - green
      9001KM5LR - red
      9001KM5LY - yellow

      Do we offer a Keyed 30mm Emergency Stop Mushroom Head Push button

      Issue:
      Do we offer a Keyed 30mm Emergency Stop Mushroom Head Push button

      Product Line:
      9001

      Environment:
      Pushbuttons 

      Resolution:
      No. We don`t offer a key release mushroom button in any of the 30 mm lines. Only on the 22mm.

      What is the part number for a Green indicator for 30mm diameter hole 24VDC ?

      The part number for a Green indicator for 30mm diameter hole 24VDC is - 9001KM35LG & 9001G6

      For further information , visit links below:-
      https://www.schneider-electric.com.au/en/search/9001km35
      https://www.schneider-electric.com.au/en/search/9016

      What is the part number for a 30mm Cylindrical 2 wire proximity sensor with 15mm sensing distance, prewired 2 metre cable?

      The part number for a 30mm Cylindrical 2 wire proximity sensor with 15mm sensing distance, prewired 2 metre cable is - XS630B1MAL2
      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/XS630B1MAL2
       

      What is the part code for a CBUS 30M wall switch (master)

       The part code is 5031NMML

      Is there a 30mm pusbutton turn to release Emergency Stop with trigger-action feature?

      Issue:
      Does Square D offer a 30mm pusbutton turn to release Emergency Stop  with trigger-action?

      Product Line:
      30mm Push Buttons                       

      Environment:
      9001 Type K and SK Heavy Duty Operators

      Cause:
      Clarify that Schneider Electric offers a trigger-action Emergency Stop.       

      Resolution:                                                                 
      The newly introduced 9001KR16 and 9001SKR16 Harmony 30mm Turn-to-Release includes the trigger-action feature.

      Do we offer a a flashing 24V pilot light in the 9001 30mm line? What is the part number for a Flashing amber 24 vdc pilot light 30mm?

      Issue:
      Do we offer a flashing 24V pilot light in the 9001 30mm line?  What is the part number for a Flashing amber 24 vdc pilot light 30mm?
      Product Line:
      30mm Push Buttons                       
      Environment:
      9001K/SK light modules
      Cause:
      Looking for a flashing pilot light.              
      Resolution:
      This is not offered in the 30mm lines.

      What is the dimension of a Heritage shallow to porcelain base versions

      Shallow approx 25mm + toggle
      Porcelain base 30mm + toggle

      What is the part code for a Harmony Stop Plug in 30mm

      No longer available use 30-20mm adaptor and 20mm plug

      What is the 30mm to 22mm adaption plate for pushbuttons?

      The adaptor is ZB2BZ4

      L1 VME What size Fixing Screws for the PDL 600 Series are available?

      16mm, 30mm and 50mm Long 

      What is the part number for 30M for 3 way installation?

      The part number for 30M for 3 way installation is 30MI.
      Please click this link for further information
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MI

      Is there a contact block in 30mm Push to Test Pilot Lights

      Issue:
      Is there a contact block in 30mm Push to Test Pilot Lights

      Product Line:
      9001

      Environment:
      Pushbuttons / Pilot Lights

      Resolution:
      Yes. 9001KA1 prewired.

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Goals and Symptoms

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Facts and Changes

      Advantys Configuration software.

      Causes and Fixes

      The pinouts for both cables are identical. The only difference is the type of connector that is used on
      the end of the cable and the length of the cable. The 'LU9RCD03' uses a straight connector and an
      angled connector and is 30cm long. The STBXCA1003 uses two angled connectors and is 4.5m long.
       


      Legacy KB System (APS) Data: RESL198335 V1.0, Originally authored by AlCh on 05/04/2009, Last Edited by AlCh on 05/04/2009
      Related ranges: Advantys STB

      If 755RPL is wall mounted, what is the minimum distance it can be from the ceiling?

      When wall mount the 755RLPSMA2, the minimum distance it can be mounted from the ceiling is 30cm with a maximum of 50cm.
      Some of the key features are:

      • New look design with easy to use test/hush button
      • Sealed-in rechargeable lithium backup battery
      • Quality optical chamber with stainless steel insect screen
      • Easy installation and maintenance
      • Wired interconnect feature (up to 40 alarms)
      • Optional relay or wireless interconnect bases
      • Backwards compatible with 755PSMA and 755SMA mounting bases
      • Robust digital design


      For further information please visit www.clipsal.com/Trade/search-results?q=755RLP

       

      Explanation of circuit breakers in 30 amp rPDU's

      Product Line
      • Rack Power Distribution
        • AP7XXX, AP7XXXB, AP8XXX series

      Environment
      • All serial numbers

      Resolution
      Circuit breakers are in place to protect the branch circuit and its conductors. With respect to a 30A breaker, all components employed in the circuit (downstream from the circuit breaker) shall be rated for 30A use. In a scenario where a 30A circuit breaker is providing power to a 20A rated outlet, the outlet, load plug, load cord and load are rated for 20A use, thus sized for this rating. In this scenario there is inadequate protection for the outlet and all connected equipment, and potentially (and most harmfully) the conductor that is supplying the outlets themselves.

      In North America, Canada, and Europe, PDU's are evaluated under UL/CSA/EN/IEC 60950-1. This standard requires circuit breaker protection when the rating of an output is less than the rating of the input. A PDU with a 30A input plug and 20A receptacles must have circuit breakers. Section 2.7 of the 60950 standard states: "Protective devices necessary to comply with the requirements of 5.3* must be included as part of the equipment" 

      *5.3 is the evaluation of abnormal operating and fault conditions.


      In North America, the requirement is based on NFPA 70, the National Electrical Code. In general, in the United States, you can have any outlet rated less than 20A protected by a 20A breaker. However, these outlets must have protection rated no less than the outlet rating and no more than 20A. A 30A outlet must be protected by a 30A breaker and may not have anything larger or smaller.

      Europe has very similar rules to North America. The main difference is the rating of receptacles and breakers. In Europe, you typically have 10A or 16A outlets protected by a 16A breaker, but the breaker rating can be no more than 16A.

      Canada places additional restrictions. In Canada, a 15A outlet must be protected by a 15A breaker. The only exception is the "T-Slot" 20A outlet that accepts either 15A or 20A plugs. This outlet may be protected at 20A.


      If a PDU has a 30A plug and 30A receptacles, it will not require and internal circuit breaker. The 30A plug forces it to be plugged into a 30A branch circuit, which will have its own 30A breaker. The PDU can then rely on the branch circuit's breaker rather than an internal breaker.

      If a PDU has a 30A plug and 20A receptacles, it must have internal 20A branch rated breakers for the receptacles. The 30A protection of the branch circuit is too high to be safe for the 20A outlets.

      How many Amps are the standard 30 mechanisms rated to?

      A standard 30M mechanism is rated at 10 Amps.
      Some key features are:
      • Terminal bores of 4.1 mm diameter accommodate 4 x 1.5 sq mm or 3 x 2.5 sq mm cable
      • Body fits 22 mm diameter hole
      • Motor rating is 100
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30M

       

      What part should I use to mount a 22mm push button into a 30mm size hole?

      Issue:
      Is there any mounting kit or adapter that we can use for a 22mm to a 30mm hole?

      Product Line:
      22mm Push Buttons / Operator Interfaces

      Environment:
      All Product Lines

      Cause:
      Can not find it in the Digest

      Resolution:
      Use mounting kit part number ZB4BZ021.

      What is the part number for a 56 series 1 gang cover with a 30mm hole in the centre?

      The part number for a 56 series 1 gang cover with 30mm hole in the centre is - 56L1/30

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56L1/30

      User-added image

      What is the part number for a 2 position 30mm diameter 9001K key selector switch head lockable in OFF position?

      The part number for a 2 position 30mm diameter 9001K key selector switch head lockable in OFF position is - 9001KS11K1

      For further information, visit the link below:-
      https://www.schneider-electric.com.au/en/search/9001KS11K1
      User-added image

      What is the part number for a punch for the 30mm hole for the 9001 K, SK, and KX operators?

      Issue:
      Does Square D offer or have a tool for punching/drawing a hole for 30mm push buttons?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Need to make a knock out on the undrilled enclosures for 30mm operators.

      Answer:
      Square D doesn not offer that tool.  We can recommend Greenlee knoct out punch #60242.

      What is the Maximum run of Cat 7a Cable 2D4P7ALSF3R ?

      All category data cables are defined by their maximum bandwidth at 100m. So 100m is the maximum recommended cable run.

      Cat 7A only comes in orange sheath to distinguish from other Data cabling and is supplied in a 305M box.

      Please see following link for technical specifications.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=2D4P7ALSF3R

      Is there RG6 cable available that is suitable for underground burial?

      Yes, we sell RG6 Cable that is able to be buried. The 3105RG6Q3RF is flooded cable with an anti-corrosive sealant impregnated into the body of the shielding.

      Some of the key features of this product:
      • Coaxial cable to suit satellite TV
      • Cable type: RG6
      • Quad shield
      • Flood burial
      • Pack size: 305m reel
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=3105RG6Q3RF

      User-added image

      What is the part number for the standard 30M rocker mech with the red indicator mark on the top ?

      30MRD-WE (White)

      Within the catalogs in the characteristics section for the RPF relays, it mentions that for the Rated operational current in utilisation categories AC...

      Goals and Symptoms

      Within the catalogs in the characteristics section for the RPF relays, it mentions that for the Rated operational current in utilisation categories AC-1 and DC-1: Conforming to IEC N/O=30A N/C=3A Conforming to UL 30A. Why is so big the difference between N/O and N/C ratings in IEC?

      Causes and Fixes

      The NO contact is dedicated to switch power loads.
      The NC contact is dedicated for low power control (PLC, pilot light...)


      Legacy KB System (APS) Data: RESL200159 V1.0, Originally authored by LaBe on 10/02/2009, Last Edited by LaBe on 10/02/2009
      Related ranges: Zelio Relay

      Are the 9001K51 and 9001K52 closing plate metal or plastic?

      Issue:
      Requested to clarify if the 9001K51 and 9001K52 is metal or plastic before purchase.
      Product Line:
      30mm Closing Plate
      Environment:
      30mm K and SK control stations, 9001K51 and 9001K52 30mm 30 mm 9001 9001k plug hole enclosure ky sky kyp skyp control station box accessories accessory   Push Buttons
      Cause:
      Request from vendor before purchase is placed
      Resolution:
      The closing plate both 9001K51 and 9001K52 is plastic with a metal ring nut that secures the plate to the enclosure.  Meets UL and Nema 1, 2, 3, 4, 4x, 6, 12, and 13.
       

      What are the dimensions of the 4FCC15SK ?

      Dimensions are Height 347mm , width 514mm and depth of 30mm

      What is the mounting hole diameter of a 30mm pushbutton?

      Issue:
      What size is the mounting hole for a 9001KX  30mm pushbutton?

      Product Line:
      Pushbuttons and Operator Interface

      Environment:
      9001K, 9001SK and 900KX 

      Cause:
      Product Features

      Resolution:
      31 mm or 1.22 inches.

      Is a 9001KY3 available with an extra conduit entry in the top?

      Issue:
      Is a 9001KY3 available with an extra conduit entry in the top?
      Product Line:
      30mm Enclosures
      Environment:
      9001KY/SKY Control Stations
      Cause:
      Need clarification before control station is installed.                        
      Resolution:                                                                 
      No, the 9001KY enclosures have a bottom conduit opening standard. Extra conduit openings are not available.
       