Grid Switch Vert/Horiz 5G

Clipsal Iconic - Switch Grid, Vertical/Horizontal Mount, 5 Gang

Catalogue Number: 3045G
Grid Switch Vert/Horiz 5G
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Clipsal Iconic
Product or component type
fixing frame
Aesthetic name
Iconic
Number of gangs
5 gangs
Fixing mode
by screws
Range compatibility
cover plate
Provided equipment
screws
Depth
12 mm
Width
71 mm
Height
115 mm
Net weight
0.044 kg
Type of packing
polybag
EU RoHS Directive
Under investigation
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Environmental

Frequently Asked Questions

hide show

What is the part number for a 6 gang switch for the Iconic range?

The part number for a 6 gang switch for the Iconic range is - 3046G & 3046C

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3046G
https://www.clipsal.com/Trade/search-results?q=3046C
User-added image

User-added image

 

Is Iconic intermediate mechanism available assembled on a switch plate?

Unfortunately, the Iconic intermediate mechanism is not available assembled on a plate. It can put together using below part numbers;
40MIL  - Clipsal Iconic Intermediate Switch Mechanism, 250V, 10A, LED.
+
3041G - Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang
+
3041C - Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang
For further information, please visit the below links:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MIL
https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G
https://www.clipsal.com/Trade/search-results?q=3041C


What are the part numbers to make up a 4 gang switch with LED for the Iconic range?

The part numbers to make up a 4 gang switch with LED for the Iconic range are - 3044G , 40ML & 3044C

For further information visit links below:-
https://www.clipsal.com/Trade/search-results?q=3044G
https://www.clipsal.com/Trade/search-results?q=40ML
https://www.clipsal.com/Trade/search-results?q=3044C
User-added image

What is the part number for Iconic foxtel TV outlet?

The part numbers for Iconic Foxtel TV outlet are 3041G + 3041C-** + 40PFM-TN

3041G Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang

3041C-WY Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang

Clipsal Iconic - TV Antenna Socket, 75 Ohm, F-Type

For further information see:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-WYhttps://www.clipsal.com/Trade/search-results?q=40PFM
 

What part numbers are needed to put together an Iconic 1 gang electronic Pushbutton switch plate (Vivid white)?

Below are the part numbers needed to put together an Iconic 1 gang electronic Pushbutton switch plate :

3041G - Clipsal Iconic - Switch Grid, Vertical/Horizontal Mount, 1 Gang
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G

+

3041C-VW -Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang, Vivid White
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-VW​

+
41E350PBES2SM-VW -Clipsal Iconic - Electronic Switch Mechanism, Push Button with ControlLink (without bluetooth) 2-wire, 350W
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=41E350PBES2SM

Do the switches in Iconic switched socket outlet have LED indicators, example 3025?

There are no LED indicators on the switches in Iconic switched socket outlet. The switches on the outlet have green markings so you know when it is switched ON.

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3025



 

Will a LV432455 Vigi add on fit to a NS630H MCCB?

A LV432455 Vigi add on will not fit a NS630H MCCB only a 32455 will fit otherwise will need to change MCCB to LV432895.
 

What is the part number for the ICONIC night walk?

The part number for the ICONIC night walk is a 3025NW. which is only the cover/sensor light. You will also need the grid which is a 3025G.

What is the part number of the fixed Front Connection snap-in nuts for the Compact NS100 to 630 circuit-breakers.?

The part number of a set of 12 fixed front connection snap-in nuts is:

29234 for Compact NS100.
30554 for Compact NS160... 250.

These parts are not available for Compact NS400 to 630.

What is the part number for Iconic 3 gang grid and cover assembly (less mechanisms)?

In the Iconic range, switch grid and skin(cover) are sold separately.
Part number of the 3 gang switch grid is 3043G. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3043G
Part number of the skin is 3043C. Skins are available in Vivid White(VW), Warm White(WY), Cool Grey(CY) and Anthracite(AN). 
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3043C-WY


 

M580 SD memory card format procedure

M580 CPU SD memory card format procedure
  1. Connect to M580 and make sure the Unity project is “Equal”, “Run” and “Built”
  2. Stop the PLC
  3. Open SD card door and make sure LED is ON
  4. Open the “Animation Table” Window
  5. Add system word %SW93.0 and %SW93.1
  6. Turn on the “Modification” button
  7. Enter value “1” for %SW93.0
  8. (This will start the format of the SD card then that value will change back to “0” and the value of %SW93.1 will go from “0” to “1” to indicate the format has completed successfully), (Formatting a standard SD card takes about 30-50 seconds)
  9. When completed enter value of “0” for both %SW93.0 and %SW93.1
  10. Start PLC

How Does Tenant Metering Software Commercial Edition (TMSCE) Calculate 15, 30, or 60 Minute Rolling Demand?

If the data is collected on a 15 minute interval, there is no difference between rolling demand and present demand. Data that is collected on a 5 minute interval is the average of the current interval and the previous two. For example, if the data is measure at 2:00, 2:05, 2:10, 2:15, 2:20, 2:25, and 2:30, the rolling demand for 2:20 would be the average of the readings taken at 2:10, 2:15, and 2:20.
With 15 minute interval data, the 30 minute rolling demand is calculated by averaging the previous demand interval with the current one. For example, data is taken at 2:00, 2:15, 2:30, 2:45, and 3:00. The 30 minute rolling demand for 2:45 is the average of the demand readings at 2:30 and 2:45.

With 15 minute interval data, the 60 minute rolling demand is calculated by averating the current demand interval with the previous three. For example, data is taken at 2:00, 2:15, 2:30, 2:45, 3:00, 3:15, 3:30, and 3:45. The 60 minute rolling demand for 3:15 is the average of the demand readings at 2:30, 2:45, 3:00, and 3:15.


Legacy KB System (APS) Data: RESL198518 V1.0, Originally authored by AnVa on 05/16/2009, Last Edited by AnVa on 05/16/2009
Related ranges: Tenant Metering Software

How is MTBF (Mean Time Between Failures) Calculated?

Goals and Symptoms:

How is MTBF (Mean Time Between Failures) Calculated?

Causes and Fixes:

How is MTBF (Mean Time Between Failures) Calculated?

1. Computed following RDF2000 Reliability model (UTE C 80-810 standard) - EQUIPMENT ambient temperature at 30deg C (86deg F), 60deg C (140deg F) and 85deg C (185deg F)
  • 2. Continuous operation profile: 100% operation rate per year (365d / year, 24h / day) - 12 power on/off per year (1 per month) - No stocking days
  • 3. Intermittent operation profile: 46% operation rate per year (335d / year 12h /day) - 335 power on/off per year (1 per operating day) 30 stocking days
  • 4. MTBF are given in hours

Why does my Rack ATS (AP77XX) lose SNMPv1 communication with my StruXureWare device or ISX Manager?



Issue

My Rack ATS (AP77XX) is losing SNMPv1 communication with my StruXureWare device, ISX Manager, or other SNMP NMS periodically.


Product Line
 
  • Only the following Rack Automatic Transfer Switch (ATS) models:
    • AP7752
    • AP7753
    • AP7721
    • AP7723
    • AP7724
    • AP7730
    • AP7732

Environment
 
  • All serial numbers
  • Rack ATS app g2ats v3.5.7 and below
  • Rack ATS monitored by the SNMPv1 protocol


Cause

An issue has been previously indentified with the aforementioned Next Generation Rack ATS product firmware that causes the device to lose SNMPv1 communication with StruXureWare, ISX Manager, or other SNMP monitoring programs. This issue occurs after an undefined amount of uptime but limiting access control to specific devices seems to help increase the uptime to about 30-45 days for the integrated Network Management Card.


Resolution


This has been addressed in Rack ATS Firmware g2ats v3.7.0 and higher. If you are unable to update to v3.7.0 or higher from https://www.apc.com/tools/download/index.cfm, a warmstart of the Network Management Card Interface is required to re-establish communication. This can be accomplished by pushing the "Reset" button on the front of the ATS or issuing the Reboot Management Interface from the Network Management Card UI (web, telnet/SSH, or local console). This action does not disrupt power output of the ATS and only reboots the Management Interface.


 

What is the part number for the grid only in the Iconic range double gpo ?

The grid 3025VXUAG is suitable for both the 3025V and 3025VXA setup ( the 2 units share a common grid )