Socket Sw Horiz Single 10A 250V VW

Clipsal Iconic - Single Switch Socket Outlet, Horizontal Mount, 250V, 10A

Catalogue Number: 3015
Socket Sw Horiz Single 10A 250V VW
Colour: Vivid White
Colour: Per UOM Std.
  • Vivid White 1 PCE

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switched socket
Device presentation
complete product
Outlet poles configuration
2P + E with shutter
Device mounting
flush
Number of power socket outlets
1
Number of rocker
1
Range compatibility
Outlet standard
Australian
Outlet standard description
with earthing contact
Outlet standard
Australian/New Zealand
Ground lug position
straight 180° position
Fixing mode
by screw
Installation direction
horizontal
Colour tint
vivid white (VW)
Surface finish
matt
Type of packing
polybag
Quantity per set
set of 10
Sale per indivisible quantity
1
Rated current
10 A at 250 V AC 50 Hz
Electrical durability
12000 cycles
Connections - terminals
3 screw terminals
Screwdriver shape
  • square drive no 1 (SQ1)
  • Philips No 2
    • Clamping connection capacity
    • 1 x 2.5...4 x 2.5 mm² for rigid cable(s)
    • 1 x 2.5...4 x 2.5 mm² for stranded cable(s)
    • 1 x 2.5...4 x 2.5 mm² for flexible cable(s)
      • Wire stripping length
        16 mm
        Material
      • PC (polycarbonate): fixing frame
      • PP (polypropylene): rocker
      • POM (polyoxymethylene): shutter
      • PC (polycarbonate): cover frame
      • ABS (acrylonitrile butadiene-styrene): cover frame
        • Height
          78 mm
          Width
          120 mm
          Depth
          31 mm
          Embedding depth
          24 mm
          Net weight
          0.1 kg
          Ambient air temperature for operation
          0-45 °C
          Relative humidity
          10-95 %
          Standards
          AS/NZS 3112
          Product certifications
          RCM
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Environmental Disclosure
          ENVPEP120506EN
          Circularity Profile
          N/A

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Technical Leaflet

          • Product Environmental

          • Installation Instruction

          • Operating Manuals

          • Certificates (MSDS)

          Frequently Asked Questions

          hide show

          What is screwdriver head size for Iconic 3025 GPO?

          The screwdriver head size for Iconic 3025 GPO is either size PH2 or SH1 can be used.

          Do you have an Iconic outlet with round earth?

          No, we do not have a 3015 with a round earth pin.

          For further information please visit https://www.clipsal.com/Trade



           

          What registers hold the serial number for the Series 3000, 4000 Circuit Monitor and Series 800 Power Meter?

          Register 3017 and 3018 contain the serial number for each meter. To calculate the serial number read the values as hexadecimal, put the numbers together and convert to decimal.


          • Example: Register 3017 = D93E

            Register 3018 = A7

            Serial # in Hex = A7D93E

            Convert to Decimal Serial Number = 11000126

             


            Original article#
            Date Created: April 23, 2007
            Last Revised: January 25, 2008
            Public
            Original Author: RM
            All content © 1992-2008 Schneider Electric


          Legacy KB System (APS) Data: RESL190841 V1.0, Originally authored by PhHa on 01/29/2008, Last Edited by PhHa on 01/29/2008
          Related ranges: PM800 series, CM4000 series, CM3000 series

          what is the part number for cover for the 4015?

          The part number for cover for the 4015 is 4015C
          For further information, please visit:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=4015C

          User-added image

          Are EasyPact CVS circuit breakers for sale in the USA or Canada?

          Product Line:
          EasyPact CVS circuit breakers

          Cause:
          This breaker is popular overseas and there is interest in the US

          Resolution:
          There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

          Do the Saturn switched socket plates come in vertical?

          No, this range of sockets is only available in horizontal, including the Horizon and Zen ranges

          What is the replacement knob for a 9001K joysticks?

          Issue:
          Needs part number for replacement knob of 9001K joystick without latch

          Product Line:
          Type K Heavy Duty Specialty Operators

          Environment:
          North American Products

          Resolution:
          The replacement knob for a 9001K joysticks ``without latch`` is 4458D20X3.
           

          What is the replacement for part number 30M15?

          The replacement for part number 30M15 is 30USM. 30USM is an universal rocker mechanism rated to 20A / 16AX, 250V, 1 way / 2 way.
          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM
          User-added image

          What UnityPLCUSB driver works with Windows 10?

          Issue
          PLCUSB driver will not work on Windows 10 without error.  

          Product line
          Unity, M340, M580 and Quantum.

          Resolution
          As of Jan 28, 2019, the latest Unity PLCUSB driver for Windows10 is version 3.15 IE25 (released Mar 2018).
           

          Is there a Saturn 4015 with extra switch available?

          No, unfortunately there isn't a single outlet with extra switch available in the Saturn 4000 Series. 

          You can get a double outlet with an extra switch. The part number is 4025XA.

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025XA.

           

           

          What is the part number for cat 5 cable in 305 mtr roll?

          The part number is 2D4P5IPV3B

          Please click this link for more information
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=2D4P5IPV3B

          User-added image

          Can the Energy Meter be mounted more than 20 feet from the CTs?

          Product line
          Energy Meters (EMB and EME series)

          Environment
          Energy Meter Installation

          Resolution
          The energy meters have been tested and verified functionality with the CTs mounted up to a maximum distance of 300 feet from the meter using 18 AWG twisted leads with 600V insulation (UL 1015 or equivalent).

          What is the part number of white 2015 switched single 2000 series outlet with red dolly/mechanism ?

          2015RDL-WE is the part number of the white 2015 switched single 2000 series outlet with red dolly/mechanism.
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015RDL

           

          Lock for old Prisma beige cabinet?

          Support and spare parts for Prisma beige ended December 2015

          What is the length of the shaft in the GV3APN02 kit?

           The shaft included in the GV3APN02 kit is a GVAPA1. It has a length of 315 mm.
           

          Where can I find the register list for the iEM3100, iEM3200, and iEM3300 series of meters?

          Issue
          A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
           
          Product Line
          iEM3100, iEM3200, iEM3300 series
           
          Environment
          iEM3100, iEM3200, iEM3300 series
           
          Cause
          A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
           
          Resolution
          The user manual for the iEM3100, iEM3200, and iEM3300 series of meters (document reference number DOCA0005EN-04) has a register list in Chapter 5: Communications via Modbus RS-485. See page 57 of the pdf document attached   (doca0005en-04.pdf)

          What is the part no for a 2015 with mech style ID in Blue color?

          The part no will be the medilec version

          Ml2015I-DB (dark blue)

          This is the link to the page https://www.clipsal.com/trade/products/ProductDetail?CatNo=ML2015I

          User-added image

          What is the part number for cat 6A shielded cable?

          The part number for the shielded 4 pair FUTP CAT6A LAN cable, LSZH, 305 metre reel is 2D4P6ALSF3R-BU.

          ClearSCADA: WebX upgrade in ClearSCADA 2015 R1, 2015 R2 and 2017

          ClearSCADA's new WebX server installs differently depending on the version of ClearSCADA that you have:

           Background

          Starting with ClearSCADA 2015 R1, a new WebX server has been included in the ClearSCADA software package along with the original WebX client.  This new WebX server utilizes the Internet Information Services Manager (IIS) in order to facilitate its connection.  ClearSCADA users may choose to view WebX by way of either the original WebX client or by way of a WebX client connection to the new WebX server.



          ClearSCADA 2015 R1 featured ClearSCADA Mobile and the new WebX bundled into a single feature. Bundling them together was found to be less flexible and reliable as opposed to having these features separated. 

          ClearSCADA 2015 R2 had both ClearSCADA Mobile and the new WebX separated, however the Mobile Companion still had to be tied to a Web server. Hence it was actually tied to the old Web server components and was installed along with it. This would be why it was not in the list as a separate feature in 2015 R2 (Control Panel | Programs and Features).

          Starting from ClearSCADA 2017 the total separation of the two components was completed and the new WebX started to appear as a separate feature (in Control Panel | Programs and Features).


          Installation

          Prior to ClearSCADA 2015 R1, WebX installed quietly as part of the standard ClearSCADA installation (full or standard installation).

          Starting with ClearSCADA 2015 R1, the installer runs through the installation of most of the ClearSCADA components first, then it runs through the installation of the new WebX component.  The user is prompted to install the new WebX upon completion of the installation of the other ClearSCADA components (CS server, data access components, ViewX, etc).

          A user simply needs to start the installation process by selecting the "Install ClearSCADA " option from the splash screen (valid for ClearSCADA 2015 R1, ClearSCADA 2015 R2 and ClearSCADA 2017).  These screens look as follows:





          Starting with ClearSCADA 2017 R2, the new WebX component installation has been moved to its own installer.  This is covered in a separate knowledge base article; FA366071 ClearSCADA: Configuring the new WebX in ClearSCADA 2017 R2.

          How Does Tenant Metering Software Commercial Edition (TMSCE) Calculate 15, 30, or 60 Minute Rolling Demand?

          If the data is collected on a 15 minute interval, there is no difference between rolling demand and present demand. Data that is collected on a 5 minute interval is the average of the current interval and the previous two. For example, if the data is measure at 2:00, 2:05, 2:10, 2:15, 2:20, 2:25, and 2:30, the rolling demand for 2:20 would be the average of the readings taken at 2:10, 2:15, and 2:20.
          With 15 minute interval data, the 30 minute rolling demand is calculated by averaging the previous demand interval with the current one. For example, data is taken at 2:00, 2:15, 2:30, 2:45, and 3:00. The 30 minute rolling demand for 2:45 is the average of the demand readings at 2:30 and 2:45.

          With 15 minute interval data, the 60 minute rolling demand is calculated by averating the current demand interval with the previous three. For example, data is taken at 2:00, 2:15, 2:30, 2:45, 3:00, 3:15, 3:30, and 3:45. The 60 minute rolling demand for 3:15 is the average of the demand readings at 2:30, 2:45, 3:00, and 3:15.


          Legacy KB System (APS) Data: RESL198518 V1.0, Originally authored by AnVa on 05/16/2009, Last Edited by AnVa on 05/16/2009
          Related ranges: Tenant Metering Software

          Does Clipsal sell Cat6 cable suitable for underground application?

          No. Unfortunately, Clipsal does not have a Cat 6 cable suitable for underground application. Clipsal Cat6 cable 2D4P6IPV3B is suitable for above ground indoor horizontal LAN cabling situations. It is supplied in 305 metre box.
          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2D4P6IPV3B
          User-added image

          Can i get a 2015 with an ID label in red?

          To create this part you will need a 2015XUA-RD and a 30PID-RD. Please note you will need to assemble this unit yourself.
          Some of the key features are:
          • Removable extra switch with aperture
          • 2000 Sereis
          • 10A
          • 250V
          • Single Outlet
          • Various colours available
          For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=2015XUA

          Catalogue pages of the obsolete XUSLT type 4 safety light curtains

          Please find attached the catalogue pages of the obsolete XUSLT type 4 safety light curtains.

          User manual of the obsolete XUSLT type 4 safety light curtains

          Please find attached the user manual of the obsolete XUSLT type 4 safety light curtains.

          User manual of the obsolete XUSLA/C type 4 safety light curtains

          Please find attached the user manual of the obsolete XUSLA/C type 4 safety light curtains.

          User manual of the obsolete XUSLN type 2 safety light curtains

          Please find attached the user manual of the obsolete XUSLN type 2 safety light curtains

          User manual of the obsolete XUSLB/DM type 4 safety light curtains

          Please find attached the user manual of the obsolete XUSLB/DM type 4 safety light curtains, for finger and hand protection

          Can you put a 642MUSB USB mech into a double socket plate, eg 695X ?

          Yes as of December 2015 the 642MUSB mech can be installed into the extra mech position of the 692X or 695X
          This is also available as complete units:
          PDL695USBWH
          PDL692USBWH

          Osisense XS_Obsolete XS1M12PAW01D inductive sensor cross-reference

          The obsolete XS1M12PAW01D inductive sensor is replaced in 2015 by the XS912RWPAM12 one. Attached corresponding datasheet.

          Video: How do I properly reset a Symmetra XR Frame Communications Card (SYXRCC or SYAFSU16)?

          Issue
          SYXRCC or SYAFSU16 must be reseated in order to reset communication for routine troubleshooting; what is the proper procedure?

          Product Line
          Symmetra Power Array
          Symmetra RM
          Symmetra LX

          Environment
          All models

          Cause
          The XR frame shows a fault or the user is troubleshooting an issue which may be related to the XR frame.

          Resolution
          Please follow the below steps in resetting the communication card on the Symmetra Extended Run Frame. This can be done while the system is live. 

          1) Disconnect the communication cable(s) in the card  located in the back of the Symmetra Extended Run Battery Frame and wait for the green status light to go off.

          2) Turn off the communications card by unscrewing the thumbscrews on the card so that the micro-latch that is being held by one of the thumbscrews is unseated.

          3) Reseat the micro-latch on the card and screw in the thumbscrew back into the top right-hand corner of the card.

          4) Reconnect the communication cable(s) in the back of the card and acknowledge the return of the green status light within 60 seconds the UPS will re recognize the additional batteries and adjust the runtime value accordingly to include the batteries located in the Extended Run Frame.

          The following video demonstrates the procedure of reseating and installing the Symmetra XR Communications Card:

           

          How to upgrade ClearSCADA Mobile?

          ClearSCADA Mobile installs differently depending on the version of ClearSCADA that is being used:

          ClearSCADA 2015 R1 featured ClearSCADA Mobile and WebX bundled into a single feature.

          ClearSCADA 2015 R2 had both ClearSCADA Mobile and WebX separated, however, the Mobile Companion still had to be tied to a Web server.  Hence it was actually tied to the old We server components and was installed along with it.

          Starting from ClearSCADA 2017, the total separation of the two components (ClearSCADA Mobile and WebX) was completed.

          ClearSCADA Mobile needs to be upgraded after an upgrade of ClearSCADA takes place. To upgrade ClearSCADA Mobile, the following steps need to be followed:

          Upgrading from ClearSCADA Mobile 2015 R1 to ClearSCADA Mobile 2015 R2
          1. Make a backup of your existing Mobile configuration by making a copy of the "MobileConfig.sdf" file located in "C:\ProgramData\Schneider Electric\ClearSCADA Mobile"
            • This file contains the license information and configuration of the systems and devices
            • Keep a copy of this file in a different location in case it is needed
          2. Uninstall the existing version ClearSCADA Mobile from Windows Control Panel -> Programs and Features
            • Please note that your Mobile configuration should stay untouched even after removing ClearSCADA Mobile as long as the MobileConfig.sdf file is present at the original location
          3. Launch Microsoft Internet Information Services Manager and make sure that "ClearScadaMobile" site is not present
            • If the site is still present after uninstalling ClearSCADA Mobile, remove it manually by right clicking on it and selecting "Remove"
            • Please note that if you are upgrading from ClearSCADA 2015 R1, the mobile site is a part of the "ClearSCADA" site
          4. Launch ClearSCADA installer and select "Install ClearSCADA Mobile" to install the new version of the software and follow the installation steps
          5. Once installed, launch ClearSCADA Mobile Configuration to make sure your original configuration is still present

          Upgrading from ClearSCADA Mobile 2015 R2 or newer

          The above steps do not need to be followed when upgrading ClearSCADA Mobile from version 2015 R2 or newer (i.e. 2017, 2017 R2).  Simply run the installer from the splash screen as shown in the screen shot below


          Is it possible to change how Lexium 23 responds to alarm 014 or alarm 015 when reaching the end of travel limit switches?

          Reaching end of travel limit switches will always result in a stop of motion and the respective alarm code being displayed.
          This behavior is firmware related and can not be modified.
          There are no provisions to change this behavior.

          When Lexium 23 reaches the end of travel limit swiches it responds by stopping motion and displaying alarm 014 or alarm 015, depending on the direction of travel when reaching the limit switch.
          To recover from this event you must reset the alarm and then create movement in the opposite direction of the limit switch that has been reached.


           

          For the BCPM product, what is the LVCT burden (or the apparent power capacity)?

          Product Line
          BCPM, the LVCT (Low Voltage Current Transformer)

          Environment
          Low Voltage Current Transformer Specification

          Resolution
          The BCPM uses 1/3 V output split-core CTs for the auxiliary inputs
          The 1/3 Volt low-voltage CT specifications are:
          Accuracy: 1% from 10% to 100% of rated current
          Frequency range: 50/60 Hz
          Operating temperature Range: -15° C - 60° C
          Storage temperature Range: -40° C - 70°C
          Humidity range: 0 - 95% non-condensing
          Leads: 18 AWG, 600 Vac, UL 1015 twisted pair, 1.8m standard length
          Max. Voltage L-N: sensed conductor 600 Vac

          The apparent power capacity (or burden rating) doesn't really apply since these are voltage output devices (rather than current mode like traditional Current Transformers). This is one of the great advantages of voltage mode CT (the other being they don't need shorting blocks). The voltage mode CT has an internal burden resistor, usually tens of ohms or less. The input of the meter monitoring the voltage mode CT typically has an input impedance of tens of thousands of ohms or more in parallel with the CTs burden resistor (which can reduce the CTs output voltage very slightly). As long as the series resistance of the wire between the voltage mode CT and the meter is less than hundreds of ohms, the accuracy of the CT will be little affected. Voltage mode CT can drive a much longer wire run using smaller gauge wire than a traditional current mode CT.

           

          Video: Why can I not connect via USB to my M580 with Unity Pro?

          Issue:
          Unity Pro is unable to establish a USB connection with a Momentum and an M580.

          Product Line:
          Momentum
          M580

          Environment:
          Unity Pro

          Resolution:
          There is a common USB connection issue with the M580 where it will not allow you to connect because it does not see the controller. Not all users will experience this issue and there is a work around. If you are not able to connect, first and foremost, you must make sure that you have a healthy USB connection and that you have the PLC USB drivers installed. If all that checks out you may need to change the IP Address of the M580's network adapter. The M580 USB driver installs an unidentified Ethernet network adaptor named SE RNDIS PSX M580 Connection that can be seen when the USB connection is made between the PC and M580. 
          To change the IP Address navigate to your Network Settings and you will want to look at your Network Adapters. Right-click on the M580 network adapter. Select Properties then select Internet Protocol Version 4 and select Properties again. You will want to enable the 'Use the Following IP address'. Change the IP Address to 90.0.0.2 and the subnet mask to 255.255.255.0. Close all windows and now you should be able to connect to your M580.

          If you are using Windows 10, you might also want to make sure that you have at least driver version 3.15 IE25.

           

          What is the maximum run length of Cat6 2D4P6IPV3B cable?

          The maximum run length of a Cat6 cable is 90 metres and an allowance for 10 metres of patch lead. In total with the patch lead the total run length is 100 metres. Clipsal cat6, UTP cable 2D4P6IPV3B  is sold in a 305 metre box.
          For further information please refer https://www.clipsal.com/Trade/Products/ProductDetail?catno=2D4P6IPV3B
          User-added image

          How is it possible to determine if an Enercept Meter is the Basic or Enhanced model?

          A System ID register located at addresses 30 (Integer) and 315 (Float) exists within the Enercept Meter. Reading that register will yield one of two values:
          A value of 15022 will be returned from the Enhanced Enercept model.
          A value of 15023 will be returned from the Basic Enercept model.

          Osisense XM_XMPC06C2941S701 specifications and how to order in 2015

          1) The XMPC06C2941S701 power switch is the "standard" XMPC06C2941 (available under logistic ref. XMPC06C2941AB in 2015, requesting to provide the fluid entries A, B, C, D definition) supplied with S701 specification.

          2) S701 specifications meaning
          • 1/2 gas fluid connection drilling in A (see attached file for fluid entries designation)
          • 1/4 gas fluid connection drilling in C
          3) How to order the XMPC06C2941S701 reference in 2015 : it has to be ordered under the following logistic reference XMPC06C2941S701AB (internal Schneider rule). Logistic situation : available, in stock in IDC Evreux France.

          Support on Buildings Management Systems and Pelco Security Solutions

           For support on Buildings Management Systems and Pelco Security Solutions please visit:  https://buildingskb.schneider-electric.com/

          Can the Modbus port / ports on the Compact 984 be configured for RS485 mode?

          No, the Compact 984 Modbus port / ports cannot be configured for RS485 mode. If this type of communications is needed, you need to use a RS232/RS485 converter that is externally powered.


          Note: The Compact product line was obsoleted in 2015 and repalced by the M340.

          Can the new Twido T2M I/O modules only be configured in TwidoSuite 2.20 and above?

          No.In TwidoSoft, all versions will need to be configured to the old module from the pick list and the same goes for all versions of TwidoSuite less than 2.20.

          Note: Twido was obsoleted in Dec. 2015 and was replaced with the M221 and SoMachine Basic. The M221 will support the TM2 I/O modules in SoMachine Basic.

          What is the replacement part number for the Quantum 140CPU53414A?

          The replacement part number is the Quantum 140CPU53414B. As of 2015 the 140CPU53414B controllers are obsolete due to parts obsolescence and it is recommended to go to the Quantum Unity based hardware.

          NOTE: The Quantum Unity based processors will be end of life on 12/31/18 and replaced with the M580 that is currently now being sold.


          User manual of the obsolete XUSLP type 4 safety light curtains

          Please find attached the user manual of the obsolete XUSLP type 4 safety light curtains, for body protection

          Are schematics available for APC products?

          Issue
          I would like schematics for my APC product.

          Product Line
          All products including but not limited to UPS, PDU, Cables

          Environment
          All products and serial ranges. 

          Cause

          I want to test or repair my product, or duplicate a particular product.


          Resolution
           
          APC does not distribute schematic drawings of products to the public. APC schematics contain proprietary information.
           
          Additionally, there are no user serviceable parts inside the UPS and disassembly or modification of the UPS voids all warranty agreements. Only internal APC staff and authorized service centers whose staff have undergone training for service of our products should attempt to service or repair an APC UPS. Distributing schematics of the UPS to the public would only serve untrained users to attempt to repair or to modify a product which could result in product failure or injury. For these reasons, APC chooses not to distribute schematic drawings and strongly advises against service of our products by untrained personnel.

          This policy is quite common among manufacturers of power electronic equipment. We do not distribute cable assembly schematics to the public. Do not attempt to manufacture your own UPS communications cables, or purchase non-APC brand UPS cables. Doing so could void the warranty of the connected APC device. APC authorizes CoastTec (formerly Coastal Business Machines) as an out-of-warranty UPS repair center in the United States. They can be reached on the web at https://coasttec.com/, or by phone at 1-410-521-1000. In other countries, please contact your local support for repair options.

          For further information contact APC using any of the methods listed here: https://www.apc.com/support/contact/index.cfm

          Release Notes for CitectSCADA 2015 Service Pack 1

          Issue
          The CitectSCADA 2015 Service Pack 1 includes several product updates and enhancements, providing improvements in stability, performance and functionality.

          PowerSCADA (PSE) 8.1 Service Pack 1 (uses the same release notes) was created as a special case to fix a customer issue and thus was never officially released for general public use. It allows PSE to use Citect patches.  In general it is a “Power-Build” version of Citect 750 Service Pack 1 created by Citect to serve the PSE specific customer. 

          Product Line
          PowerSCADA Expert 8.1 (CitectSCADA 7.5)

          Environment
          Service Pack

          Cause
          Incorporating new or modified features.

          Resolution
          The attached Release Notes for Service Pack 1 discusses the following topics:
          • What’s New in CitectSCADA 2015 SP1
          • Service Pack Installation
          • Service Pack Uninstall
          • Files changed in this Service Pack
          • Known Issues
          • Issues resolved in this Service Pack

          How to change the power sign on 5.2E, 6.2E, 5.3E,6.3E trip units for Powerpact H, J and L frame breaker?

          Issue:
          How to change the power sign on 5.2E, 6.2E, 5.3E,6.3E trip units for Powerpact H, J and L frame breaker?

          Product Line:
          Powerpact H, J and L

          Environment:
          5.2E, 6.2E, 5.3E,6.3E Micrologic trip units

          Cause:
          Power values reading negative.



          Resolution:
          The power sign can be changed through Modbus register, or with RSU software and UTA test kit STRV00910.

          RSU:
          Modify the Power sign using the RSU software and UTA Tester STRV00910, see link for free RSU download.
          https://www.schneider-electric.us/sites/us/en/support/product-support-resources/software-and-calculators/software/ltu-software-for-uta-tester.page

          By default, the Micrologic E trip unit signs as positive the powers running through the circuit breaker supplied from the top with loads connected from the underside. Circuit breakers powered from the underside must have the powers signed as negative. 

          In the Metering setup/Power sign window, select the power sign:
          • + The power running through the circuit breaker from top to bottom is
          counted positively.
          • - The power running through the circuit breaker from bottom to top is
          counted negatively.
          The default value of the powersign is +.


          MODBUS:
          Power Flow
          Sign 3316 3315 RW — — UINT 0–1 E
          Power flow sign
          0 = the active power flows from upstream (top) to downstream (bottom) (default).
          1 = the active power flows from downstream (bottom) to upstream (top).
          The power flow sign command (command code = 47240) configures the content of the power flow sign register.

          8000 7999 — — UINT 46240 E Command code = 46240
          8001 8000 — — UINT 12 E Number of parameters (bytes) = 12
          8002 8001 — — UINT 5121 E Destination = 5121 (0x1401)
          8003 8002 — — UINT 1 E 1
          8004
          8005
          8003
          8004 — — STRING — E Level 4 password (default value = ‘0000’ = 0x30303030)
          8006 8005 — — UINT 0–1 E
          Power flow sign
          0 = the active power flows from upstream (top) to downstream (bottom)
          (default)
          1 = the active power flows from downstream (bottom) to upstream (top).
           

          Change default WebX ports in ClearSCADA

          This article explains how the default WebX ports can be changed for the redesigned WebX interface in ClearSCADA 2015 R1 and later versions. The default ports are set to 85 for HTTP (non-secure) and 453 for HTTPS (secure) connections. This configuration can be altered from Microsoft Internet Information Services (IIS) Manager.

          To change the default ports do the following:

          1. Launch Internet Information Services (IIS) Manager on the machine hosting ClearSCADA Server.
          2. Locate the ClearSCADA site and click on Bindings.
          3. Select the connection you would like to edit and hit the Edit button.
          4. Type the desired port number and hit OK. Make sure the new port is vacant and can be accessed by the clients. Please do not set the same ports for WebX and the Original WebX. The appropriate SSL Certificate can also be selected for the secure port (HTTPS) at this stage.
          5. Restart the ClearSCADA site by clicking on Restart located in the Manage Website section.

          Keep in mind that the secure WebX port in ClearSCADA 2015 R1 is also being used by ClearSCADA Mobile if it is installed on the same machine. ClearSCADA Mobile uses port 443 by default in all ClearSCADA versions prior to 2015 R1 and in newer.

          Power Monitoring Expert (PME) 8.0 - Cumulative Update 1 (CU1)

          Issue

          Power Monitoring Expert 8.0 systems without Cumulative Update 1 (CU1) may experience the following issues:

          1. Potential for extremely slow on-board data log retrieval performance, risk of data loss if not managed before onboard data log is overwritten.  Only related to the following devices (CM3000, CM4000, PM800, Micrologic, Compact NSX) when multiple devices are attached with serial daisy chains (Direct or gateway).

          2. Report Subscriptions relative date ranges may not get processed correctly.

          3. Inability to use the VIP to log 3300 ACM data

          Product Line
          StruxureWare Power Monitoring Expert 8.0 - Base Edition, Data Center Edition, Healthcare Edition and Buildings Edition


          Resolution
          **Note: All DVDs shipped from the factory after January 4th, 2016 will include this CU1 - December 2015 on the DVD.  Any DVD's shipped prior will require this CU1 - December 2015 download.

          It is recommended to install PME8 CU1 for the following offers:
          • Power Monitoring Expert 8.0
          • Power Monitoring Expert 8.0 - Data Center Edition
          • Power Monitoring Expert 8.0 - Healthcare Edition
          • Power Monitoring Expert 8.0 - Buildings Edition

          It should be installed against the following install types:
          • Standalone Primary
          • Primary with Distributed Database Server (Does not need to be installed against Database Server itself)
          • Secondard Server
          • Engineering Client

          Install the attached update by following the procedure below:

          1. Extract the attached file 'PME_8.0_Cumulative_Update_1_Dec_2015.exe.zip'.
          2. Run the installation package.
          3. Follow the on-screen setup procedures and ensure that the verification of the system is successful.
          4. Once the configuration is complete, you may close setup window. The CU1 update is now installed.
           

          What Modbus parameters are available for port 1 on a Twido for programming?

          The Twido only supports one Modbus port parameter for programming.
           

          Baud Rate
          19,200
          Parity
          None
          Data Bits
          8
          Stop Bits
          1

          Note: The Twido line was obsoleted Dec. 2015 and replaced wit the M221 line. For more information on this contact local distributor or technical support.

          What does the +, -, and not equal mean when on-line with TwidoSuite?

          This shows the hardware and if it is configured, not configured or hardware not detected.



          Note: The Twido line has been obsolete since 2015 and replaced with the M221 product family, you can import your Twido project into SoMachine Basic and use the same I/O as long as it is the TM2 modules. For more questions contact your local distributor os Schneider sales office.

          eXL Hoist Change - 20154

          Issue:
          Is there any difference between the older generation and newer generation of the eXL Hoist controllers?

          Product Line:
          Wireless Joysticks - GIC Product

          Environment:
          US Product

          Cause:
          Product Characteristics

          Resolution:
          The eXL Hoist system was changed in late 2015 to incorporate a better battery than the older design.  Besides this change, there is no functional difference between the units.