Switch Vert IP44 2G 1/2way 10AX 250V VW

Switch Vertical 2G 1/2 Way 10AX 250V IP44

Catalogue Number: 3042V44
Switch Vert IP44 2G 1/2way 10AX 250V VW
Colour: Vivid White
Colour: Per UOM Std.
  • Vivid White 1 PCE
Added to cart

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switch
Device application
lighting
Colour tint
vivid white
Quantity per set
set of 20
Device presentation
complete product
Control type
rocker
Device mounting
flush
Installation direction
vertical
Switch function
1-pole 1-way
Number of rocker
2
Rated current
10 A
[Ue] rated operational voltage
250 V
Material
plastic
Height
124 mm
Width
82 mm
Depth
40 mm
Net weight
0.098 kg
IP degree of protection
IP44
EU RoHS Directive
Under investigation
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Does part number 3044V44 available in Cool Grey?

Part number comes standard as Vivid White, will need Cool Grey cover to suit.
 

What is the maximum voltage ratings for the contacts of a CA2KN?

Issue:
What is the maximum voltage ratings for a CA2KN22F7?

Product Line:
Relays and Timers

Environment:
Industrial Relays

Resolution:
600VAC and 240VDC

Is a 9001KY3 available with an extra conduit entry in the top?

Issue:
Is a 9001KY3 available with an extra conduit entry in the top?
Product Line:
30mm Enclosures
Environment:
9001KY/SKY Control Stations
Cause:
Need clarification before control station is installed.                        
Resolution:                                                                 
No, the 9001KY enclosures have a bottom conduit opening standard. Extra conduit openings are not available.
 

What is the replacement part for the trip unit interlock of a Masterpact NW breaker?

Issue:
Broke the white trip unit interlock behind the trip unit.  Masterpact NW. NW breaker trips when it OPENS and red button pops out but no Ap light comes on.  Does not trip when it closes.

Product Line:
Masterpact NW

Environment:
Masterpact NW Circuit Breaker

Cause:
Repair parts

Resolution:
Replace the trip unit base, part# 47947. This part is available only to Square D / Schneider Electric Field Services and they must do the installation.


 

What is the difference between a two speed single winding and two speed two winding starter?

Issue:
What is the difference between a two speed single winding and two speed two winding starter?

Product Line:
8810 Multispeed Magnetic Starters

Environment:
Products sold and used in the United States

Cause:
Selecting a two speed starter

Resolution:

Multispeed motors are available in two basic versions:

1) separate winding, and 2) consequent pole. A separate winding motor has a winding

for each speed while a consequent pole motor has a winding for every two speeds

(three-speed motors have two windings). The motor connections (and thus the types of

controllers) for two speed starters are exemplified by the schematic diagrams shown in

Table 16.22. Note that consequent pole two-speed controllers involve a 5-pole and a 3-

pole starter, while separate winding controllers have two 3-pole starters.

Verify the type of motor before ordering. Field modification of starters to match the

motor may not

be possible.

Separate winding motors are usually chosen when flexibility is important, since the

speeds of a consequent pole motor are usually limited to a 2/1 ratio; a broad range of

speeds can be obtained on a separate winding motor.

Both separate winding and consequent pole motors are available in three types:

1) constant horsepower, 2) constant torque, and 3) variable torque. Table 16.21 shows

typical applications for these different types of motors.

NOTE: For detailed information involving the technical aspects


 

Will the Compact NSX breaker be for sale in the USA or Canada?

Issue:
Where can I buy a Compact NSX breaker?

Product Line:
Circuit Breakers

Cause:
This breaker is popular overseas and there is interest in the US

Resolution:
There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page