Grid Socket Horiz Single 20A 250V

Clipsal Iconic - Grid Socket Horizontal Single 20A 250V

Catalogue Number: 3015/20G
Grid Socket Horiz Single 20A 250V
Retail
$55.69*
RRP (Inc. GST)

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switched socket
Device presentation
mechanism with fixing frame
Outlet poles configuration
2P + E
Device mounting
flush
Number of power socket outlets
1
Number of rocker
1
Range compatibility
cover frame
Outlet standard
Australian
Outlet standard description
with earthing contact
Outlet standard
Australian/New Zealand
Ground lug position
straight 180° position
Fixing mode
by screw
Installation direction
horizontal
Surface finish
matt
Type of packing
polybag
Quantity per set
set of 10
Sale per indivisible quantity
1
Rated current
20 A at 250 V AC 50 Hz
Electrical durability
9000 cycles
Connections - terminals
3 screw terminals
Screwdriver shape
  • square drive no 1 (SQ1)
  • Philips No 2
    • Clamping connection capacity
    • 1 x 2.5...4 x 2.5 mm² for rigid cable(s)
    • 1 x 2.5...4 x 2.5 mm² for stranded cable(s)
    • 1 x 2.5...4 x 2.5 mm² for flexible cable(s)
      • Wire stripping length
        16 mm
        Material
      • PC (polycarbonate): fixing frame
      • PP (polypropylene): rocker
        • Height
          71 mm
          Width
          115 mm
          Depth
          26 mm
          Embedding depth
          23 mm
          Net weight
          0.82 kg
          Ambient air temperature for operation
          0-45 °C
          Relative humidity
          10-95 %
          Standards
          AS/NZS 3112
          Product certifications
          RCM
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
           Pro-active China RoHS declaration (out of China RoHS legal scope)
          Environmental Disclosure
          ENVPEP120506EN

          Frequently Asked Questions

          hide show

          What is the cover for a C2015/20?

          The cover for a C2015/20 is a C2015/20C.

          Do Clipsal make a 3 pin, 20 amp, switched outlet with flat pins?

          Yes, 20A 3 flat pin switched outlets are available in a few variants , most commonly the 2015/20, C2015/20 and 56C320F.

          For further information please visit:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015/20
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015/20
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C320F

           

          What is part number for Stainless Steel cover to suit C2015/20?

          The part number for Stainless Steel cover to suit is a C2015/20C.

          Is part number C2015/20 available in Red?

          Yes it is and the part number is C2015/20-RD.

          What is the difference between AS3112 and AS3123?

          AS3112 is used for standard 3 pin 10/15/20A sockets, AS3123 is for three phase round pin sockets.

          Is the 801/20R retractable lead still available?

          This retractable lead is no longer in our product range and there is no alternative available.

          Do we have a replacement for retractable cabel reel 801/20R?

          No. Unfortunately, 801/20R is discontinued and there is no replacement.

          Do you have a bracket for the 3015/4?

          Yes, you would use the 3155H4.

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3155H4

          What is the mounting bracket to suit part number 3015/4?

          The part number is 3155H4 at this stage anticipated release is December 2016.

          What is part number for Iconic cover to suit 3015/4?

          The part number for Iconic cover to suit is 3015/4C.

          Are there double GPO's that are individually wired on each side?

          Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

          ENM 8.2 not sending alarms : Event Gathering Service was unable to find either PSE or PME on target host.

          Issue
          ENM does not process alarms or emails

          Product Line:
          Power monitoring expert 8.2
          ENM 8.3

          Environment
          Energy monitoring 

          Cause
          Upon opening the diagnostic screen for ENM an error appears in the log

          Event Gathering Service was unable to find either PSE or PME on target host.

          HandlingInstanceID: 1b319608-2529-4843-8107-97dcc899e01e An exception of type 'Utility.UpdateEfSourcesException' occurred and was caught. -------------------------------------------------------------------------------- 03/15/2018 08:52:30 Type : Utility.UpdateEfSourcesException, Utility, Version=1.0.14188.0, Culture=neutral, PublicKeyToken=null Message : Unable to Update EF Sources Source : Module.EFSourceSave Help link : Data : System.Collections.ListDictionaryInternal TargetSite : Boolean Update() HResult : -2146233088 Stack Trace : at Module.UpdateEFSources.Update() at Components.UIEndpointHost.<.ctor>b__5(Object u) Additional Info: MachineName : FPM12 TimeStamp : 3/15/2018 1:52:30 PM FullName : Microsoft.Practices.EnterpriseLibrary.ExceptionHandling, Version=2.0.0.0, Culture=neutral, PublicKeyToken=null AppDomainName : SEEGS.exe ThreadIdentity : WindowsIdentity : NT AUTHORITY\SYSTEM Inner Exception --------------- Type : System.ArgumentNullException, mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089 Message : Value cannot be null. Parameter name: source Source : System.Core Help link : ParamName : source Data : System.Collections.ListDictionaryInternal TargetSite : System.Collections.Generic.IEnumerable`1[TResult] Select[TSource,TResult](System.Collections.Generic.IEnumerable`1[TSource], System.Func`2[TSource,TResult]) HResult : -2147467261 Stack Trace : at System.Linq.Enumerable.Select[TSource,

          Resolution
          If PME is upgraded to 8.2 then ENM would need to be upgraded to function properly. 
          PME 8.2 requires ENM 8.3.3 to be installed. 

          Run the ENM installer located on the PME 8.2 disk to install ENM 8.3.3 to restore alarms and email processing. 

          PME 8.2 Download

          Software Compatability Matrix