switch mech 1/2w 10a air con

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, Air COn

Catalogue Number: 30ACM
switch mech 1/2w 10a air con
Colour: White Electric
Colour: Per UOM Std.
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Standard Series
  • Series 30
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
      2-way
      Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Surface finish
      glossy
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      air conditioner
      Marking location
      marking on surface
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Saturn - is there an option for banana mechanisms in this range?

      YES - 30BCRM OR 30BCBM OR both in a 4031 or 4032 Communication plate.

      What is the part number for a speaker cable mechanism?

      The part number for a speaker cable mechanism is a 30BCBM for black and a 30BCRM for red.
       

      What is the min bend radius for the Actassi Fibre Connectors

      The min bend radius is 3.8cm

      Does the Clipsal range have a PDL 30AWH version in black

       No, only available in white

      What is the part code for a back plate from the Gael range dimensions 610 x 305mm

       The part code is BP24/12

      What is the replacement code for a 29587 breaker

       Use a LV438575 - NSX100N 30Amp 1P 50kA breaker

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Goals and Symptoms

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Facts and Changes

      Advantys Configuration software.

      Causes and Fixes

      The pinouts for both cables are identical. The only difference is the type of connector that is used on
      the end of the cable and the length of the cable. The 'LU9RCD03' uses a straight connector and an
      angled connector and is 30cm long. The STBXCA1003 uses two angled connectors and is 4.5m long.
       


      Legacy KB System (APS) Data: RESL198335 V1.0, Originally authored by AlCh on 05/04/2009, Last Edited by AlCh on 05/04/2009
      Related ranges: Advantys STB

      If 755RPL is wall mounted, what is the minimum distance it can be from the ceiling?

      When wall mount the 755RLPSMA2, the minimum distance it can be mounted from the ceiling is 30cm with a maximum of 50cm.
      Some of the key features are:

      • New look design with easy to use test/hush button
      • Sealed-in rechargeable lithium backup battery
      • Quality optical chamber with stainless steel insect screen
      • Easy installation and maintenance
      • Wired interconnect feature (up to 40 alarms)
      • Optional relay or wireless interconnect bases
      • Backwards compatible with 755PSMA and 755SMA mounting bases
      • Robust digital design


      For further information please visit www.clipsal.com/Trade/search-results?q=755RLP

       

      Will the 30RSM mechanism fit into a Saturn plate?

      No, unfortunately this mechanism does'nt fit the Saturn series. However, this mechanism will fit into the coms Saturn series comunication plate 4031VH.

      What is the part code for a sky connection 30 series mech

       Part code 30PFM

      What is the part code for a Clipsal Telephone Mech

       The part code is 30BTM

      Is part number 30MAM available in 15amp?

      The part number is a - 30MAM15

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MAM15


      User-added image

      What is the F type connector plates with dual outlets

      Not available as complete.  Use 2 x 30PFM and a 2 gang plate

      What is the part code for TV mechs 30 series - F type front and back

      Use a 30PFM mech

      What parts are required to make a Saturn permanent connection unit (PCU)?

      4032VH + 30USM + 38TB

      Is part number 30USM Double pole?

      No, part number 30USM is not a double pole.

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM


      User-added image

      Are the keys available for part number 30TKM?

      The keys for part number 30TKM are only available as a special.
      We don’t do them as a standard part.

      Is the 30BTM Clipsal Telephone Mechanism available in Black ?

      No, Not Available in Black 

      What does the Clipsal BT 2 Wire Telephone Mechanism (30BTM) look like?

      please follow the limk

      What is the part number for our 300mm ex-fan?

      The part number for Clipsal 300mm ex-fan is - 6230-0

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=6230-0
      User-added image

      What is the part number for a 300mm ceiling exhaust fan?

      The part number for a 300mm ceiling exhaust fan is - 6230-0

      For further information, visit the link below:-
      https://www.clipsal.com/Trade/search-results?q=6230-0
      User-added image

      Is there a 15A Surge protected outlet?


      To obtain a surge protected 15A outlet you will need to purchase a C2015/15X and a 30SFM and replace the extra switch in the outlet with the 30SFM surge protector mechanism and then wire accordingly.
      For some reason we have given the 30CSFM a 10A rating. The mechanism only needs to be rated for the correct voltage and correct fault current the amperage rating is irrelevant as this device does not have the load passing through it, it is there merely for fault conditions.

      Is the PDL 682 available in a keylock version

      Not available, you can use the Clipsal 30TKM this can be fitted in a single VH plate (C2031VH)

      Can the 30TKM be installed in any Clipsal range of switch plates?

      Yes, it can be installed in any switch plate that will take a 30 series mechanism.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30TKM 


      Can the 30TKM be installed in any Clipsal range of switch plates?

      Yes, it can be installed in any switch plate that will take a 30 series mechanism.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30TKM 

      What is the part number for a mounting block that can be mounted on a circular 300mm pole?

      The part number for a mounting block that can be mounted on a circular 300mm pole is - 2000MF300
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=2000MF300

      User-added image

      What is the phone and permanent connection mechs for the Clipsal Slimline plates

      Slimline fits all 30 Series mechs.  Permanent connection unit is the 38TB, phone mech is 30BTM

      Which mechs fit the Clipsal BSL Range ?

      Any 30 series Clipsal mech will fit.  30BTM is the telephone mech, available in white only.  30FFPFMS is the TV mech.

      What data and telephone jacks do we have to suit Saturn series

      You can use 4030VH plates and the 30 series mechs i.e. VDIB17735U, VDIB17756U, VDIB17736U & 30BTM

      Is there a "Draftstoppa" to suit the 6500A?

      No. Our Draftstoppa only suits round exhaust fans up to 300mm diameter.

      What is the part number for strip cable 300MM X 15MTR?

      The part number will be 287R300HD15-EO.
      For more information please follow the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=287R300HD15

       

      Where do I find documentation on the 3300ACM?

      Issue
      Customer looking for documentation on 3300 ACM meter

      Product Line
      3300 ACM

      Resolution
      The document titled, 3300_Installation_and_Operation_Manual.pdf, contains the full installation and user guide for the 3300ACM meter. This document also includes the PML register list in the appendix. The Modbus register list is available in the document titled, 3300_ACM_Modbus_Protocol.pdf.

      What is the part code for a Clipsal metal range 12 Gang Switch Assembly (Less Mechanisms) - Stainless Steel?

      B12/30/6 = 12-Gang Switch Plate. 2 rows of 6. Stainless steel. 303mm 120mm
      12/30/162/3 = 12-Gang Switch Plate. 4 rows of 3. Stainless steel. 165mm 215mm

      Includes stainless steel fascia with grid and wall box. Standard grid colours - White Electric (WE) and Black (BK).
       

      Can I get a 30USM with a red dot on the dolly?

      Yes, you can get a 30USM with a red dot. The part number is 30USMRD.

      Some of the key features are:
      • Reduced visible arcing and crackling
      • Modular 30 mech design suits most Clipsal switch plates
      • With Red Dolly dot
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USMRD


       

      Can the 30USM be used for Fluro loads?

      Yes , it is rated to 16AX for fluro based loads.

      Is a 30USM-WE a normal switch rocker mechanism

      30USM-WE = Universal switch mechanism 20/16AX - compared to the 10A only 30M-WE
      (see attached 30USM Brochure)

      What is the size of the terminal screws in the Clipsal 30USM mech?

      Screw B.S M3.5 X 0.6, 5.6mm CH HD IN

       

      Is a 16amp mech available marked 'Heat'?

      Part number replaced with 30USM mech but marked 'Heat' is not standard.
       

      Is there a way to block off my 300mm exhaust fan when not in use?

      Yes, you can use a Draftstoppa. The part number is CEDS1.

      Some of the key features are:
      • Draftstoppa prevents heating / cooling escaping through all non-operating domestic ceiling exhausts up to 300 mm.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=CEDS1.
       

      Can you wire an over ride into a 2 wire 750WP?

      Yes. In order to get the system to work, you will need to wire in either 2x 30M's or a 30MAM into a wall plate and connect to the sensor.

      For further information on the sensor, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=750WP

      User-added image

      I am looking for a wall fan with a 240mm cutout and is physically approx 300mm square

      You can use a Clipsal 7106A or 7108A both have a 230mm cut out and are 271mm square

      I need a Saturn range mech and a telephone mech, what part's do I need

      If you want 2 stove switches in one plate, you would need to use Clipsal 4032VH and 30M35 and for the telephone use a 30BTM and 4031VH

      What is the replacement for the 30FLM?

      The replacement for the 30FLM is the 30USM.

      Some of the key features are:
      • Reduced visible arcing and crackling
      • Modular 30 mech design suits most Clipsal switch plates
      • Ability to switch fluorescent loads up to 16 AX

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM

       

      Is it possible to upgrade the firmware in an 3720 ACM?

      Product Line
      3720 ACM

      Environment
      Firmware

      Resolution
      The firmware upgrade process for a 3720 ACM required an EEPROM chip with the firmware loaded, to be inserted into the meter. These chips are no longer available.

      Errata to the 3720 ACM Installation & Operation Manual

      Issue
      Documentation is needed for the 3720 ACM series meter.

      Product Line
      3720 ACM

      Environment
      3720 ACM

      Cause
      Documentation is needed for the 3720 ACM series meter.

      Resolution
      The Errata page for 3720 ACM Installation & Operation Manual is attached.

      3720 ACM MPCC/MPE Retrofit Installation Instructions

      Issue
      Documentation is needed for the 3720 ACM series meter.

      Product Line
      3720 ACM

      Environment
      3720 ACM

      Cause
      Documentation is needed for the 3720 ACM series meter.

      Resolution
      The MPCC/MPE (communication card) Retrofit Installation document is attached.

      What is the part number for a replacement key for the 30TKM?

      The part number for a replacement key for the 30TKM is - 30TKM KEY
      For further information , visit link below:
      https://www.clipsal.com/Trade/search-results?q=30TKM%20KEY
      User-added image
       

      What is the part number of a F type front / F type rear TV socket in 30 series?

      30PFM is a TV Antenna Socket 75 Ohm - F-type front / F-type rear, suits PAY TV, IR pass through.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PFM
      ​​

      How many dimmers can I fit in to a BSL plate.

      You can put a maximum of 3 dimmers in a grid plate.  You will need to order BSL36VH + 3 x 30USM + 3 x whichever dimmer is appropriate for your lighting

      Does the WS229 come with push button mech?

      The WS229 comes with a 30USM as standard.
      A push button mech will need to be incorporated into a WS229VH.


       
      Show More